Machine Errors

35

70444901

Auto Ignition Retry (Gas Models 

Only)

If the Ignition Control Module (ICM) fails to ignite the 

gas valve the ICM will send an ICM Lockout Alarm to 

the control. When the control receives the ICM 

Lockout Alarm it will increment the ICM Lockout 

Alarm audit counter. When the error becomes fatal 

(user input needed to restart the machine) the control 

will increment the Heat Error audit counter and record 

the Heat Error in the Last Eight Alarms Menu.
If the ICM needs to be manually reset, when the 

control receives the ICM Lockout Alarm it will 

display the Cycle Stopped Menu with text prompting 
the user to press the Start (

) keypad to reset the 

ICM. The user can continue to reset the ICM until 

there are no more programmable retry attempts 

(factory default is 3) or the gas ignites. On machines 

equipped with an ICM that does not need to be 

manually reset, when the control receives the ICM 

Lockout Alarm it will turn the heat relay off for twenty 

(20) seconds and then turn it back on to try and ignite 

the gas. The control will continue to try and ignite the 

gas until there are no more programmable retry 

attempts (factory default is 3) or the gas ignites. If the 

ICM fails to ignite the gas on the last attempt the 

control will start the Cool Down portion of the cycle, 

display the heat error message and sound the audio 

signal. When the Cool Down portion of the cycle ends 

the control will continue to display the error message 

until power is cycled to the machine or a user presses 
the Back ( ) keypad.

Air Flow Switch Errors

The control will flag an Airflow Switch Error under 

several conditions. Airflow Switch Errors will be 

processed differently depending upon what state the 

machine was in when the error was detected.

Airflow Switch Sensed Closed While Not 
In Run Mode

If an airflow switch is sensed closed 30 seconds after 

entering Idle Mode, Pause Mode or End of Cycle 

Mode, the control will display an error message until 

power is cycled or the error clears. The cycle will not 

start and all user inputs will be ignored. If the error 

does clear, the control will go back to its previous 

mode of operation. When this error occurs the Airflow 

Switch 1 error counter will be incremented and the 

error will also be saved to the Last Eight Alarms 

Menu.

Airflow Switch Does Not Close After Cycle 
Started

If the airflow switch does not close within 5 seconds 

of the start/re-start of a cycle, the control will go to the 

Cool Down portion of the cycle, display an error 

message and sound the audio alarm. Once the Cool 

Down portion of the cycle ends, the control will 

continue to display the error message until the power 
is cycled to the machine or the Back ( ) keypad is 

pressed. When this error occurs, the Airflow Switch 2 

error counter will be incremented and the error will 

also be saved to the Last Eight Alarms Menu.

Airflow Switch Bounces During A 
Running Cycle

If the airflow switch is open for at least one second, 

the heat will be turned off and will remain off until the 

switch is observed closed for at least 5 seconds (it is 

flagged as an airflow switch bounce). If there are 5 

airflow switch bounces within 5 minutes the control 

will go to the Cool Down portion of the cycle, display 

an error message and sound the audio signal. When the 

Cool Down portion of the cycle ends, the control will 

continue displaying the error message until power is 
cycled or a user presses the Back ( ) keypad. When 

this error occurs, the Airflow Switch Bounce Error 

will be incremented and the error will also be saved to 

the Last Eight Alarms Menu. The Airflow Switch 

Bounce counter will be incremented for every instance 

of an airflow switch bounce.

Rotation Sensor Error

If the machine is equipped with a rotation sensor, the 

control will constantly monitor the input and calculate 

the cylinder’s rpm. If the rpm drops to zero while the 

cylinder is supposed to be spinning, the control will go 

to the Cool Down portion of the cycle. The control 

will display an error message and sound the audio 

signal. Once the Cool Down portion ends, the control 

will continue to display the error message until power 

is cycled to the machine. This error will increment the 

Rotation Sensor Error counter and will be saved in the 

Last Eight Alarms Menu.

Содержание 70444901R3

Страница 1: ...y com Tumble Dryer OPL Electronic Control Refer to Page 3 for Model Identification Part No 70444901R3 July 2011 Keep These Instructions for Future Reference If this machine changes ownership this manu...

Страница 2: ......

Страница 3: ...des of Operation 10 Power up Mode 10 Idle Mode 10 Run Mode 10 Rapid Advance Mode 10 Pause Mode 10 Error Mode 10 Communication Mode 11 Cool Down Mode 11 End of Cycle Mode 11 Extended Tumble Mode 11 Rev...

