CARE OF THE ORGAN 

 

Your Allen Digital Organ constitutes a major advance in long-term maintenance-free 
operation.  There are no regular maintenance procedures required and, therefore, no 
periodic maintenance schedules to be observed. 

 

Reasonable care will keep the instrument looking beautiful for years to come.  The wood 
surfaces may be cleaned using a soft cloth dampened with lukewarm water.  A mild 
solution of lukewarm water and furniture soap may be used to remove fingerprints, etc.  
Polish dry with a soft cloth. 

 

Do not use wax, sprays or oils on the finish.  Satin finished surfaces will take on a semi-
gloss appearance when waxed and will eventually become yellowed. If you need to 
“polish” the organ for a special event, use only a very high quality wood furniture polish.  

 

Keys and stops should be cleaned using two clean cloths.  Immerse one in clear, 
lukewarm water and wring it thoroughly damp dry.  Loosen the dirt with this cloth, then 
polish with the dry cloth.  Do not use soap or detergent on the keys or stops.   

 

To polish the clear music rack, a furniture wax polish can be sprayed on a dry cloth and 
rubbed on the front of the music rack.  Try to keep the wax off of the wood finishes.  This 
will keep the music rack most clear. 

 

Your Allen Organ not only faithfully reproduces the organ traditions of the past but also 
anticipates the innovations of the future.  Should you have questions that are not 
addressed in this manual, please do not hesitate to contact your local Allen Organ 
representative.  Welcome to the family of satisfied Allen Organ owners! 

 

 

BATTERY BACKUP SYSTEM 

 

The memory for the capture system on your MDS organ is sustained by a Lithium battery.  
This allows capture settings and related items to be retained in memory when the organ is 
switched off or unplugged.  Under normal circumstances, the Lithium battery should last for 
several years.  A built-in warning system will alert you when the battery becomes weak and 
needs to be replaced.  Have the Console Controller™ drawer open before the organ is turned 
on.  If there is a problem the window will display: 

 

                                                  

WARNING  ! !
Replace      Battery

 

for about six seconds after the organ is switched on.  Should the battery in your MDS organ 
require replacement, contact your local Allen authorized service representative.   
 
 

Содержание MDS-8

Страница 1: ...MDS 8 Copyright 1997 Allen Organ Company All Rights Reserved AOC P N 033 0094...

Страница 2: ...organs Only a radical technological breakthrough could improve upon the fine performance of Allen s solid state oscillator organs Such a breakthrough came in conjunction with the U S Space Program in...

Страница 3: ...of Stops 1 II Solo voices and Second Voices 7 III Artistic Registration 8 IV Transposer Setting Pistons 12 V Programmable Console Functions 13 VI MIDI Guide 14 VII Installation Voicing Care of the Or...

Страница 4: ...ntains a fraction and they are referred to as mutations Among these are the Nasard and Quinte 2 2 3 Tierce 1 3 5 and Quintfl te 1 1 3 Because they introduce unusual pitch relationships with respect to...

Страница 5: ...und e g flutes and principals or strings and principals In reed pipes a metal tongue vibrates against an opening in the side of a metal tube called a shallot The characteristic sounds of different ree...

Страница 6: ...lationships to the pedal being pressed Used to crown the Pedal principal chorus Posaune 16 Swell Expression A strong Pedal reed that lends strength and snarl to the Pedal line Can have Swell tremulant...

Страница 7: ...ound stop or mixture comprised of principal tones Each note played produces four distinct pitches at octave and fifth relationships to the key being pressed The Mixture IV should never be used without...

Страница 8: ...peroctave 2 An open metal stop that produces foundation tone at the 2 pitch level Mixture IV A compound stop of principal tones Four notes in octave and fifth relationships sound together when a singl...

Страница 9: ...rm sound Tremulants Full When activated along with one or more of the organ s tremulants this control causes the tremulants to become much deeper in their oscillation than normal classical tremulants...

Страница 10: ...the Great and Pedal divisions can be changed using the Classical Voicing Gt Pd control As in the Swell division the second voices in the Great and Pedal divisions are accessed from stop tablets Certai...

Страница 11: ...bination was used widely in Baroque organ music but it is just as appropriate for some modern music Useful variations of the Cornet may be achieved by eliminating the 4 the 2 or both When choosing sto...

Страница 12: ...registration In creating registrations of your own remember these three simple rules 1 Seek tonal contrast between solo and accompaniment 2 Be sure the solo is louder than the accompaniment 3 Choose...

Страница 13: ...ensemble tones An Hautbois for example is usually a solo stop The various Trumpets Clairons Bassons etc are usually ensemble voices that add brilliance power and incisiveness to the sound If you have...

Страница 14: ...registrations avoid the temptation to rely constantly on one or two 16 stops and a coupler Please note that the softest stops and flute mutations are normally not used with ensembles FULL ORGAN Due t...

Страница 15: ...e stanza that leads into the key one half step above the key in which the hymn is written If the hymn is already in a fairly high key it may be preferable to play the first few stanzas with the Transp...

Страница 16: ...his is the default normal mode MIDI volume information is transmitted from each division on the MIDI channel assigned to that division Swell MIDI data is transmitted on MIDI Channel 1 Great on Channel...

Страница 17: ...ess General Piston 3 The middle four lights of the Swell expression indicator will flash indicating that the organ is now in Swell Volume mode D To select No Expression press General Piston 4 The top...

