14
Rockwell Automation Publication MPAI-IN001F-EN-P - January 2016
MP-Series Heavy-duty Electric Cylinders
•
Hand tighten the collar of a SpeedTec (M7) connector one-quarter turn.
3.
Form a drip loop in the cable to keep liquids away from the connectors.
4.
Verify the continuity and functionality of the thermal switch signals, TS+ and TS-.
These signals are transmitted through the feedback cable that connects the motor to its
controlling drive.
ATTENTION:
Make sure cables are installed and restrained to prevent uneven tension or
flexing at the cable connectors. Excessive and uneven lateral force at the cable
connectors can result in the connector’s environmental seal opening and closing as the
cable flexes.
Failure to observe these safety precautions could result in damage to the electric cylinder
motor and its components.
Flat Surface
with Logo on Top
Top of connector is relative to motor
orientation.
Feedback Connector
Drip Loop
Power Connector
Flat Surface
with Logo on Top