Introduction

5

70444901

Includes models with the following control suffixes:

EO – OPL electronic

RE –  reversing OPL electronic

Nameplate Location

The nameplate is located on the back of the machine 

and is programmed in the Control.

(Continued)

Gas

Steam/Thermal Oil

Electric

120 

Pound

CA120L
CA120N
CT120L
CT120N
CU120L
CU120N
DR120G2-BA120L
DR120G2-BA120N
DR120G2-BT120L
DR120G2-BT120N
DR120G2-BU120L

DR120G2-BU120N
HA120L
HA120N
HT120L
HT120N
HU120L
HU120N
IPD120G2-IT120N
IPD120G2-IT120L
SA120L
SA120N

ST120L
ST120N
SU120L
SU120N
UA120L
UA120N
UT120L
UT120N
UU120L
UU120N

CT120S
CT120T
CU120S
CU120T
DR120S2-BT120T
DR120S2-BU120S
DR120S2-BU120T
DR120S2-BT120S
HT120S
HT120T
HU120S

HU120T
IPD120S2-IT120S
IPD120S2-IT120T
ST120S
ST120T
SU120S
SU120T
UT120S
UT120T
UU120S
UU120T

Not Applicable

170 

Pound

CA170L
CA170N
CT170L
CT170N
CU170L
CU170N
DR170G2-BA170L
DR170G2-BA170N
DR170G2-BT170L
DR170G2-BT170N
DR170G2-BU170L

DR170G2-BU170N
HA170L
HA170N
HT170L
HT170N
HU170L
HU170N
IPD170G2-IT170N
IPD170G2-IT170L
SA170L
SA170N

ST170L
ST170N
SU170L
SU170N
UA170L
UA170N
UT170L
UT170N
UU170L
UU170N

CT170S
CT170T
CU170S
CU170T
DR170S2-BT170T
DR170S2-BU170S
DR170S2-BU170T
DR170S2-BT170S
HT170S
HT170T
HU170S

HU170T
IPD170S2-IT170T
IPD170S2-IT170S
ST170S
ST170T
SU170S
SU170T
UT170S
UT170T
UU170S
UU170T

Not Applicable

Содержание 70444901R3

Страница 1: ...y com Tumble Dryer OPL Electronic Control Refer to Page 3 for Model Identification Part No 70444901R3 July 2011 Keep These Instructions for Future Reference If this machine changes ownership this manu...

Страница 2: ......

Страница 3: ...des of Operation 10 Power up Mode 10 Idle Mode 10 Run Mode 10 Rapid Advance Mode 10 Pause Mode 10 Error Mode 10 Communication Mode 11 Cool Down Mode 11 End of Cycle Mode 11 Extended Tumble Mode 11 Rev...

Страница 4: ...Motor Test 32 Damper Motor Test 32 Reverse Motor Test 32 Production Test Cycle 33 To Enter Production Test Cycle 33 To Exit Production Test Cycle 33 Machine Errors 34 PDA Communications Error 34 Open...

Страница 5: ...0S IPD30S2 IT030S ST030S SU030S UT030S UU030S CHD30E2 CU030E CHD30E2 CT030E DR30E2 BT030E DR30E2 BU030E HT030E HU030E IPD30E2 IT030E ST030E SU030E UT030E UU030E 30 Pound Stacked CHD30STG2 CAT30L CHD30...

Страница 6: ...UT050S UT050T UU050S UU050T CT050E CU050E DR55E2 BT050E DR55E2 BU050E HT050E HU050E IPD50E2 IT050E ST050E SU050E UT050E UU050E 55 Pound CA055L CA055N CT055L CT055N CU055L CU055N HA055L HA055N HT055D...

Страница 7: ...120N UA120L UA120N UT120L UT120N UU120L UU120N CT120S CT120T CU120S CU120T DR120S2 BT120T DR120S2 BU120S DR120S2 BU120T DR120S2 BT120S HT120S HT120T HU120S HU120T IPD120S2 IT120S IPD120S2 IT120T ST120...

