![Alliance Laundry Systems 505828 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/alliance-laundry-systems/505828/505828_installation-and-operation-instructions-manual_2901236015.webp)
505828
13
©F¨^"¤F¤aFhFm
Never install flexible duct in concealed spaces, such as
a wall or ceiling.
Exhaust System Materials
Exhaust duct must be 10.2 cm(4") in diameter having
no obstructions. Rigid metal duct is recommended.
Non-combustible semi-rigid flexible metal duct is
acceptable. Do not use plastic pipe or flexible plastic
pipe, because it contributes to poor drying performance
and collects lint, which can lead to a fire hazard.
DO NOT use sheet metal screws on exhaust pipe joints
or other fastening means which extend into the duct
that could catch lint and reduce the efficiency of the
exhaust system. Secure all joints with duct tape. Use as
few elbows as possible.
Make-Up Air Requirements
For proper operation it is important that you locate the
dryer in an area that has an ample amount of make-up
air to replace the amount exhausted by the dryer.
Energy efficient homes with low air infiltration rates
should be equipped with an air exchanger that can
accommodate on demand make-up air needs in the
home. These devices can be obtained through your
building contractor or building material suppliers.
A clothes dryer produces combustible lint.
To reduce the risk of fire and combustion
gas accumulation the dryer MUST be
exhausted to the outdoors.
W116
To reduce the risk of fire and the
accumulation of combustion gases, DO NOT
exhaust dryer air into a window well, gas
vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
of a building.
W045
To reduce the risk of fire, DO NOT use
plastic pipe or flexible plastic pipe to
exhaust the dryer.
W041
WARNING
DO
D314IE0B
DON'T
D315IE0A