Figure 47 - Optics Cover Mounting Screws
5. Remove the optics cover.
6. Check whether the mirror on the motor is clean and remove any
contamination with an optic brush.
7. Take the new optics cover out of the packaging and remove the
protection for the seal.
8. Remove any remnants of packaging.
9. Place the optics cover on the safety laser scanner and place the new
mounting screws.
10. Tighten the front screws with the torque wrench.
11. Make sure that the optics cover is free of dirt and that it is not damaged.
Recommission the SafeZone Mini Device
1. Correctly remount the SafeZone Mini device (see
2. Connect the round plug connector on the end of the connection cable
for the SafeZone Mini device.
3. Perform an optics cover calibration with the aid of the SCD software.
IMPORTANT
When fitting the new cover, verify that the arrow on the top of the cover
points to the front and that the optics cover is fully in contact without a gap.
Screw
Screw
Screw
Содержание 442L-SFZNMN
Страница 1: ...SafeZone Mini Safety Laser Scanner Catalog Number 442L SFZNMN User Manual OriginalInstructions...
Страница 10: ...10 Rockwell Automation Publication 442L UM005B EN P April 2017 Preface Notes...
Страница 24: ...24 Rockwell Automation Publication 442L UM005B EN P April 2017 Chapter 2 Product Description Notes...
Страница 60: ...60 Rockwell Automation Publication 442L UM005B EN P April 2017 Chapter 4 Mounting Notes...
Страница 78: ...78 Rockwell Automation Publication 442L UM005B EN P April 2017 Chapter 9 Maintenance and Care Notes...
Страница 94: ...94 Rockwell Automation Publication 442L UM005B EN P April 2017 Chapter 11 Technical Specifications Notes...
Страница 96: ...96 Rockwell Automation Publication 442L UM005B EN P April 2017 Appendix A Ordering Information Notes...
Страница 100: ...100 Rockwell Automation Publication 442L UM005B EN P April 2017 Appendix C EU Declaration of Conformity Notes...
Страница 107: ......