© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
F8112301R3
16
41. Display shows “
no i.9
” or “
i.9
”. “
i.9
” enables a
liquid supply flush valve. If enabled, the valve
activates for a predetermined time (refer to
Step 47
) after liquid supply injection signal. As
an alternative, this selection can be used as an
additional cold water inlet valve.
42. Press Temperature button to alter selection.
43. Press Enter to continue.
44. Display shows “
i.9 FluSH
” or “
i.9 Hard
”. “
i.9
FluSH
” selects a liquid supply flush valve and
“
i.9 Hard
” selects an additional cold water inlet.
45. Press Temperature button to alter selection.
46. Press Enter to continue.
NOTE: If “
i.9 HArd
” was selected, “
no i.r1
” will
display (proceed to Step 53), or if “
i.9 FluSH
” was
selected, “
FL t xx
” (xx=number of seconds) will
display.
47. Display shows “
FL t xx
”.
48. Using the keypad, input number of seconds the
liquid supply flush valve should open after each
chemical injection (15 seconds or “
FL t 15
”
recommended).
49. Press Enter to continue.
50. Display shows “
FL d xx
” (xx=number of
seconds).
51. Using the keypad, input the number of seconds
delay before “
i.9
” opens (15 seconds or
“
FL d 15
” recommended).
52. Press Enter to continue.
NOTE: During each chemical injection, the flush
valve (“
i.9
”) will turn on to flush chemicals. Each
time a chemical injection is called for, the PS40 will
wait for the time programmed in “
FL d
” and then
flush chemical drippage for time programmed in
“
FL t
”.
53. Display shows “
no i.r1
” or “
i.r1
”. “
i.r1
” enables
the optional water reuse valve 1.
54. Press Temperature button to alter selection.
55. Press Enter to continue.
56. Display shows “
no i.r2
” or “
i.r2
”. “
i.r2
” enables
the optional water reuse valve 2.
57. Press Temperature button to alter selection.
58. Press Enter to continue.
59. Display shows “no
i.r3
” or “
i.r3
”. “
i.r3
” enables
the optional water reuse valve 3.
60. Press Temperature button to alter selection.
61. Press Enter to continue.
62. Display shows “
no rP
” or “
rP
”. “
rP
” enables the
water recirculating pump.
63. Press Temperature button to alter selection.
64. Press Enter to continue.
65. Display shows “
no
d1
” or “
d1
”. “
d1
” enables
the drain valve number 1 (standard equipment).
66. Press Temperature button to alter selection.
67. Press Enter to continue.
68. Display shows “
no
d2
” or “
d2
”. “
d2
” enables
the optional drain valve number 2.
69. Press Temperature button to alter selection.
70. Press Enter to continue.
71. Display shows “
no rd1
” or “
rd1
”. “
rd1
” enables
the water reuse drain valve number 1.
72. Press Temperature button to alter selection.
73. Press Enter to continue.
74. Display shows “
no rd2
” or “
rd2
”. “
rd2
” enables
the water reuse drain valve number 2.
75. Press Temperature button to alter selection.
76. Press Enter to continue.
NOTE: If no hot water inlet valves were selected
earlier in preprogramming or configuration
process, computer will default to “
HEAt
” setting
and “
HEAt SYS
” will not be displayed.
77. Display shows “
HEAt SYS
”. This option cannot
be altered.
NOTE: All machines are capable of taking
advantage of the built-in “
Temperature
Controlled Water Fill
” feature of the PS40. This
mixes hot and cold water to best achieve
programmed temperature. Machines with
supplemental steam or electric heating can also
utilize this feature.
78. Press Enter to continue.
79. Display shows “
noHEAt
” or “
HEAt
”. “
HEAt
”
enables water inlet and supplemental heating
without using “
Temperature Controlled Water
Fill
” feature.
80. Press Temperature button to alter selection.
81. Press Enter to continue.
www.groupdynamics-laundry.com