Страница 4: ...Motor Test 32 Damper Motor Test 32 Reverse Motor Test 32 Production Test Cycle 33 To Enter Production Test Cycle 33 To Exit Production Test Cycle 33 Machine Errors 34 PDA Communications Error 34 Open...

Страница 5: ...0S IPD30S2 IT030S ST030S SU030S UT030S UU030S CHD30E2 CU030E CHD30E2 CT030E DR30E2 BT030E DR30E2 BU030E HT030E HU030E IPD30E2 IT030E ST030E SU030E UT030E UU030E 30 Pound Stacked CHD30STG2 CAT30L CHD30...

Страница 6: ...UT050S UT050T UU050S UU050T CT050E CU050E DR55E2 BT050E DR55E2 BU050E HT050E HU050E IPD50E2 IT050E ST050E SU050E UT050E UU050E 55 Pound CA055L CA055N CT055L CT055N CU055L CU055N HA055L HA055N HT055D...

Страница 7: ...120N UA120L UA120N UT120L UT120N UU120L UU120N CT120S CT120T CU120S CU120T DR120S2 BT120T DR120S2 BU120S DR120S2 BU120T DR120S2 BT120S HT120S HT120T HU120S HU120T IPD120S2 IT120S IPD120S2 IT120T ST120...

Страница 8: ...ill resume the cycle when the power recovers Communications The control has the ability to communicate with a PDA and a laptop with an IrDA device running the control software Devices such as PDAs and...

Страница 9: ...nd of Cycle Audio Enabled 5 seconds End of Cycle External Signal Enabled 5 seconds Clean Lint Screen Reminder Off Display Limit Errors Disabled Manual Diagnostics Enabled Manual Programming Enabled Re...

Страница 10: ...anage operation of the tumbler Refer to Figure 1 Figure 2 Figure 3 Figure 4 and Table 1 S Models H Models U Models B C and I Models NOTE The reversing feature is not available on all models TMB1345R F...

Страница 11: ...urn to Idle Mode when the control displays the main menu or clear an error message from the display STOP Press to pause a cycle while in Run Mode or abort a cycle if the control is in Pause Mode START...

Страница 12: ...g Run Mode Press Stop keypad to stop cycle and enter Pause Mode Control enters Pause Mode if loading or lint door opens Press Start to Rapid Advance Rapid Advance Mode If the Rapid Advance Option is e...

Страница 13: ...is opened or Stop keypad is pressed The control will then return to Idle Mode Extended Tumble Mode The Extended Tumble Mode has two portions The Anti Wrinkle Tumble is entered two minutes after the cy...

Страница 14: ...e time This time is taken from the machine cycles as they are programmed The Total Remaining Cycle Time begins to count down as soon as the cycle is started Time Dry Cycle In this type of cycle the co...

Страница 15: ...ypad to enter the displayed mode 6 To exit press the Back keypad The control will revert back to Idle Mode Manual Programming can only be turned on or off with an external device Refer to the appropri...

Страница 16: ...d to scroll through the Audit options Press the Start keypad Press the Start keypad to reset control Press the Start keypad to enter Diagnostic Tests Refer to Diagnostic Tests flowchart TMB1372R Press...

Страница 17: ...program 3 Press the Up or Down keypad to change the value of that option 4 Press Start to save the change NOTE Press the Back keypad to leave the option without saving any change 5 After pressing Sta...

Страница 18: ...ure Dry Target Moisture CXXS56 Segment 5 Reversing Enable Disable 10 Cool Down CXXCd1 Cool Down Temperature CXXCd2 Cool Down Time CXXCd3 Cool Down Segment Reversing Enable Disable 11 Reversing CXX r1...

Страница 19: ...a External Signal End of Cycle 1 0 oFF 1 on b External Signal End Of Cycle Duration seconds 5 1 120 7 Multi Segment Cycles 0 1 Enable 0 Disable 8 Advanced Moisture Dry Options 0 1 Enable 0 Disable 9 E...

Страница 20: ...ycle XX Material Type CXXtPt Cycle XX Time Past Target Prog Manual Programming on Enable oFF Disable tinE Time Dry Avto Auto Dry noist Moisture Dry 0 Cotton 1 Blend 2 Bedding 3 Delicate 4 Synthetic 5...

Страница 21: ...S23 Segment 2 Temperature CXXS24 Segment 2 Auto Dry Target Level CXXS25 Segment 2 Moisture Dry Target Level CXXS26 Segment 2 Reversing Enable Disable CXXS31 Segment 3 Enable Disable CXXS32 Segment 3 T...

