64
Rockwell Automation Publication PFLEX-AP005B-EN-P - May 2019
Chapter 2
Analog Speed Follower and Preset Speed
Table 39 - PowerFlex 700 to PowerFlex 750-Series Drive (with optional I/O module)
IMPORTANT
Shaded table cells indicate factory-set default settings. Please verify
these settings if the drive is not new or a ‘set to factory defaults’ was
never performed.
PowerFlex 700 Drive Parameters
PowerFlex 750-Series Drive Parameters
(2)
No.
Name
Value
No.
Name
Value
41
Motor NP Volts
460
25
Motor NP Volts
460
42
Motor NP Amps
1.6
26
Motor NP Amps
1.6
43
Motor NP Hertz
60
27
Motor NP Hertz
60
44
Motor NP rpm
1785
28
Motor NP rpm
1785
45
Motor NP Power
1
30
Motor NP Power
1
Mtr NP Power
Mtr NP Pwr
46
Motor NP Power Units
0-Hp
29
Units
0-Hp
53
Motor Cntl Sel
0-Sensrls Vect
35
Motor Ctrl Mode
1-Induction SV
79
Speed Units
0-Hz
300
Speed Units
0-Hz
81
Minimum Speed
0.0
522
(3)
Min Fwd Speed
0.0
523
(3)
Min Rev Speed
0.0
82
Maximum Speed
60.0
520
(3)
Max Fwd Speed
Motor NP Hz/rpm x 1
521
(3)
Max Rev Speed
Motor NP Hz/rpm x -1
90
(1)
Speed Ref A Sel
Analog In 2
545
(1)
Spd Ref A Sel
Port 0 Ref
93
(1)
Speed Ref B Sel
Preset Speed 1
550
(1)
Spd Ref B Sel
Speed Ref B Stpt
91
(1)
Speed Ref A Hi
Max Speed (P82)
547
(1)
Spd Ref A AnlgHi
Max Fwd Spd (P520)
92
(1)
Speed Ref A Lo
0.0
548
(1)
Spd Ref A AnlgLo
0.0
101
Preset Speed 1
5 Hz/150 rpm
571
Preset Speed 1
1/12 x (P27 or P28)
102
Preset Speed 2
10 Hz/300 rpm
572
Preset Speed 2
1/6 x (P27 or P28)
103
Preset Speed 3
20 Hz/600 rpm
573
Preset Speed 3
1/3 x (P27 or P28)
104
Preset Speed 4
30 Hz/900 rpm
574
Preset Speed 4
1/2 x (P27 or P28)
105
Preset Speed 5
40 Hz/1200 rpm
575
Preset Speed 5
2/3 x (P27 or P28)
106
Preset Speed 6
50 Hz/1500 rpm
576
Preset Speed 6
5/6 x (P27 or P28)
107
Preset Speed 7
60 Hz/1800 rpm
577
Preset Speed 7
(P27 or P28)
140
Accel Time 1
10.0
535
Accel Time 1
10.0
141
Decel Time 1
10.0
537
Decel Time 1
10.0
322
Analog In 1 Hi
10.0
261
Anlg In0 Hi
10.0
323
Analog In 1 Lo
0.0
262
Anlg In0 Lo
0.0
361
Digital Input 1
8-Run Forward
164
DI Run Forward
Port 0 (P220) Input 1
362
Digital Input 2
9-Run Reverse
165
DI Run Reverse
Port 0 (P220) Input 2
364
Digital Input 4
15-Speed Sel 1
173
DI Speed Sel 0
Port 0 (P220) Input 3
365
Digital Input 5
16-Speed Sel 2
174
DI Speed Sel 1
Port 0 (P220) Input 4
366
Digital Input 6
17-Speed Sel 3
175
DI Speed Sel 2
Port 0 (P220) Input 5
(1) These default selections will vary between PowerFlex drive models and applications. Set these parameters to your specific application needs.
(2) The optional I/O module is installed in slot 4.
(3) The PowerFlex 750-Series drive offers parameters for speed direction (forward and reverse) that are not available in the PowerFlex 700 series.
‘P’ in all parentheses is an abbreviation for Parameter.
TIP
For best possible settings, perform an auto-tune (Rotate Tune) on the
connected motor to pair the motor to the drive.
Содержание Rockwell Automation PowerFlex 700 Series
Страница 1: ...PowerFlex 700 Drives to PowerFlex 750 Series Drives Migration Guide OriginalInstructions...
Страница 4: ...4 Rockwell Automation Publication PFLEX AP005B EN P May 2019 Table of Contents Notes...
Страница 54: ...54 Rockwell Automation Publication PFLEX AP005B EN P May 2019 Chapter 1 Drive Selection Considerations Notes...
Страница 71: ......