14
505828
Exhaust System
IMPORTANT: Keep exhaust duct as short as
possible.
NOTE: Be certain old ducts are cleaned before
installing your new dryer.
For best drying results, recommended maximum length
of exhaust system is shown below.
To prevent backdraft when dryer is not in operation,
outer end of exhaust pipe must have a weather hood
with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least
30.5 cm (12") above the ground.
Exhaust Direction
The dryer can be exhausted to the outdoors through the
back, left, right or bottom of the dryer.
Dryer is shipped from factory ready for rear exhaust;
no kits required.
Exhausting the dryer through sides or bottom can be
accomplished by installing a DK1 Sales Accessory
(Directional Exhaust Kit 528P3) available as optional
equipment at extra cost.
D328IE0A
Q¢G aF4apm"d ¨^"¤ a
Number of
90° Elbows
Weather Hood Type
Recommended
Use only for short run installations
Maximum length of 10.2 cm (4") diameter rigid metal duct.
0
13.4 m (44 feet)
10.4 m (34 feet)
1
10.4 m (34 feet)
7.9 m (26 feet)
2
7.9 m (26 feet)
6.1 m (20 feet)
3
6.1 m (20 feet)
4.3 m (14 feet)
Maximum length of 10.2 cm (4") diameter flexible metal duct.
0
7.3 m (24 feet)
6.1 m (20 feet)
1
6.1 m (20 feet)
4.9 m (16 feet)
2
4.9 m (16 feet)
3.7 m (12 feet)
3
3.7 m (12 feet)
2.4 m (8 feet)
NOTE: Deduct 1.8 m (6') for each additional elbow.
D011IE2N
10.16 cm
(4")
10.16 cm
(4")
D011IE2O
6.35 cm
(2-1/2")