Страница 22: ...arget Level CXXS46 Segment 4 Reversing Enable Disable CXXS51 Segment 5 Enable Disable CXXS52 Segment 5 Time CXXS53 Segment 5 Temperature CXXS54 Segment 5 Auto Dry Target Level CXXS55 Segment 5 Moistur...

Страница 23: ...versing Enable Disable CXX r1 Cycle Reversing Enable Disable CXX r2 Cycle Reversing Rotate Time CXX r3 Cycle Reversing Stop Time Cd Global Cool Down Cd 1 Cool Down Temperature continued continued cont...

Страница 24: ...2 Stop Time rEv 3 Advanced Reversing On off tEnp 1 Global Very Low Temperature tEnp 2 Global Low Temperature tEnp 3 Global Medium Temperature tEnp 4 Global High Temperature To enter a programming opt...

Страница 25: ...uration ESig External Signal nvLSEg Multi Segment Cycles on off ndryOP Advanced Moisture Dry Options Enable Disable Error Error Displays Avdio Global Audio Signal To enter a programming option press t...

Страница 26: ...7 Daylight Savings on off AIg Auto Ignite Retry diAgEn Manual Diagnostics on off t FC Temperature To enter a programming option press the Start keypad To exit press the BACK keypad continued rtC Real...

Страница 27: ...eypad to scroll through various options until the desired option is shown in the display Refer to the Audit Options List Table 2 for an explanation of the audit options available 2 Once the desired op...

Страница 28: ...s on the control For an explanation of the Factory Default Settings refer to Default Tumbler Settings How to Enter Manual Reset 1 Control must be in Manual Mode to start Refer to Entering the Manual M...

Страница 29: ...on each test read the appropriate description How to Exit Testing Feature Press the Back keypad The display will return to Idle Mode Table 3 Diagnostic Testing Mode Quick Reference Chart Display Diag...

Страница 30: ...mit Thermostat Status SL XX Stove High Limit Thermostat 1 Status SL2 XX Stove High Limit Thermostat 2 Status ddiP DIP Switch Status diCnAL ICM Alarm Status diCnrS ICM Reset Test dEALrn External Alarm...

Страница 31: ...lint door switch has to be closed or open for at least one second for the control to register the switch as closed or open NOTE Loading door must be closed while testing lint door To exit the Lint Doo...

Страница 32: ...the ICM reset will become active If the reset signal is active for a long enough period of time 4 seconds the ICM Lockout input will become active To reset the ICM stop the ICM Reset Test and then sta...

Страница 33: ...ermistor Temperature Test This option displays the temperature sensed at the thermistor in 5 F increments To start test control must be in the Testing Mode Refer to How to Enter Testing Feature at the...

Страница 34: ...t towards the total machine run time operation To exit Fan Motor Test press the Back keypad The control will return to the testing mode Damper Motor Test This option shows the damper motor running To...

Страница 35: ...ontrol will show When all keypads have been pressed the control will advance to next step after a one second delay or Loading Door Test The control will display the status of the loading door if door...

Страница 36: ...ight Alarms Menu Shorted Thermistor Error Any time the control senses a temperature greater than 210 4 F during an active cycle the control will enter the Cool Down portion of the cycle display this e...

Страница 37: ...he cycle will not start and all user inputs will be ignored If the error does clear the control will go back to its previous mode of operation When this error occurs the Airflow Switch 1 error counter...

Страница 38: ...with the value of switch 1 switch 2 and switch 3 on the DIP switch configuration If the result is an invalid setup the control will not enter Idle mode and instead enter Error Mode The control will ig...

Страница 39: ...and try again Time out Exceeded Communication error Re aim external device and try again Encryption Error Incorrect machine type Before downloading ensure data is for current machine type Invalid Wak...

Страница 40: ...round thermostat If problem persists replace control or thermostat ICM Lockout Alarm Active Rotation Sensor Error Check for broken or worn belts Make sure machine is not over loaded and check if rotat...

Страница 41: ...have its data read without using the keypad It may also be used to start and stop various diagnostic tests How to Begin Communications with An External Device The control will go blank and the displa...

Страница 42: ...Time Dry n a OFF 160 F 71 C 30 minutes 17 30 Min Low Time Dry n a OFF 140 F 60 C 30 minutes 18 30 Min No Heat Time Dry n a OFF n a 30 minutes 19 15 Min High Time Dry n a OFF 190 F 88 C 15 minutes 20...

Отзывы: