Adapter Parameters
B-5
23
[DSI I/O Act]
Displays the Drives that are active in the
Multi-Drive mode.
Default:
xxx0 0000
Bit Values:
0 = Drive Active
1 = Drive Inactive
Type:
Read Only
Bit Definitions
0 = Drive 0 Active
1 = Drive 1 Active
2 = Drive 2 Active
3 = Drive 3 Active
4 = Drive 4 Active
5 = Not Used
6 = Not Used
7 = Not Used
24
25
26
27
28
[Drv 0 Addr]
[Drv 1 Addr]
[Drv 2 Addr]
[Drv 3 Addr]
[Drv 4 Addr]
Sets the corresponding node addresses of the
daisy-chained drives when the adapter Operating
Mode Switch (SW1) is set for Multi-Drive
operation.
Important:
The settings for these parameters
must match the Comm Node Addr parameter
settings in the respective drives. Each setting must
also be unique (no duplicate node address).
Default:
100
Default:
101
Default:
102
Default:
103
Default:
104
Minimum:
1
Maximum:
247
Type:
Read/Write
Reset Required:
Yes
29
[Web Enable]
Displays the setting of the Web Pages Switch
(SW2) on the adapter when the adapter was last
reset.
Default:
0 = Disabled
Values:
0 = Disabled
1 = Enabled
Type:
Read Only
30
[Web Features]
Sets the access to the Web interface and
Web-configurable features.
Default:
xxxx xx11
Bit Values:
0 = Disabled
1 = Enabled
Type:
Read/Write
Reset Required:
No
Bit Definitions
0 = E-mail Configuration
1 = Process Display Configuration
2-7 = Not used
Parameter
No. Name and Description
Details
Bit
Default
0
0
0
0
0
x x
x
0
1
2
3
4
5
7 6
Bit
Default
1
1
x
x
x
x x
x
0
1
2
3
4
5
7 6
Содержание 22-COMM-E FRN 1.xxx
Страница 1: ...EtherNet IP Adapter 22 COMM E FRN 1 xxx User Manual...
Страница 4: ...S ii Summary of Changes...
Страница 8: ...iv Table of Contents...
Страница 12: ...P 4 About This Manual Notes...
Страница 44: ...4 8 Configuring the Scanner or Bridge Notes...
Страница 60: ...6 10 Using Explicit Messaging Notes...
Страница 112: ...B 6 Adapter Parameters Notes...
Страница 148: ...C 36 EtherNet IP Objects Notes...
Страница 164: ...I 6 Index...
Страница 165: ......