Installation
23
801504
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3. Use the three screws from the envelope located in
the cylinder to attach the power cord wires to the
terminal block.
Figure 29
4. Tighten all screws and reinstall access cover
removed in step 1.
IMPORTANT: Failure to tighten these screws
firmly may result in wire failure at the terminal
block.
5. Secure the strain relief to the power cord, or
wires, where they enter the dryer cabinet.
6. Check the continuity of the ground connection
before plugging the cord into an outlet. Use an
acceptable indicating device connected to the
center grounding pin of the plug and the green
screw on the back of cabinet.
7. Reinstall access cover and screw.
Four-Wire Plug
Figure 30
1. Remove access cover from rear of dryer.
Figure 31
D286I
1
“L1” Terminal
2
Neutral Terminal
3
“L2” Terminal
1
3
2
D815I
1
Typical Four-Wire Receptacle
2
Power Cord – Not supplied with dryer
(Four-Wire)
3
Strain Relief Nut
4
Strain Relief
D695I
1
4
2
3