PowerFlex 20-HIM-A6 and 20-HIM-C6S HIM 
(Human Interface Module)

Firmware Revisions FRN 1.xxx - 2.xxx

User Manual

Original Instructions

Содержание PowerFlex 20-HIM-A6

Страница 1: ...PowerFlex 20 HIM A6 and 20 HIM C6S HIM Human Interface Module Firmware Revisions FRN 1 xxx 2 xxx User Manual OriginalInstructions ...

Страница 2: ...information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited Throughout this manual when necessary we use notes to make you aware of safety considerations Labels may also be on or inside the equipment to provide specific precautions WARNING Identifies informati...

Страница 3: ...t 12 Imported a diagram of the PowerFlex 755T series drive 16 Added a note to the Process Screen section 29 Added a note to the Creating a User Defined Drive Peripheral Name section 37 Added a noteto the Customizing the Process Screen section 38 Replaced password with access code except in references to user interface elements 50 61 Added a note to the Updating the HIM Firmware or Language section...

Страница 4: ...4 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Summary of Changes Notes ...

Страница 5: ...12 Chapter2 InstallingtheHIM Installing the 20 HIM A6 HIM 14 In the Drive HIM Bezel 14 Using Drive Port 2 Connection for Hand Held Operation 16 In a Remote Mount HIM Bezel 20 HIM B1 17 Installing the 20 HIM C6S HIM 18 Removing the HIM 21 Chapter3 HIMComponents HIM Keypad 23 Soft Keys 23 Navigation and Number Keys 24 Single function Keys 25 LCD Display Elements 26 Status Bar 26 Data Area 26 Soft Ke...

Страница 6: ...t Parameter Access Method 44 Alternate Linear List Access Method 45 Viewing Clearing Drive Faults or Alarms 46 Viewing Peripheral Diagnostic Items 47 Viewing Clearing Peripheral Events 48 Checking Drive and Peripheral Firmware Revisions 49 Using the CopyCat Function 50 Creating CopyCat Files 50 Renaming CopyCat Files 51 Deleting CopyCat Files 53 Changing PowerFlex 750 Series Drive Parameter Associ...

Страница 7: ... Publication 20HIM UM001E EN P May 2017 7 Table of Contents AppendixA Specifications Communications 67 Electrical 67 Mechanical 67 Environmental 67 Regulatory Compliance 68 AppendixB HIMParameters Parameter List 69 Index ...

Страница 8: ...8 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Table of Contents Notes ...

Страница 9: ... and xxx is the minor revision number Rockwell Automation Support Rockwell Automation offers support services worldwide with over 75 sales and support offices over 500 authorized distributors and over 250 authorized systems integrators located through the United States alone In addition Rockwell Automation representatives are in every major country in the world Local Product Support Contact your l...

Страница 10: ...lication 20B UM001 InformationoninstallingandprogrammingPowerFlex700standardcontrol andvector control Series Adrives andPowerFlex700 vector control Series B drives PowerFlex 700 Series B User Manual publication 20B UM002 PowerFlex 70 700 Reference Manual publication PFLEX RM001 PowerFlex 70 Enhanced Control and 700 Vector Control Reference Manual publication PFLEX RM004 PowerFlex 700H Installation...

Страница 11: ...configure and monitor the drive and its connected peripherals Better keypad touch response and improved tactile feel to provide more gratifying error free data entry More intuitive access and new menu structures that increase HIM operating efficiency Simplified custom name assignments for drive peripherals for example Pump 1 to reduce required key presses Topic Page HIM Types 11 Features 11 Compat...

Страница 12: ...lex 755TL drives PowerFlex 755TR drives PowerFlex 755TM common bus inverters PowerFlex 755TM bus supplies PowerFlex 70 drives with standard or enhanced control PowerFlex 700 drives with standard or vector control PowerFlex 700H drives PowerFlex 700S drives with Phase I or Phase II control PowerFlex 700L drives with 700 vector control or 700S control PowerFlex 700AFE Active Front End PowerFlex Digi...

Страница 13: ... the HIM There are two types of enhanced PowerFlex 7 Class HIM NEMA Type 1 catalog number 20 HIM A6 Remote mount NEMA Type 4X 12 catalog number 20 HIM C6S which also includes a 1202 C30 interface cable for connection to the drive Topic Page Installing the 20 HIM A6 HIM 14 Installing the 20 HIM C6S HIM 18 Removing the HIM 21 20 HIM A6 HIM 20 HIM C6S HIM ...

Страница 14: ...t long 20 HIM H10 cable For applications requiring the HIM to be located remotely the HIM can be installed in a remote mount HIM bezel catalog number 20 HIM B1 in a suitable location The 20 HIM B1 remote mount HIM bezel includes a 3 m 9 8 ft long 1202 C30 cable In the Drive HIM Bezel PowerFlex750 SeriesIP20 NEMA ULOpenTypeDrives Place the HIM into the drive HIM bezel by inserting it straight back ...

Страница 15: ...commended tools Screwdriver 6 4 mm 0 25 in flat or T20 Hexalobular Hex socket 7 mm 2 Place the HIM into the drive HIM bezel by inserting it straight back into the top of the bezel and then sliding it down into the base of the bezel onto the mating connector as shown on page 14 3 Replace the cover and the fasteners 4 Tighten all screws and nuts to the recommended torque of 0 68 N m 6 0 lb in 2x M4 ...

Страница 16: ...the cable into DPI Port 02 near the bottom of the drive control pod PowerFlex750 SeriesDrive Attach a 20 HIM H10 cable to the bottom of the HIM Then plug the other end of the cable into Port 2 near the bottom of the drive control pod PowerFlex 755T drive shown with cover removed Splitter Cable 1 m 3 28 ft long 20 HIM A6 HIM Cradle Connector DPI Port 02 PE PE 20 HIM A6 HIM 20 HIM H10 Cable 1 m 3 28...

Страница 17: ...IM B1 1 If the remote mount HIM bezel is not mounted see the HIM Bezel Installation Instructions publication 20HIM IN002 for mounting details 2 Route the 3 m 9 8 ft long 1202 C30 bezel cable included with the 20 HIM B1 remote mount HIM bezel to the drive 3 Connect the bezel cable to the DPI Port 2 on the drive as shown on page 16 for a PowerFlex 750 Series drive or a PowerFlex 7 Class drive Port 2...

Страница 18: ...202 Hxx extension cable or 1202 CBL KIT 100M cable kit However a cable distance greater than 30 m 98 4 ft is not CE compliant PowerFlex 755 drive shown without HIM in drive HIM bezel 20 HIM B1 Remote Mount HIM Bezel 3 m 9 8 ft long 1202 C30 bezel cable included with 20 HIM B1 remote mount HIM bezel Distances can be increased up to 75 m 246 ft 1 1 To increase this distance use one of the following ...

Страница 19: ...1 provided with the 20 HIM C6S HIM includes a drilling pattern and mounting instructions to assist with HIM installation 93 0 3 66 25 0 0 98 3 0 m 9 8 ft long 1202 C30 cable included with 20 HIM C6S HIM 1202 H03 0 3 m 0 98 ft long 1202 H10 1 0 m 3 28 ft long 1202 H30 3 0 m 9 80 ft long 180 0 7 08 1202 Hxx Extension Cable supplied separately and only needed if required distance exceeds 1202 C30 Cab...

Страница 20: ...IM C6S HIM 2 Peel the protective film from the gasketed surface on the back of the HIM IMPORTANT Adhesive coated gasket is designed for one time only installation 67 0 2 63 60 0 2 36 77 0 3 03 77 0 3 03 59 2 32 Ø 19 1 0 75 Ø 4 8 0 19 Dimensions are in millimeters and inches Front View 0 68 N m 6 0 lb in 2 3 4 5 6 7 Mounting Panel ...

Страница 21: ...e drive 9 Connect the HIM cable to the DPI Port 2 on the drive as shown on page 16 for a PowerFlex 750 Series drive or a PowerFlex 7 Class drive Removing the HIM Remove the HIM from the drive HIM bezel or the remote mount HIM bezel in reverse order of how it was installed ATTENTION Risk of injury or equipment damage exists If the HIM cable or remote mount HIM bezel cable is disconnected from DPI P...

Страница 22: ...22 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Chapter 2 Installing the HIM Notes ...

Страница 23: ... on the HIM are located at the top of the keypad and highlighted below Depending on the screen being displayed or the data entry mode being used a soft key name and its function changes When a dynamic soft key up to a maximum of five keys is active its present function and corresponding Soft Key Label Figure 3 is shown at the bottom of the HIM screen For a list of possible soft keys their names an...

Страница 24: ...he five gray number keys 0 1 3 7 and 9 are used only to enter their respective numeric value Multi function Key Name Function 2 Down Arrow Enters the numeric value 2 Scrolls down to select an item 4 Left Arrow Enters the numeric value 4 Scrolls left to select an item 5 Enter Enters the numeric value 5 Displays the next level of a selected menu item Enters new values Performs intended actions 6 Rig...

Страница 25: ... only its dedicated function Single function Key Name Function Start Starts the drive 1 1 During drive Start Up these keys are temporarily inactive Folders Accesses folders for parameters diagnostics memory functions preferences and other tasks 1 Controls Accesses jog direction auto manual andother control functions Stop Stops the drive or clears a fault This key is always active This key is contr...

Страница 26: ...d host drive Stopped Status Text Indicates present host drive operating status Text flashes when a faultis present 0 00 Hz Feedback Indicates drive output feedback for example Hz RPM amps etc AUTO MAN Mode Indication Indicates Auto or Manual HIM status Alarm Indication Bell icon indicates that an alarm is present F or R not shown Rotation Indication Indicates Forward or Reverse direction of host d...

Страница 27: ...s an entire text string DisplaystheSelectActionpopupboxusedtocleartheselectedfault alarmorevent ortheentirefault alarm or event queue DEL Delete Deletes a highlighted character EDIT Edit Accesses a displayed parameter to edit Accesses the Edit Process Display screen END End Displays the end least recent fault alarm or event in a queue Scrolls to the end lineof data on the Device Version informatio...

Страница 28: ...splays the top most recent fault alarm or event in a queue Scrolls to the top line of data on the Device Version information screen UPPER Upper Displays the upper 16 bits bits 16 31 of a 32 bit Bit type parameter VIEW View Toggles between select screens and views Displays the time stamp screen from a fault alarm or event queue screen ZONES Zones Displays the Select Time Zone screen Soft Key Label ...

Страница 29: ...ing parameters can be changed See Customizing the Process Screen on page 38 for details ProcessScreenSoftKeys Label Name Function ESC Escape Toggles between the Status and Process Display screens Language Icon Directly accesses the Select Language To Use screen REF Reference Enters the speed reference for the Host Drive PAR Parameter Number Directly accesses a parameter for the device on selected ...

Страница 30: ...ction ESC Escape Deactivates the Control Screen and reverts back to the previous screen Label Key Function JOG Jogs the host drive REF Decreases the speed reference for the host drive HELP Displays Rockwell Automation Drives Technical Support direct phone number website address and email address REV Sets the direction to reverse for the host drive EDIT REF Allows direct data entry of the speed ref...

Страница 31: ...t Drive parameters for example the20 750 DNET DeviceNet network communication option module Displays a list of available methods to access the host drive parameters DIAGNOSTIC Displays a list of available diagnostic information items for the device MEMORY Displays a list of available memory storage items for the device PROPERTIES Displays a list of available user defined convenience functions for ...

Страница 32: ...ime in hh mm ss format from fault detection The flash mode for the Fault Display screen can be changed For details see Setting Display Flashing for Fault Indication on page 42 FaultDisplayScreenSoftKeys FaultDisplayScreenSingleFunctionKey Label Name Function ESC Escape Reverts back to the previous screen without clearing the fault CLR Clear Removes the popup Fault Display screen from the display a...

Страница 33: ...y Contrast 34 Setting the Date Time for PowerFlex 750 Series Drives 35 Creating a User Defined Drive Peripheral Name 37 Customizing the Process Screen 38 Resetting the Drive Peripherals 40 Setting Factory Defaults 40 Setting Display Flashing for Fault Indication 42 Setting Display Flashing for Alarm Indication 43 Viewing Editing Drive or Peripheral Parameters 44 Viewing Clearing Drive Faults or Al...

Страница 34: ... Use the or key to select Adjust Contrast 6 Press the Enter key to display the Set LCD Contrast edit popup box 7 Use the or soft key to adjust contrast to the desired setting 8 Press the ESC soft key to set the contrast and exit the screen Port Location 01 HIM cradle on thefront of the drive 02 DPI port near the bottom of the drive control pod PowerFlex 750 Series drives or at the bottom of the dr...

Страница 35: ...y the Date Time Set screen The top line shows the present date and time in this format yyyy mm dd hh mm ss Note that the time is always displayed in a 24 hour format For example 6 00 pm is shown as 18 00 00 7 Press the EDIT soft key to access the Date Time Set Edit Mode screen which highlights the present time zone line 8 To select the time zone a Press the ZONES soft key to display the Select Tim...

Страница 36: ... enter the correct day 10 To set the time a Press the soft key to select the hour in the top line b Use the numeric keys to enter the correct hour c Press the soft key to select the minutes in the top line d Use the numeric keys to enter the correct minute e Press the soft key to select the seconds in the top line f Use the numeric keys to enter the correct seconds 11 Press the ESC soft key to ret...

Страница 37: ...appropriate soft keys to help create the new name 7 With the desired character selected in that character position press the key to select and enter the character 8 Repeat steps 4 through 7 for each character position 9 When the desired name is displayed on the edit popup box press the ENTER soft key to enter and save the new name IMPORTANT Text editing is not supported when using Asian language c...

Страница 38: ...croll to the hidden line items on the multi line view screen 3 To change the multi line view Process screen to show each of the drive monitoring items in a larger single line view press the VIEW soft key 4 Use the or key to scroll to each single line view Process screen Figure 8 Single Line View Process Screen Examples 5 To return to the multi line view Process screen press the VIEW soft key again...

Страница 39: ...In this case the Process Display 1 Edit screen is shown 3 Use the soft key to select what you want to change parameter scale or text for the drive monitoring item 4 Press the EDIT soft key to display its respective edit popup box see examples below 5 For parameter or scale editing use the numeric keys and available soft keys and press the ENTER soft key to enter and save the item For text editing ...

Страница 40: ...e device or press the ESC soft key to cancel Setting Factory Defaults The procedure to set a PowerFlex 750 Series drive and its connected peripherals to factory defaults is slightly different than the procedure used for a PowerFlex 7 Class drive and its peripherals See the respective subsection for instructions Setting PowerFlex 750 Series Drives Peripherals to Factory Defaults 1 Access the Status...

Страница 41: ... set all device parameter values to factory defaults or press the ESC soft key to cancel TIP For a description of a selected menu item press the INFO softkey Figure 9 Host and Ports Preferred Popup Box Press the ENTER softkey to affirm and set most parameters for the host drive and port devices to factory defaults In this case see the host drive and port device documentation for the settings that ...

Страница 42: ...lash Status default selects only the Status Bar item 1 Figure 3 to flash Flash None selects no flashing for the Fault Display screen Follow these steps to change the flash mode for the Fault Display screen 1 Access HIM Parameter 04 Fault Dspy Type using either the Direct Parameter Access method page 44 or Alternate Linear List method page 45 2 Press the EDIT soft key to display the Edit Fault Dspy...

Страница 43: ...ault selects only the Status Bar item 1 Figure 3 to flash Flash None selects no flashing for alarm indication Follow these steps to change the flash mode for alarm indication 1 Access HIM Parameter 05 Alarm Dspy Type using either the Direct Parameter Access method page 44 or Alternate Linear List method page 45 2 Press the EDIT soft key to display the Edit Alarm Dspy Type popup box 3 Use the and s...

Страница 44: ...OST PARAM folder 5 Use the or key to select Linear List or File Group 6 Press the Enter key to display the last viewed or first parameter in the Linear List or the last viewed or first parameter in the first Group Direct Parameter Access Method 1 Access the Status screen see Figure 6 2 Use the or key to scroll to the Port of the device whose parameters you want to access for example Port 00 for th...

Страница 45: ...ll to the PARAMETER folder 5 Use the or key to select Linear List 6 Press the Enter key to display either the device s last viewed parameter or the first parameter in the linear list 7 Use the or key to scroll to the desired parameter 8 Press the EDIT soft key for editable parameters only to display the Edit Parameter popup box Figure 11 9 Use the numeric keys decimal soft key and soft key to edit...

Страница 46: ...8 To clear faults alarms press the CLR soft key In the Select Action popup box select the appropriate action using the or key and press the Enter key to clear the active fault alarm or clear the fault alarm queue To cancel the popup box press the ESC soft key or select Cancel from the list and press the Enter key Soft Key Function ENTER Displays the Time Stamp popup box for the fault alarm Note th...

Страница 47: ...iagnostic Items for the HIM To view the HIM Diagnostic Items use the procedure described above Table 1 20 HIM A6 and 20 HIM C6S HIM Diagnostic Items No Name Description 1 LCD Contrast The present value of the HIM LCD contrast level and ability to set the contrast level from this screen 2 Common Logic Cmd The present value of the Common Logic Command being transmitted to thedrive by the HIM 3 Prod ...

Страница 48: ...ecent The event number and name are shown at the right 7 Use the or key or the following soft keys to navigate within the event queue 8 To clear events press the CLR soft key In the Select Action popup box select the appropriate action using the or key and press the Enter key to clear the event or clear event queue To cancel the popup box press the ESC soft key or select Cancel from the list and p...

Страница 49: ...ion firmware has been updated 6 Boot Updated The HIM boot firmware has been updated 7 Watchdog Timeout A program crash has occurred 8 DPI Bus Off A DPI Bus Off fault was detected 9 DPI Ping Timeout A DPI Ping Timeout faultwas detected 10 DPI Port Invalid A DPI Port ID fault was detected 11 DPI Port Changed A DPI Port Changed fault was detected 12 DPI Host Reset The host has sent a reset message 13...

Страница 50: ...l stop and a text message will appear if any of the following conditions exist A device mismatch such as firmware revision device type or device series is detected The drive is access code protected The drive is running You then have the option to completely stop the download or continue after noting the discrepancy for the parameters that could not be downloaded These parameters can then be manua...

Страница 51: ...nt to rename for example Port 00 for the host drive 3 Press the key to display its last viewed folder 4 Use the or key to scroll to the MEMORY folder 5 Use the or key to select HIM CopyCat TIP Before any CopyCat filesare created only the CopyCat From Device to HIM menu item is shown When Port 00 for the Host Drive is selected in Step 2 the Upload All Ports menu item also appears TIP When aCopyCatf...

Страница 52: ...e new name 14 With the desired character selected in that character position press the key to select and enter the character 15 Repeat steps 11 through 14 for each character position 16 When the desired name is displayed on the edit popup box press the ENTER soft key to enter and save the new name Numeric Key Function Selects the numeric character set Selects the symbols character set Selects the ...

Страница 53: ...select Delete CopyCat File 8 Press the Enter key to display the Select File To Delete popup box 9 Use the or key to select the file or all files to delete 10 Press the Enter key to display the confirmation popup box 11 Press the ENTER soft key to affirm and delete the selected CopyCat file or press the ESC soft key to cancel Another popup box will appear to confirm that the CopyCat file was succes...

Страница 54: ...ged using one of these methods Individual Screen Entry Method where individual popup screens are used to enter the required parameter association data Direct Numeric Entry Method where the required parameter association data is entered as a number string on a single popup screen The following example illustrates how to use each method to change a parameter association Suppose you want the drive sp...

Страница 55: ...t 13 Reference 6 Press the ENTER soft key to enter the selected target parameter If the target parameter Is not a bit parameter the parameter association is now changed and the indirect selector or reference parameter screen re appears with the associated parameter information shown Is a bit parameter a list of available bit numbers is displayed Use the or key to scroll to the bit number of the ta...

Страница 56: ...string that represents the target parameter s device port number parameter number and only when the target parameter is a bit parameter its bit number The number string format is PPpppp bb where PP device port number pppp target parameter number bb bit number only used when target parameter is a bit parameter 4 Press the ENTER soft key to enter the number string and complete the parameter associat...

Страница 57: ...rameters that can be destinations All links must be established between equal data types parameter value formatted in floating point can only source data to a destination parameter value that is also a floating point Establishing a Link 1 Access a valid destination parameter to be linked for example the Accel Time 1 parameter 140 for a PowerFlex 700 drive or parameter 32 for a PowerFlex 700S drive...

Страница 58: ... Using the HIM Deleting an Established Link Follow these steps to delete an established link 1 Access the screen for the destination parameter 2 Press the LINK soft key 3 In the Link popup box enter a value of zero 4 Press the ENTER soft key to delete the established link ...

Страница 59: ...red access code value Use the soft key to delete an erroneous entry For your convenience write down your assigned access code and store it in a safe place 8 Press the ENTER soft key to enter the new access code 9 After the access code verification screen appears confirm the new access code by re entering its value Thereafter the HIM immediately logs in to the drive which is indicated by the Log Ou...

Страница 60: ...cedure Factory defaults User sets CopyCat function Follow these steps to edit access code protected parameters 1 Access the Status screen see Figure 6 2 If Port 00 host drive is not shown above the ESC soft key use the or key to scroll to Port 00 3 Press the key to display its last viewed folder 4 Use the or key to scroll to the PROPERTIES folder 5 Use the or key to select Log In 6 Press the Enter...

Страница 61: ...s code value Use the soft key to delete an erroneous entry 8 Press the ENTER soft key to enter the existing access code 9 Use the or key to select Change Password 10 Press the Enter key to display the Enter New Password popup box 11 Use the numeric keys and the soft key to enter 0 the default value to disable the access code protection feature 12 Press the ENTER soft key to enter the 0 disable def...

Страница 62: ...ce that previously occupied that port it will also be shown Use the FIX soft key displayed only if all conflict types are Changed or Requires Configuration to resolve conflicts After pressing the FIX soft key a popup box will appear asking to confirm that the new device s should be accepted Press the ENTER soft key to affirm and resolve the conflicts for all devices Thereafter the HIM will re read...

Страница 63: ...n the Device Conflicts popup box 1 Select the port preceded with an X in this example Port 05 and press the INFO soft key to show additional information about the conflict see example below 2 Press the ENTER soft key to affirm and re display the Device Conflicts popup box Press the ENTER soft key to affirm and resolve all device conflicts or press the ESC soft key to cancel Stopped 0 00 Hz AUTO De...

Страница 64: ...nguage is English Follow these steps to select another supported language 1 Access the Status screen see Figure 6 2 Press the Language soft key to display the list of available languages 3 Use the or key to select the desired language 4 Press the Enter key to enter the selected language All HIM screen text now appears in the selected language Stopped 0 00 Hz AUTO X05 Not Functioning This device mu...

Страница 65: ...direct serial connection from the drive to the computer you can use the same Allen Bradley software tools described above or you can use HyperTerminal software set to the X modem protocol To obtain a firmware or language update for the HIM go to http www ab com support abdrives webupdate This website contains all firmware update files supported language files and associated Release Notes that desc...

Страница 66: ...66 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Chapter 4 Using the HIM Notes ...

Страница 67: ... mm 4 57 in 180 0 mm 7 08 in 70 0 mm 2 75 in 93 0 mm 3 66 in 16 0 mm 0 63 in 25 0 mm 0 98 in Weight 91 g 3 2 oz 173 g 5 7 oz Temperature Operating Storage 0 50 C 32 122 F 40 85 C 40 185 F Relative Humidity 5 95 noncondensing Atmosphere Important The HIM must not be installed in an area where the ambient atmosphere containsvolatileorcorrosivegas vapors ordust IftheHIMisnotgoingtobeinstalledfor a pe...

Страница 68: ...nce NOTE This is a product of category C2 according to IEC 61800 3 In a domestic environment this product may cause radio interference in which case supplementary mitigation measures may be required Certification Specification UL c UL CE C Tick UL508C CAN CSA C22 2 No 14 M91 EN50178 and EN61800 3 EN61800 3 ...

Страница 69: ... Status Scrn Value 0 Status Scrn 1 Process Scrn Type Read Write Reset Required Yes 04 Fault Dspy Type Selects the type of display flash to be shown when a drive or peripheral fault is detected Default 1 Flash Status Values 0 Flash Bklite 1 Flash Status 2 Flash None Type Read Write Reset Required No 05 Alarm Dspy Type Selects the type of display flash to be shown when a drive alarm is detected Defa...

Страница 70: ...70 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Appendix B HIM Parameters Notes ...

Страница 71: ...date guidelines 65 H HIM Human Interface Module adjusting display contrast 34 changing PowerFlex 750 Series drive parameter associations 54 checking drive peripheral firmware revisions 49 compatible products 12 CopyCat function 50 creating user defined drive peripheral name 37 customizing the Process screen 38 diagnostic items 47 events 49 features 11 firmware or language updating 65 installing 20...

Страница 72: ...on 10 removing the HIM 21 resetting the drive peripherals 40 restoring the drive peripherals to factory defaults 40 S safety precautions 12 screens main descriptions 28 selecting a language 64 setting display flashing for alarm indication 43 display flashing for fault indication 42 factory defaults 40 password 59 specifications 67 T technical support 9 time date setting for PowerFlex 750 Series dr...

Страница 73: ......

Страница 74: ...the code to route your call directly to a technical support engineer http www rockwellautomation com global support direct dial page Literature Library Installation Instructions Manuals Brochures and Technical Data http www rockwellautomation com global literature library overview page Product Compatibility and Download Center PCDC Gethelp determining how products interact check features and capab...