Rockwell Automation Publication 2711P-AP006C-EN-P - November 2018
Chapter 4
Review the Application Conversion Log
Table 7 - Conversion Log Messages: Screens and Objects
Message
Description
Message display object is converted to Multistate
Indicator object at <location>.
A message display in PanelBuilder32 software is the
same as a multistate indicator in FactoryTalk View ME
software.
Verify password button at <location> not supported.
The Verify Password button is not supported in
FactoryTalk View ME software.
Select Operator button at <location> not supported.
The Select Operator button is not supported in
FactoryTalk View ME software.
Screen security settings not converted.
Security settings are not converted in FactoryTalk View
ME software. You must reconfigure all security settings.
String popup is invoked with blank scratchpad on
<location>.
Verify operation in FactoryTalk View ME software.
Cannot find block write start tag for pilot list selector at
<location>. The visible state connection is unassigned.
The Piloted Control List Selector in PanelBuilder32
software does not have a block write tag assigned.
Assign a block write tag in FactoryTalk View ME software
if you want a visible state connection.
For LSB support, refer to online help for correct syntax of
Multistate Indicator’s Value control at <location>.
FactoryTalk View ME software does support Least
Significant Bit (LSB) on multistate and list indicators.
Check the object and make sure that the syntax is correct
for the value.
The L parameter is used only for message addresses that
are more than one word in length. See the FactoryTalk
View online help for information on the L parameter.
Blinking color images are not supported.
FactoryTalk View ME software does not support blinking
color images.
Print Only objects not supported.
FactoryTalk View ME software does not support Print
Only objects.
Line at <location> could not have property set: Width.
In FactoryTalk View ME software, lines have a line width
that is separate from the object location.
Line at <location> could not have property set: Height.
In FactoryTalk View ME software, lines have a line height
that is separate from the object location.
Numeric entry enable button at <location> could not
have property set: Minimum Value.
Numeric entry enable button at <location> could not
have property set: Maximum Value.
The Numeric Entry Enable button is converted to a
Numeric Input Enable button in FactoryTalk View ME
software.
• In PanelBuilder32 software, the input and display
floating point tags shared name and address. The
min/max values were out of range and could not be
set in the FactoryTalk View ME object.
• In FactoryTalk View ME software, set the default min
and max for floating point. The display value is an
embedded variable on the
Label tab.
Содержание PanelView Plus 7
Страница 1: ...Migrating PanelView Standard Applications to PanelView Plus 7 Migration Guide OriginalInstructions...
Страница 8: ...8 Rockwell Automation Publication2711P AP006C EN P November 2018 Table of Contents Notes...
Страница 64: ...64 Rockwell Automation Publication2711P AP006C EN P November 2018 Chapter 5 Review Object Mapping Notes...
Страница 118: ...118 Rockwell Automation Publication2711P AP006C EN P November 2018 Chapter 9 Optimize Runtime Performance Notes...
Страница 133: ......