Allen-Bradley Kinetix 5700 Series Скачать руководство пользователя страница 17

Rockwell Automation Publication 2198-IN014A-EN-P - August 2018

17

Kinetix 5700 Regenerative Bus Supply

Input P

ow

er 

UL/CSA C

irc

uit-pr

ot

ec

tion 

Sp

ecific

at

ions

Input P

ow

er 

IEC (non-UL/CS

A) C

ir

cuit-prot

ec

tion 

Sp

ecific

at

io

ns

Kine

tix

 5

700 R

ege

nera

ti

ve

 Bus S

u

pply

U

L/CS

A A

ppli

ca

ti

ons 

(2

)

(2

)

Fo

r appli

ca

tio

ns r

eq

uiri

ng CSA

 c

er

tif

ic

at

io

n,

 fu

se

s (

Bussman

n cat

alog

 n

umber 170M

1760)

 must

 b

e add

ed t

o the DC link bet

w

een 

the 

tw

o dri

ve cl

ust

ers 

wh

en c

irc

ui

t br

ea

ke

rs 

ar

e used

 fo

r branch

 cir

cu

it p

ro

te

cti

on.

 T

he 

DC b

us f

uses ar

e no

re

qu

ired

 when 

AC

 lin

e f

uses ar

e u

se

d f

or b

ran

ch ci

rc

ui

t p

ro

tec

tio

n.

Ca

t.

 N

o.

Input V

ol

tage 

(1

)

(three

-phase) nom

(1)

Ap

pl

ie

when 

DC

-b

us v

oltag

e r

egul

atio

n i

en

ab

le

d.

 If

 DC-

bu

s v

olt

ag

e r

egu

la

tion

 is

 n

ot en

ab

led

, then 

th

e i

np

ut v

olta

ge ra

nge

 is

 3

24…

.528V A

C.

 F

or m

or

e i

nf

ormati

on on these 

tw

mod

es of

 o

per

at

io

n,

 see the Kineti

x 5700 S

er

vo Driv

es 

Us

er M

anu

al

, pu

bli

cati

on

 

219

8-U

M

002

.

B

u

ssmann F

u

ses

Ca

t.

 N

o.

Me

rsen F

u

ses

Ca

t.

 N

o.

Minia

ture C

B

Ca

t.

 N

o.

Mot

or Prote

ction CB

,

Se

lf

 P

ro

te

ct

ed

 C

M

C

Ca

t.

 N

o.

Mold

ed Case CB

Ca

t.

 N

o.

2198

-RP

088

324…5

06V A

C rm

s

LP

J-

45SP

 (4

5A)

A

JT45

 (4

5A)

140G-

G6

C3

-C6

0

2198

-RP

200

LP

J-

125

SP (125

A)

A

JT12

5 (125

A)

140G-

J6

F3-D1

5

2198

-RP

263

LP

J-

200

SP (200

A)

A

JT20

0 (200

A)

140G-K6

F3-D3

0

2198

-RP

312

LP

J-

250

SP (250

A)

A

JT25

0 (250

A)

140G-K6

F3-D4

0

Ki

n

etix

 5700 R

eg

enera

ti

ve

 Bus S

u

p

p

ly

IE

C (non-

U

L/C

SA) 

Appli

ca

tions

Ca

t.

 N

o.

Inpu

t V

olta

ge 

(1

)

(th

ree

-p

ha

se) no

m

(1)

Ap

pl

ie

when 

DC

-b

us v

oltag

e r

egul

atio

n i

en

ab

le

d.

 If

 DC-

bu

s v

olt

ag

e r

egu

la

tion

 is

 n

ot en

ab

led

, then 

th

e i

np

ut v

olta

ge ra

nge

 is

 3

24…

.528V A

C.

 F

or m

or

e i

nf

ormati

on on these 

tw

mod

es of

 o

per

at

io

n,

 see the Kineti

x 5700 S

er

vo Driv

es 

Us

er M

anu

al

, pu

bli

cati

on

 

219

8-U

M

002

.

DIN

 g

G

 F

u

se

s

Amps

, max

Mi

nia

tur

e CB

Ca

t.

 No

.

Motor Pr

ot

ec

tion C

B

Ca

t.

 N

o.

Mold

ed Case CB

Ca

t.

 N

o.

2198

-RP

088

324

…506

V A

C rms

50

1489

-M3C600

1492

-SPM3C63

0

14

0MG-H8E-

C60

140G-

G6

C3

-C6

0

2198

-RP

200

12

5

14

0MG-

J8E-

D15

140G-

J6

F3-D

15

2198

-RP

263

20

0

140G-

K6

F3-D3

0

2198

-RP

312

25

0

140G-

K6

F3-D4

0

Содержание Kinetix 5700 Series

Страница 1: ...s User Manual publication 2198 UM002 for detailed information on wiring applying power troubleshooting and integration with ControlLogix 5580 controllers with EtherNet IP communication modules or Comp...