Страница 8: ...ill resume the cycle when the power recovers Communications The control has the ability to communicate with a PDA and a laptop with an IrDA device running the control software Devices such as PDAs and...

Страница 9: ...nd of Cycle Audio Enabled 5 seconds End of Cycle External Signal Enabled 5 seconds Clean Lint Screen Reminder Off Display Limit Errors Disabled Manual Diagnostics Enabled Manual Programming Enabled Re...

Страница 10: ...anage operation of the tumbler Refer to Figure 1 Figure 2 Figure 3 Figure 4 and Table 1 S Models H Models U Models B C and I Models NOTE The reversing feature is not available on all models TMB1345R F...

Страница 11: ...urn to Idle Mode when the control displays the main menu or clear an error message from the display STOP Press to pause a cycle while in Run Mode or abort a cycle if the control is in Pause Mode START...

Страница 12: ...g Run Mode Press Stop keypad to stop cycle and enter Pause Mode Control enters Pause Mode if loading or lint door opens Press Start to Rapid Advance Rapid Advance Mode If the Rapid Advance Option is e...

Страница 13: ...is opened or Stop keypad is pressed The control will then return to Idle Mode Extended Tumble Mode The Extended Tumble Mode has two portions The Anti Wrinkle Tumble is entered two minutes after the cy...

Страница 14: ...e time This time is taken from the machine cycles as they are programmed The Total Remaining Cycle Time begins to count down as soon as the cycle is started Time Dry Cycle In this type of cycle the co...

Страница 15: ...ypad to enter the displayed mode 6 To exit press the Back keypad The control will revert back to Idle Mode Manual Programming can only be turned on or off with an external device Refer to the appropri...

Страница 16: ...d to scroll through the Audit options Press the Start keypad Press the Start keypad to reset control Press the Start keypad to enter Diagnostic Tests Refer to Diagnostic Tests flowchart TMB1372R Press...

Страница 17: ...program 3 Press the Up or Down keypad to change the value of that option 4 Press Start to save the change NOTE Press the Back keypad to leave the option without saving any change 5 After pressing Sta...

Страница 18: ...ure Dry Target Moisture CXXS56 Segment 5 Reversing Enable Disable 10 Cool Down CXXCd1 Cool Down Temperature CXXCd2 Cool Down Time CXXCd3 Cool Down Segment Reversing Enable Disable 11 Reversing CXX r1...

Страница 19: ...a External Signal End of Cycle 1 0 oFF 1 on b External Signal End Of Cycle Duration seconds 5 1 120 7 Multi Segment Cycles 0 1 Enable 0 Disable 8 Advanced Moisture Dry Options 0 1 Enable 0 Disable 9 E...

Страница 20: ...ycle XX Material Type CXXtPt Cycle XX Time Past Target Prog Manual Programming on Enable oFF Disable tinE Time Dry Avto Auto Dry noist Moisture Dry 0 Cotton 1 Blend 2 Bedding 3 Delicate 4 Synthetic 5...

Страница 21: ...S23 Segment 2 Temperature CXXS24 Segment 2 Auto Dry Target Level CXXS25 Segment 2 Moisture Dry Target Level CXXS26 Segment 2 Reversing Enable Disable CXXS31 Segment 3 Enable Disable CXXS32 Segment 3 T...

Страница 22: ...arget Level CXXS46 Segment 4 Reversing Enable Disable CXXS51 Segment 5 Enable Disable CXXS52 Segment 5 Time CXXS53 Segment 5 Temperature CXXS54 Segment 5 Auto Dry Target Level CXXS55 Segment 5 Moistur...

Страница 23: ...versing Enable Disable CXX r1 Cycle Reversing Enable Disable CXX r2 Cycle Reversing Rotate Time CXX r3 Cycle Reversing Stop Time Cd Global Cool Down Cd 1 Cool Down Temperature continued continued cont...

Страница 24: ...2 Stop Time rEv 3 Advanced Reversing On off tEnp 1 Global Very Low Temperature tEnp 2 Global Low Temperature tEnp 3 Global Medium Temperature tEnp 4 Global High Temperature To enter a programming opt...

Страница 25: ...uration ESig External Signal nvLSEg Multi Segment Cycles on off ndryOP Advanced Moisture Dry Options Enable Disable Error Error Displays Avdio Global Audio Signal To enter a programming option press t...

Страница 26: ...7 Daylight Savings on off AIg Auto Ignite Retry diAgEn Manual Diagnostics on off t FC Temperature To enter a programming option press the Start keypad To exit press the BACK keypad continued rtC Real...

Страница 27: ...eypad to scroll through various options until the desired option is shown in the display Refer to the Audit Options List Table 2 for an explanation of the audit options available 2 Once the desired op...

Страница 28: ...s on the control For an explanation of the Factory Default Settings refer to Default Tumbler Settings How to Enter Manual Reset 1 Control must be in Manual Mode to start Refer to Entering the Manual M...

Страница 29: ...on each test read the appropriate description How to Exit Testing Feature Press the Back keypad The display will return to Idle Mode Table 3 Diagnostic Testing Mode Quick Reference Chart Display Diag...

Страница 30: ...mit Thermostat Status SL XX Stove High Limit Thermostat 1 Status SL2 XX Stove High Limit Thermostat 2 Status ddiP DIP Switch Status diCnAL ICM Alarm Status diCnrS ICM Reset Test dEALrn External Alarm...

Страница 31: ...lint door switch has to be closed or open for at least one second for the control to register the switch as closed or open NOTE Loading door must be closed while testing lint door To exit the Lint Doo...

Страница 32: ...the ICM reset will become active If the reset signal is active for a long enough period of time 4 seconds the ICM Lockout input will become active To reset the ICM stop the ICM Reset Test and then sta...

Страница 33: ...ermistor Temperature Test This option displays the temperature sensed at the thermistor in 5 F increments To start test control must be in the Testing Mode Refer to How to Enter Testing Feature at the...

Страница 34: ...t towards the total machine run time operation To exit Fan Motor Test press the Back keypad The control will return to the testing mode Damper Motor Test This option shows the damper motor running To...

Страница 35: ...ontrol will show When all keypads have been pressed the control will advance to next step after a one second delay or Loading Door Test The control will display the status of the loading door if door...

Страница 36: ...ight Alarms Menu Shorted Thermistor Error Any time the control senses a temperature greater than 210 4 F during an active cycle the control will enter the Cool Down portion of the cycle display this e...

Страница 37: ...he cycle will not start and all user inputs will be ignored If the error does clear the control will go back to its previous mode of operation When this error occurs the Airflow Switch 1 error counter...

Страница 38: ...with the value of switch 1 switch 2 and switch 3 on the DIP switch configuration If the result is an invalid setup the control will not enter Idle mode and instead enter Error Mode The control will ig...

Страница 39: ...and try again Time out Exceeded Communication error Re aim external device and try again Encryption Error Incorrect machine type Before downloading ensure data is for current machine type Invalid Wak...

Страница 40: ...round thermostat If problem persists replace control or thermostat ICM Lockout Alarm Active Rotation Sensor Error Check for broken or worn belts Make sure machine is not over loaded and check if rotat...

Страница 41: ...have its data read without using the keypad It may also be used to start and stop various diagnostic tests How to Begin Communications with An External Device The control will go blank and the displa...

Страница 42: ...Time Dry n a OFF 160 F 71 C 30 minutes 17 30 Min Low Time Dry n a OFF 140 F 60 C 30 minutes 18 30 Min No Heat Time Dry n a OFF n a 30 minutes 19 15 Min High Time Dry n a OFF 190 F 88 C 15 minutes 20...

Отзывы: