© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
F8112301R3
18
2. Press Enter to continue.
j. Display shows “
no.SoAP. 9
” or “
SoAP. 9
”.
“
SoAP. 9
” enables liquid supply output
number 9 (if machine is equipped).
1. Press Temperature button to alter selection.
2. Press Enter to continue.
k. Display shows “
no.SoAP. 10
” or “
SoAP
.
10
”. “
SoAP
.
10
” enables liquid supply output
number 10 (if machine is equipped).
1. Press Temperature button to alter selection.
2. Press Enter to continue.
l. Display shows “
no.SoAP. 1
1” or“
SoAP.
11
”. “SoAP. 11” enables liquid supply output
number 11 (if machine is equipped).
1. Press Temperature button to alter selection.
2. Press Enter to continue.
m. Display shows “
no.SoAP. 12
” or “
SoAP
.
12
”. This option enables liquid supply output
number 12 (if machine is equipped).
1. Press Temperature button to alter selection.
2. Press Enter to continue.
100. Display shows “
Add
” or “
no Add
”. “
Add
” will
program a cool down, a timer stop or a soak
cycle. “
no Add
” will disable this option.
101. Press Temperature button to alter selection.
102. Press Enter to continue.
103. Display shows “
iS.tiLt.xx
” (xx = number of
attempts). This option programs the number of
times machine should attempt an intermediate
extract in the event that an out of balance
situation occurs.
104. Enter a value using the keypad. A value of 5 or
“
iS.tiLt.05
” is recommended.
105. Press Enter to continue.
106. Display shows “
ES.tiLt.xx
” (xx = number of
attempts). This option programs the number of
times machine should attempt a final extract in
the event that an out of balance situation occurs.
107. Enter a value using the keypad. A value of 10 or
“
ES.tiLt.10
” is recommended.
108. Press Enter to continue.
109. Display shows “
HYSt x
” (x = temperature
differential). This option programs the
temperature differential for supplemental heating
and temperature controlled water.
110. Enter a value using the keypad. A value of
5
°
C/9
°
F
is recommended.
111. Press Enter to continue.
112. Display shows “
bu =
” or “
no bu =
”. “
bu =
”
enables a buzzer sound at end of program,
“
no bu =
” disables the buzzer.
113. Press Temperature button to alter selection.
114. Press Enter to continue.
115. Display shows “
SP rPn
” or “
SP GF
”. This
option programs speed in RPM or G Force (G
Force is recommended).
116. Press Temperature button to alter selection.
117. Press Enter to continue.
118. Display shows “
no t
” or “
t
”. “
t
” enables viewing
the temperature on the display when the
Temperature button is pressed.
119. Press Temperature button to alter selection.
120. Press Enter to continue.
121. Display shows “
noACCL
” or “
ACCL
”. “
ACCL
”
enables the Rapid Advance feature.
122. Press Temperature button to alter selection.
123. Press Enter to continue.
124. Display shows “
noEnEr
” or “
EnEr
”. “
EnEr
”
enables the Stop button.
125. Press Temperature button to alter selection.
126. Press Enter to continue.
127. Display shows “
no ALAr
n
” or “
ALAr
n
”.
“
ALAr
n
” enables viewing various alarm codes
on the display in the event of a fault.
128. Press Temperature button to alter selection.
129. Press Enter to continue.
130. Display shows “
no.t .iHoLd
” or “
t .iHoLd
”.
“
t .iHoLd
” enables a timer hold feature for use in
conjunction with the liquid supply system.
131. Press Temperature button to alter selection.
132. Press Enter to continue.
NOTE: This feature is used when a single chemical
dispenser is feeding two machines and the
dispenser can only serve one machine at a time. If
one machine is being served, the dispenser opens a
busy relay connected to timer hold inputs. When a
second machine needs chemicals, the program
timer pauses and waits until busy relay is closed,
then proceeds with the chemical signals. If there is
www.groupdynamics-laundry.com