16
Rockwell Automation Publication PFLEX-AP005B-EN-P - May 2019
Chapter 1
Drive Selection Considerations
Table 9 - PowerFlex 700 Drive to PowerFlex 750-Series Drive Conversions
TIP
Voltage rating is 480V AC for all the drives that are listed.
PowerFlex 700 Drive
(1)
PowerFlex 750-Series Drive Conversion
(2)
20B
Amps
HP
(ND)
Frame
Height
mm,
(in.)
Width
mm,
(in.)
Depth
mm,
(in.)
20F/
20G
Amps
HP
(ND)
Frame
Height
mm,
(in.)
Width
mm,
(in.)
Depth
mm,
(in.)
1P1
1.1
0.5
0
336
(13.22)
110
(4.33)
200
(7.87)
2P1
2.1
1.0
0
2P1
2.1
1
2
424.5
(16.71)
134.5
(5.29)
212
(8.34)
3P4
3.4
2.0
0
3P4
3.4
2
2
5P0
5.0
3
0
5P0
5.0
3
2
8P0
8.0
5
0
8P0
8.0
5
2
011
11
7.5
0
011
11
7.5
2
014
14
10
1
336
(13.22)
135
(5.31)
200
(7.87)
014
14
10
2
022
22
15
1
022
22
15
2
027
27
20
2
342.5
(13.48)
222
(8.74)
200
(7.87)
027
27
20
3
454
(17.87)
190
(7.48)
212
(8.34)
034
34
25
2
034
34
25
3
040
40
30
3
517.5
(20.37)
222
(8.74)
200
(7.87)
040
40
30
3
052
52
40
3
052
52
40
4
474
(18.66)
222
(8.74)
212
(8.34)
065
65
50
3
065
65
50
4
077
77
60
4
759
(29.88)
220
(8.66)
202
(7.95)
077
77
60
5
555
(21.85)
270
(10.63)
212
(8.34)
096
96
75
5
644.5
(25.37)
309
(12.16)
275.5
(10.84)
096
96
75
5
125
125
100
5
125
125
100
6
665.5
(26.2)
308
(12.12)
346.5
(13.64)
156
156
125
6
850
(33.46)
(3)
404
(15.9)
275.5
(10.84)
156
156
125
6
180
180
150
6
186
186
150
6
248
248
200
6
248
248
200
6
292
292
250
7
1499
(59)
514.5
(20.25)
407 (16)
302
302
250
7
875
(34.44)
430
(16.92)
350
(13.77)
325
325
250
7
361
361
300
7
365
365
300
8
2374
(93.46)
758
(29.84)
889 (35)
361
361
300
7
415
415
350
8
415
415
350
7
477
477
400
7
481
481
400
8
485
485
400
8
(4)
2453
(96.57)
600
(23.62)
800
(31.49)
(5
)
535
535
450
8
1016
(40)
545
545
450
8
(4)
600
600
500
8
617
617
500
8
(4)
730
730
600
9
740
740
650
8
(4)
875
875
700
10
1268
(49.92)
889 (35)
960
960
800
9
(4)
2453
(96.57)
1200
(47.24)
800
(31.49)
(5
)
(1) All dimensions are IP20, NEMA/UL Type 1 unless specified otherwise.
(2) All dimensions are IP20, NEMA/UL Open type unless specified otherwise.
(3) Height dimension shown for a drive mounted in a cabinet; height dimension is 976.5 mm with required junction box if not cabinet-mounted.
(4) Frame enclosure is IP20, NEMA/UL Type 1 MCC style.
(5) The depth can be either 600 mm or 800 mm for 20G, frame 8, 9, and 10 depending on enclosure code.
Содержание Rockwell Automation PowerFlex 700 Series
Страница 1: ...PowerFlex 700 Drives to PowerFlex 750 Series Drives Migration Guide OriginalInstructions...
Страница 4: ...4 Rockwell Automation Publication PFLEX AP005B EN P May 2019 Table of Contents Notes...
Страница 54: ...54 Rockwell Automation Publication PFLEX AP005B EN P May 2019 Chapter 1 Drive Selection Considerations Notes...
Страница 71: ......