Страница 18: ...Set piston and then pressing the Cancel piston VI Music Memory The MDS 8 features Allen s Music Memory a selection of pre recorded demonstration pieces in a variety of tonal combinations and musical s...

Страница 19: ...I can send information to other MIDI devices e g synthesizers or sequencers and can play those devices simultaneously or record information to be played back later Allen organs incorporate a complete...

Страница 20: ...I capable Allen Organ consoles may be connected to a variety of MIDI devices A diagram for connecting the Allen organ to a variety of MIDI devices can be found at the end of this section of the manual...

Страница 21: ...to change the settings of MIDI sound modules or synthesizers which are connected to the organ Please consult the Console Controller guide and the owner s manual of your MIDI device s for more informa...

Страница 22: ...xternal speakers make sure they are not later used for storage closets Placing sound absorbent materials robes flowers papers etc will only damage the organs sound quality REVERBERATION The Digital Re...

Страница 23: ...to the family of satisfied Allen Organ owners BATTERY BACKUP SYSTEM The memory for the capture system on your MDS organ is sustained by a Lithium battery This allows capture settings and related item...

Страница 24: ...h are designed to provide reasonable protection against such interference in a residential installation Should this equipment cause interference to radio communications the user at his own expense wil...

Страница 25: ...MDS 8 Copyright 1997 Allen Organ Company All Rights Reserved AOC P N 033 0094 1...

Страница 26: ...organs Only a radical technological breakthrough could improve upon the fine performance of Allen s solid state oscillator organs Such a breakthrough came in conjunction with the U S Space Program in...

Страница 27: ...of Stops 1 II Solo voices and Second Voices 7 III Artistic Registration 8 IV Transposer Setting Pistons 12 V Programmable Console Functions 13 VI MIDI Guide 14 VII Installation Voicing Care of the Or...

Страница 28: ...ntains a fraction and they are referred to as mutations Among these are the Nasard and Quinte 2 2 3 Tierce 1 3 5 and Quintfl te 1 1 3 Because they introduce unusual pitch relationships with respect to...

Страница 29: ...und e g flutes and principals or strings and principals In reed pipes a metal tongue vibrates against an opening in the side of a metal tube called a shallot The characteristic sounds of different ree...

Страница 30: ...ing pressed Used to crown the Pedal principal chorus Posaune 16 Swell Expression A strong Pedal reed that lends strength and snarl to the Pedal line Can have Swell tremulant Trompete 8 Clear Pedal ree...

Страница 31: ...ote played produces four distinct pitches at octave and fifth relationships to the key being pressed The Mixture IV should never be used without stops of lower pitches The Mixture IV is typically adde...

Страница 32: ...ompound stop of principal tones Four notes in octave and fifth relationships sound together when a single key is depressed As pitches progress upward they break back to the next lower octave or fifth...

Страница 33: ...ontroller will be activated See Console Controller Guide Tremulants Full When activated along with one or more of the organ s tremulants this control causes the tremulants to become much deeper in the...

Страница 34: ...the Great and Pedal divisions can be changed using the Classical Voicing Gt Pd control As in the Swell division the second voices in the Great and Pedal divisions are accessed from stop tablets Certai...

Страница 35: ...bination was used widely in Baroque organ music but it is just as appropriate for some modern music Useful variations of the Cornet may be achieved by eliminating the 4 the 2 or both When choosing sto...

Страница 36: ...4 Play solo on Swell These few combinations demonstrate basic techniques of solo registration In creating registrations of your own remember these three simple rules 1 Seek tonal contrast between solo...

Страница 37: ...pes as compared to principals The Reed Chorus includes those reed tones designed to be used in the ensemble buildup Not all reed voices are ensemble tones An Hautbois for example is usually a solo sto...

Страница 38: ...in bringing clarity to the pedal line especially on softer registrations avoid the temptation to rely constantly on one or two 16 stops and a coupler Please note that the softest stops and flute muta...

Страница 39: ...e key one half step above the key in which the hymn is written If the hymn is already in a fairly high key it may be preferable to play the first few stanzas with the Transposer set down one half or o...

Страница 40: ...available features to play the instrument The organ is capable of all traditional organ functions without the use of the Console Controller system This control system provides additional flexibility...

Страница 41: ...keying information allowing one device to sense which keys have been played on another device This means an organ equipped with MIDI can send information to other MIDI devices e g synthesizers or sequ...

Страница 42: ...is an industry wide standard today s MIDI instruments will be compatible with tomorrow s MIDI innovations II CONNECTING THE ALLEN ORGAN TO OTHER MIDI DEVICES The MIDI capable Allen Organ consoles may...

Страница 43: ...l 2 Pedal Channel 3 MIDI Program Change Messages are transmitted from the organ s General Pistons on MIDI Channel 8 These program change messages can be used to change the settings of MIDI sound modul...

Страница 44: ...ts are normally a part of installation and once done should not require changes unless the instrument is moved to a new location or major changes are made to the room the organ resides in Bass frequen...

Страница 45: ...the clear music rack a furniture wax polish can be sprayed on a dry cloth and rubbed on the front of the music rack Try to keep the wax off of the wood finishes This will keep the music rack most clea...

Страница 46: ...dance with the instruction manual may cause interference to radio communications It has been type tested and found to comply with the limits for a Class B Computing Device in accordance with the speci...