Страница 2: ...Wiring plug connector for shunt power RC connections installed on the module These installation instructions publication 2198 IN014 Regenerative Bus Supply Cat No Module Width mm Input Voltage 1 1 Ap...

Страница 3: ...ight specifications These lifting instructions apply to catalog numbers 2198 RP200 2198 RP263 and 2198 RP312 ReadtheLiftingPrecautions Read these precautions before attempting to lift the regenerative...

Страница 4: ...secure the appropriate hardware in the designated lift points as identified in the illustrations ATTENTION To guard against equipment damage verify that the hardware is securely connected to the corre...

Страница 5: ...rt the module to the installation location IMPORTANT When approaching the full upright vertical position the weight can shift and cause the module to swing unexpectedly Control the movement of the mod...

Страница 6: ...s User Manual publication 2198 UM002 to determine the ground jumper setting ATTENTION Risk of equipment damage exists The input power ground configuration must be accurately determined When the ground...

Страница 7: ...nd right of the module is required when mounted adjacent to noise sensitive equipment or clean wire ways The recommended minimum cabinet depth is 300 mm 11 81 in Ground Configuration 1 1 Refer to the...

Страница 8: ...generative bus supply can be mounted on the far right far left or anywhere in between However the far left position is preferred to accommodate the 24V shared bus IMPORTANT Mounttheregenerativebussupp...

Страница 9: ...Hole 345 13 58 Lower Mounting Hole 420 16 54 Lower Mounting Hole 465 18 31 Lower Mounting Hole 27 5 55 0 40 0 55 0 110 55 0 110 110 165 110 110 0 00 IMPORTANT Hole spacing is measured in millimeters a...

Страница 10: ...etix 5700 drive modules Regenerative Bus Supply Cat No A mm in B mm in C mm in D mm in E 1 mm in 1 Maximum distance between lift points 2198 RP088 165 6 50 300 11 8 358 14 1 252 9 92 198 7 80 2198 RP2...

Страница 11: ...ve Bus Supply Features and Indicators on page 12 7 4 12 5 9 8 11 6 6 13 17 16 10 14 3 15 18 19 DC DC DC 24V 24V L3 L2 L1 MOD NET 2 1 1 I O 6 5 10 OK OK EN EN 5700 DC 2 1 15 20 19 20 2198 RP088 and 219...

Страница 12: ...twork status indicator 18 24V control input power CP connector 9 LCD display 19 AC Input power IPD connector 1 1 Connector plug orientation applies to 2198 RP088 and 2198 RP200 modules 2198 RP200 conn...

Страница 13: ...n 2198 UM002 for wiring examples Control Input Power CP Connector Pinout RC Pin Description Signal 2 Active shunt connections DC 1 DC CED Pin Description Signal OK Relay driven contact that provides a...

Страница 14: ...plied 24V supply COM 3 24V current sinking fast input 2 IN2 4 I O common for customer supplied 24V supply COM 5 Chassis ground SHLD 6 24V current sinking fast input 3 IN3 7 I O common for customer sup...

Страница 15: ...7 0 0 28 0 22 0 25 1 9 2 2 DC Bus power Bus bar DC DC N A 1 1 SharedDC bus powerconnectionsarealwaysmadefromdrivetodriveoverthebus barconnectionsystem Theseterminalsdonot receivediscrete wires N A 1 N...

Страница 16: ...dle high current inrush as well as fuses Make sure that the selected components are properly coordinated and meet acceptable codes which includes requirements for branch circuit protection Evaluation...

Страница 17: ...rives User Manual publication 2198 UM002 Bussmann Fuses Cat No Mersen Fuses Cat No Miniature CB Cat No Motor Protection CB Self Protected CMC Cat No Molded Case CB Cat No 2198 RP088 324 506V AC rms LP...

Страница 18: ...t protection must be provided in accordance with the National Electric Code NEC and any additional local codes Leakage current Kinetix 5700 drives produce leakage current in the protective earthing co...

Страница 19: ...IP networking and component servo drive families Kinetix Motion Accessories Specifications Technical Data publication KNX TD004 Provides product specifications for Bulletin 2090 motor and interface ca...

Страница 20: ...elp us serve your documentation needs better If you have any suggestions on how to improve this document complete the HowAre We Doing form at http literature rockwellautomation com idc groups literatu...

Отзывы: