Содержание 6181X-12TPXPDC

Страница 1: ... User Interface CD Pack 8 Parts List 8 Required Tools 8 Installation Guidelines 9 Mounting Clearances 10 Product Dimensions 11 Install the Computer 12 Mount the Non display Computer on a Wall 12 Mount the Display Computer in a Panel 13 Hardware Features 15 Connect Peripherals 16 Control Drawing Class I Division 2 and Zone 2 Required Circuit Parameters for USB Peripheral Devices 17 Apply Power 18 C...

Страница 2: ...ny particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Autom...

Страница 3: ... any point and shall not directly connect to cables outside the building Cable Type Required Attribute LAN Shielded or Unshielded USB Shielded Serial RS 232 Shielded DVI Shielded VGA Shielded DC Power Unshielded Cat No Region Class Division Zone Rating Temperature 6181X NPXPDC Non display United States Class I Division 2 Groups A B C D T4 20 C Ta 70 C 1 4 F Ta 158 F Class I Zone 2 IIC T4 Canada Cl...

Страница 4: ...thority having jurisdiction Refer to control drawing information in this document for allowable circuit parameters in Class I Division 2 applications In Canada all wiring must be in accordance with Section 18 1J2 of the Canadian Electrical Code and in accordance with the authority having jurisdiction For European Zone 2 applications transient limiting shall be provided in the application that limi...

Страница 5: ...e present and appropriately designed to prevent personal injury resulting from accessibility to live parts The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to be complied with certain product safety certifications All 6181X 12 display unit...

Страница 6: ...teur dans des environnements atmosphériques explosifs par ex du gaz dont la température d inflammabilité est inférieure à 135 C ATTENTION Danger d explosion La substitution de composants peut rendre cet équipement impropre à une utilisation en environnement dangereux Ne pas déconnecter l équipement sans s être assuré que l alimentation est coupée et que l environnement est classé non dangereux Ne ...

Страница 7: ... a recovery image Refer to the Cloning Utility technical data publication 6000 TD002 for instructions Computers with solid state drives have been customized to accommodate the unique properties of the solid state drive No paging file System restore is disabled MUI languages are not pre installed Computers with solid state drives do not contain a recovery partition If additional drive space is requ...

Страница 8: ...port The instructions for installing MUI languages on your computer are supplied with the MUI CD Pack Parts List Your computer is shipped with these items Mounting hardware Panel cutout template display computer only Installation instructions Production test report System CDs Accessory CD with Cloning Utility red System Support CD with Diagnostic Utility green Microsoft Multilingual User Interface...

Страница 9: ...es build up readily Proper grounding of the equipment helps to reduce static discharges which may cause shocks and damage electronic components The enclosure or cover must remain in place at all times during operation The cover provides protection against high voltages inside the product and inhibits radio frequency emissions that might interfere with other equipment The product cannot be tilted f...

Страница 10: ...oval of peripheral components such as the CompactFlash card IMPORTANT Use adequate ventilation or other cooling methods to maintain the product temperature at its specified rating Because of self heating do not operate the computer in an enclosure by using the minimum clearances unless adequate ventilation or other cooling methods are used to lower the temperature within the enclosure The minimum ...

Страница 11: ...the computers are given in mm in Non display Computer Catalog Number 6181X NPXPDC Integrated Display Computer Catalog Number 6181X 12TPXPDC 353 00 13 90 1 60 0 06 335 28 13 20 190 50 7 5 251 00 9 88 11 30 0 44 83 40 3 28 238 18 9 37 57 50 2 26 320 00 12 60 115 00 4 53 115 00 4 53 349 00 13 74 14 50 0 57 75 40 2 97 101 30 3 99 279 00 10 98 251 00 9 88 ...

Страница 12: ...h grommets to the 1 and 2 screw position as illustrated below 3 Mount the computer on the wall and then attach the remaining two M4 panhead screws with grommets to the 3 and 4 screw position 4 Tighten the screws to a torque that is appropriate for the screw and wall Recommended torque in steel is 1 13 1 36 N m 10 12 lb in The illustration shows the location of the screw holes with the dimensions g...

Страница 13: ...enter components already installed in panel Supporting panels must be of specified thickness to be sure of proper sealing against water and dust and to provide proper support The mounting hardware supplied accommodates panel thickness between 14 8 GA or 1 6 4 2 mm 0 063 0 165 in Make sure the area around the panel cutout is clear Panel Cutout Dimensions The 6181X 12TPXPDC display computer must be ...

Страница 14: ...en the mounting clips to a torque of 1 4 N m 12 lb in by using the sequence in step 5 being sure not to overtighten Repeat this process at least three times until the clips are properly torqued making sure the gasket is compressed uniformly against the panel ATTENTION Tighten the mounting clips to the specified torque to provide a proper seal and prevent damage to the product Rockwell Automation a...

Страница 15: ...6181X IN001C EN P April 2011 Hardware Features The illustrations show the hardware features of the display industrial computers for hazardous locations Front and Side Views Catalog Number 6181X 12TPXPDC Item Component 1 LCD panel display model only 2 Storage drive bay 3 Rear cover ...

Страница 16: ... COM or DVI port secure the connected device with screws The USB ports are covered by a hinged door For more information about proper use of these ports refer to Hazardous Locations statements on page 4 Item Component 1 Serial COM ports 2 2 Ethernet ports RJ 45 2 3 DVI I port 4 PCI riser slot cover 5 Power switch 6 DC input terminal block 7 Functional ground screw 8 Hinged door covering the USB po...

Страница 17: ...r than or equal to Isc USB Imax peripheral Isc USB C a USB 20 µF This value is the maximum total capacitance that can be connected to each USB port The total capacitance of each USB peripheral and its cable must not exceed the indicated value The maximum total capacitance Ci peripheral and cable capacitance of each separate USB peripheral device shall be less than or equal to Ca USB Ci peripheral ...

Страница 18: ...al connected USB peripheral device C i peripheral and its associated cable C cable If cable capacitance and inductance are not known the following values may be used Ccable 197 µF m 60 pF ft Lcable 0 7 µH m 0 20 µH ft Apply Power Both the display and non display computers have a DC input terminal block for connecting to a 18 32V DC power source The DC power option supports operation from safety ex...

Страница 19: ...ure the DC power wires to the terminal block screws Tighten the terminal to a torque of 0 687 N m 6 1 lb in 4 Secure the ground wire by using a ring style connector to the functional earth terminal screw Tighten to a torque of 1 47 N m 13 lb in 5 Apply 18 32V DC power to the computer IMPORTANT When using the functional ground screw connect the product to earth ground by using a 1 5 mm2 16 AWG or l...

Страница 20: ...so could result in an electrical arc that can cause an explosion in a hazardous location IMPORTANT To prevent performance degradation of Ethernet communication do not subject the computer or cables to extreme radiation or conducted high frequency noise Proper cable routing and power conditioning is required to be sure of reliable Ethernet communication in an industrial environment Rockwell Automat...

Страница 21: ...ories at the Rockwell Automation website http www ab com industrialcomputers com ATTENTION Make sure to read and understand the entire installation or removal procedure first before you begin configuring the computer hardware Review the specifications of a new component before installing it to make sure it is compatible with the computer Record the model and serial number and any other pertinent i...

Страница 22: ...ar cover 1 Disconnect power from the computer 2 Loosen the three screws that secure the rear cover 1 3 Open the cover and detach it from the chassis 2 Follow these steps to reinstall the rear cover 1 Fasten the rear cover to the chassis 1 2 Tighten the three screws to secure the rear cover 2 6181X 12TPXPDC Display Computer 6181X 12TPXPDC Display Computer ...

Страница 23: ...us This slot is meant to be a data CF slot but is bootable Load a CF Card in the External CF Card Slot Follow these steps to load a CF card in the external CF card slot 1 Loosen the screw that secures the CF card slot cover 1 2 Open the CF card slot cover 2 If necessary remove existing card by pushing the button on the hinge side 3 Insert the CF card into the slot until it is firmly seated 3 4 Clo...

Страница 24: ...slot lever 2 3 Extend the CF card slot lever 3 then pull out the CF card tray 4 4 Remove the CF card lock screw 5 If necessary remove existing CF card by sliding it out of the slot 5 Insert the CF card into the slot until it is firmly seated 6 6 Secure the CF card with the CF card lock screw then reinstall the CF card tray into the computer 7 Tighten the CF card slot cover and lever screws IMPORTA...

Страница 25: ... 7 Secure the add in card with the screw from the slot cover 8 Connect the necessary cables to the add in card Refer to the documentation that came with the card 9 Reinstall the rear cover Refer to Rear Cover instructions on page 22 for more information IMPORTANT When used in hazardous locations the computer supports peripheral cards rated 4 W maximum and Class I Division 2 Groups A B C D T4 In Eu...

Страница 26: ...power from the computer 2 Remove the rear cover 3 If you want to install an additional module instead of replacing the default one proceed to step 8 4 Clip the cable tie of the existing memory module 1 and remove it from the memory slot 2 IMPORTANT Use only catalog number 6189X 4GDDR2 in the 6181X industrial computers for hazardous locations Other memory modules are not acceptable for use in hazar...

Страница 27: ...side an antistatic bag 8 Hold the new memory module by its edge and remove it from its protective packaging 9 Orient the module so that the notch on its bottom edge aligns with the keyed surface of the DIMM slot 1 10 Push the module at both ends to seat it fully into the slot 2 The holding clips will automatically lock into place once the module has been seated TIP If you insert a memory module bu...

Страница 28: ...the excess length of the cable tie 14 Repeat steps 4 13 for DIMM2 slot if a second memory module is installed 15 Reinstall the rear cover 16 Apply power to the computer RTC Battery This product contains a lithium battery which is not user replaceable Return the computer to Rockwell Automation for battery replacement IMPORTANT Reinstalling the cable tie is required to meet hazardous locations mecha...

Страница 29: ...it in its original packing material At the end of its life the battery contained in this product should be collected separately from any unsorted municipal waste The collection and recycling of batteries helps protect the environment and contributes to the conservation of natural resources as valuable materials are recovered ATTENTION Do not ship or transport the product when it is installed in a ...

Страница 30: ...ower consumption DC max 6181X NPXPDC non display 6181X 12TPXPDC display 18 32V DC 2 46 1 34 A 45 W 18 32V DC 3 28 1 79 A 60 W Heat dissipation 1 6181X NPXPDC non display 6181X 12TPXPDC display 1 Add in cards and peripherals are included in the heat dissipation value 45 W 154 BTU h 60 W 205 BTU h Peripheral loading USB ports max per port 500 mA Mechanical Weight approx 6181X NPXPDC non display 6181...

Страница 31: ...s ANSI ISA 12 12 01 CSA C22 2 No 213 Enclosure Type ratings per UL50 and CSA C22 2 No 94 2 07 Enclosure ingress protection Classified by UL per IEC 60529 ATEX Certified per EN60079 15 CE Marked for all applicable directives EMC 2004 108 EC LVD 2006 95 EC RoHS China RoHS Turkey RoHS European RoHS ATEX 94 9 EC C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissi...

Страница 32: ...s manual You can also contact a special Customer Support number for initial help in getting your product up and running New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Documentation Feedback ...