60
Rockwell Automation Publication MPAI-IN001F-EN-P - January 2016
MP-Series Heavy-duty Electric Cylinders
Wiring Example of MP-Series Electric Cylinders to Ultra3000 Drives
Grounding Techniques for Feedback Cable Shield
1
2
3
4
5
10
14
6
7
11
D
C
B
A
BR+
BR-
F
G
W
V
U
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
SIN+
SIN-
COS+
COS-
DATA+
DATA-
+5V DC
ECOM
Green
WHT/Green
Gray
WHT/Gray
Black
WHT/Black
Red
WHT/Red
3
4
5
6
1
2
9
10
14
12
+9V DC
TS+
Orange
WHT/Orange
11
13
Green/Yellow
Blue
Black
Brown
Black
White
GND
Shield
W
V
U
TS-
COM
Blue
BRK -
BRK+
43
44
+24V
COM
2090-CPxM7DF-16AAxx, or
2090-CPxM7DF-16AFxx
Power Cable
Motor Brake
Motor Power
Connector
MP-Series
Electric Cylinder
Motor Feedback
(CN2) Connector
Three-phase
Motor Power
Thermostat
User Supplied
24V DC
2090-UXBB-DM15 Drive
Mounted
Connector
Ultra3000 Drives
2090-CFBM7DF-CDAFxx, or
2090-CFBM7DF-CEAAxx
Feedback Cable
Control Interface
(CN1) Connector
Cable Shield
Ground Clamp
Motor
Feedback
Clamp
Expose shield secured under clamp.
Clamp Screw (2)
Turn clamp over to hold small cable
secure.
Cable Tie
Exposed shield secured under
clamp.
Use 2090-K2CK-D15M connector
with these drives:
Kinetix 300
Kinetix 2000
Use 2090-K6CK-D15M connector
with these drives:
Kinetix 6000
Kinetix 6200
Kinetix 6500
Use 2090-UXBB-DM15 connector
with Ultra3000 drives.