![Alliance Laundry Systems D1528ENR3 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/alliance-laundry-systems/d1528enr3/d1528enr3_operation-and-maintenance-manual_2901525024.webp)
CFD902N_SVG
1
1.
Grease Injection Ports
Figure 47
Quarterly
NOTE: Disconnect power to the machine at its source
before performing the quarterly maintenance proce-
dures.
1.
Tighten door hinges and fasteners, if necessary.
2.
Tighten anchor bolts, if necessary.
3.
Verify that the drain motor shield is in place and secure, if so
equipped.
4.
Clean customer-supplied steam filter, where applicable. Refer
to
a. Turn off steam supply and allow time for the valve to
cool.
b. Unscrew cap.
c. Remove element and clean.
d. Replace element and cap.
H042I_SVG
2
1
1.
Cap
2.
Steam Filter Element
Figure 48
5.
Tighten motor mounting bolt locknuts and bearing bolt lock-
nuts.
6.
Vacuum lint from motor vents.
7.
Clean all electronic boards of moisture and dust with canned
air.
8.
Verify the insulation is intact on all external wires and that all
connections are secure. If bare wire is evident, call a service
technician.
9.
Clean inverter drive cooling fan blades [where applicable].
Annually
For 75, 90, 305 and 400 models only, replace the machine’s auto-
matic lubricator.
Care of Stainless Steel
• Remove dirt and grease with detergent and water. Thoroughly
rinse and dry after washing.
• Avoid contact with dissimilar metals to prevent galvanic cor-
rosion when salty or acidic solutions are present.
• Do not allow salty or acidic solutions to evaporate and dry on
stainless steel. Wipe clean of any residues.
• Rub in the direction of the polish lines or “grain” of the stain-
less steel to avoid scratch marks when using abrasive clean-
ers. Use stainless steel wool or soft, non-metal bristle brushes.
Do not use ordinary steel wool or steel brushes.
• If the stainless steel appears to be rusting, the source of the
rust may be an iron or steel part not made of stainless steel,
such as a nail or screw.
• Remove discoloration or heat tint from overheating by scour-
ing with a powder or by employing special chemical solu-
tions.
• Do not leave sterilizing solutions on stainless steel equipment
for prolonged periods of time.
• When an external chemical supply is used, ensure no siphon-
ing of chemicals occurs when the machine is not in use. High-
ly concentrated chemicals can cause severe damage to stain-
less steel and other components within the machine. Damage
of this kind is not covered by the manufacturer’s warranty.
Locate the pump and tubing below the machines’s injection
point to prevent siphoning of chemicals into the machine.
Maintenance
24
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT