42
Rockwell Automation Publication 20HIM-UM001E-EN-P - May 2017
Chapter 4
Using the HIM
Setting Display Flashing for
Fault Indication
Whenever a fault for the host drive or any of its connected peripherals is
detected, a popup Fault Display screen (see
) appears. By default, only the
Status Bar flashes to alert the operator. However, you can change the flash mode
for the Fault Display screen to one of the following modes:
•
Flash Bklite; selects the entire LCD screen to flash.
•
Flash Status (default); selects only the Status Bar (item 1,
) to flash.
•
Flash None; selects no flashing for the Fault Display screen.
Follow these steps to change the flash mode for the Fault Display screen.
1.
Access HIM
Parameter 04 - [Fault Dspy Type]
using either the Direct
Parameter Access method (
) or Alternate Linear List method
(
2.
Press the EDIT
soft key
to display the Edit Fault Dspy Type popup box.
3.
Use the
and
soft keys
to select the desired flash mode. To delete an
erroneous entry, use the
soft key
.
4.
Press the ENTER
soft key
to enter your selection and return to the
parameter screen.
ESC
ENTER
Stopped
0.00 Hz
AUTO
F
?
?
Edit Fault Dspy Type
Flash Bklite
0
0 << 2
Содержание PowerFlex 20-HIM-A6
Страница 4: ...4 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Summary of Changes Notes ...
Страница 8: ...8 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Table of Contents Notes ...
Страница 22: ...22 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Chapter 2 Installing the HIM Notes ...
Страница 66: ...66 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Chapter 4 Using the HIM Notes ...
Страница 70: ...70 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Appendix B HIM Parameters Notes ...
Страница 73: ......