Catalog Number Explanation
a
Nom Phase Current (A) / Nom DI7-28 Activation Voltage
3
1 A/5 A / 24V
6
1 A/5 A / 110V
7
1 A/5 A / 220V
b
Nom Earth-fault Current I/O1 and I/O2 [A]
C
1 A and 5 A
D
0.2 A and 1 A
c
Additional I/O (X8 Terminal)
6
None
7
Eight standard inputs, four TCS Hybrid inputs/outputs
8
Ten outputs
9
Eight standard inputs and four outputs
(1)
(1) Some options not UL Listed. Check with your Rockwell Automation® representative.
d
Supply Voltage [V]
A
40…265Vac/dc
B
18…36 Vdc
C
40…265Vac/dc + Arc Protection Option
D
18…36 Vdc + Arc Protection Option
E
40…265Vac/dc + DI19, DI20 + arc channel, Optional
F
18…36 Vdc + DI19, DI20 + arc channel, Optional
e
Optional Hardware (Communication port 1)
Code
Description
A
TTL/RS-232 (VCM TTL)
B
Plastic/Plastic serial fiber interface (VCM FIBRE PP)
C
N/A
D
RS-485 interface (4-wire, VCM 485-4)
E
Glass/Glass dual serial fiber interface for 857-RAD (857-VCMFIBRE
GG)
(1)
(1) Required for connection to 857-RAD Enhanced RTD Scanner. Only available in this location.
F
Rx Plastic/Tx Glass serial fiber interface (VCM FIBRE PG)
G
Rx Glass/Tx Plastic serial fiber interface (VCM FIBRE GP)
I
RJ45 connection (RS-232, VCM 232)
M
ST 100-Mbps Ethernet dual fiber interface inc. IEC 61850
N
RTD glass fiber interface for 857-RAA (857-VCMRTD)
(2)
(2) Required for connection to the 857-RAA scanner only.
f
Optional Hardware (Communication port 2)
A
None
C
RJ45 connection (RS-232, 857-VCM232)
D
RS-485 interface (2-wire, 857-VCM485-2)
L
Built-in RJ45 10 Mbps Ethernet interface
(1)
M
Built-in RJ45 10 Mbps Ethernet interface inc. IEC 61850
(1)
(1) Cannot order in combination with the following optional Communication PORT 1:
(M) ST 100-Mbps Ethernet fiber interface with IEC 61850.
N
RTD interface for 857-RAA (Glass fiber, 857-VCMRTD)
(2)
(2) Required for connection to the 857-RAA scanner only.
g
Ingress Protection Rating
-
IP30 (Standard)
I
IP54 (Optional)
C
Ip30 (standard case) with conformal coated boards
K
IP54 (dust-tight case) with conformal coated boards
Position
1
2
3
4
5
6
7
857 –
3
C
6
A
A
A
–__
a
b
c
d
e
f
g
Содержание A Series
Страница 4: ...4 Rockwell Automation Publication 857 QS001B EN P April 2017 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 857 QS001B EN P April 2017 Chapter 1 Overview Notes ...
Страница 28: ...28 Rockwell Automation Publication 857 QS001B EN P April 2017 Chapter 3 Local Panel User Interface Notes ...
Страница 37: ......