Rockwell Automation Publication 1783-IN016B-EN-P - March 2019

3

Stratix 5700 Ethernet Managed Switches

Environment and Enclosure

ATTENTION: 

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in 

EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating.

This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such 
environments.

This equipment is supplied as open-type equipment for indoor use. It must be mounted within an enclosure that is suitably designed for those specific 
environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must 
have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA or be approved for the 
application if nonmetallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain more 
information regarding specific enclosure type ratings that are required to comply with certain product safety certifications.

In addition to this publication, see the following:

• Industrial Automation Wiring and Grounding Guidelines, publication 

1770-4.1

, for more installation requirements

• NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures

Class A Notice for Taiwan and other Traditional Chinese Markets

ATTENTION: 

This is a Class A Information Product. When used in a residential environment, it may cause radio frequency interference. Under such circumstances, 

the user may be requested to take appropriate countermeasures.

Prevent Electrostatic Discharge

ATTENTION: 

This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when 

you handle this equipment:

• Touch a grounded object to discharge potential static.
• Wear an approved grounding wriststrap.
• Do not touch connectors or pins on component boards.
• Do not touch circuit components inside the equipment.
• Use a static-safe workstation, if available.
• Store the equipment in appropriate static-safe packaging when not in use.

ATTENTION: 

The console ports are intended for temporary local programming purposes only and not intended for permanent connection. The console port 

cables are not to exceed 3.0 m (9.84 ft) and must not contain hubs.

ATTENTION: 

This product is grounded through the DIN rail to chassis ground. Use zinc-plated yellow-chromate steel DIN rail to assure proper grounding. The use 

of other DIN rail materials (for example, aluminum or plastic) that can corrode, oxidize, or are poor conductors, can result in improper or intermittent grounding. 
Secure DIN rail to mounting surface approximately every 200 mm (7.8 in.) and use end-anchors appropriately. Be sure to ground the DIN rail properly. Refer to 
Industrial Automation Wiring and Grounding Guidelines, Rockwell Automation publication 

1770-4.1

, for more information.

ATTENTION: 

Under certain conditions, viewing the optical port may expose the eye to hazard. When viewed under some conditions, the optical port may expose 

the eye beyond the maximum permissible exposure recommendations.

ATTENTION: 

Class 1 laser product. Laser radiation is present when the system is open and interlocks bypassed. Only trained and qualified personnel should be 

allowed to install, replace, or service this equipment.

Содержание 1783-BMS06SA

Страница 1: ...6 Site Requirements 7 Mount the Switch 7 Ground the Switch 8 Wire the DC Power Source 9 Install the Power Connectors on the Switch 10 Wire External Alarms 11 Install the Alarm Relay Connector on the S...

Страница 2: ...fettuare interventi di manutenzione su di esso leggere il presente documento ed i documenti elencati nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell...

Страница 3: ...inaresidentialenvironment itmaycauseradiofrequencyinterference Undersuchcircumstances the user may be requested to take appropriate countermeasures Prevent Electrostatic Discharge ATTENTION Thisequipm...

Страница 4: ...as defined in EN 60664 1 when applied in Zone 2 environments The enclosure must be accessible only by the use of a tool This equipment shall be used within its specified ratings defined by Rockwell Au...

Страница 5: ...ARNING RISQUE D EXPLOSION Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher l quipement Couper le courant ou s assurer que l environnement est class nondan...

Страница 6: ...T2000 ERG 2001 or equivalent 5 3 mm2 10 AWG copper ground wire such as Belden part number 9912 or equivalent Wire stripping tool For panel mounting without a DIN rail M5 or 10 24 or 10 32 bolts or scr...

Страница 7: ...theSwitch The switch ships with a spring loaded latch on the rear panel for mounting on a DIN rail To mount the switch on a DIN rail follow these steps 1 Position the rear panel of the switch directly...

Страница 8: ...ratcheting torque screwdriver with a Phillips head Store the ground screw for later use 2 Use the guidelines from the manufacturer to determine the wire length to be stripped 3 Insert the ground wire...

Страница 9: ...0 5 mm 0 02 in Do not strip more than 6 8 mm 0 27 in of insulation from the wire Stripping more than the recommended amount of wire can leave wire exposed after installation 5 Loosen the two captive s...

Страница 10: ...and an optional secondary power source InstallthePowerConnectorsontheSwitch To install the switch power connectors to the front panel of the switch follow these steps 1 Insert one power connector into...

Страница 11: ...ction are required to complete one input alarm circuit You must provide either an NO or an NC dry contact to complete the alarm circuit between reference ground and IN1 or IN2 The three remaining conn...

Страница 12: ...or the external alarm device into the connections that are based on an alarm input or output circuit setup See Table on page 11 5 Use a ratcheting torque flathead screwdriver to torque the captive scr...

Страница 13: ...wire Stripping more than the recommended amount of wire can leave wire exposed after installation 3 Locate the power connector 4 Insert the exposed part of the positive wire into the DC connection an...

Страница 14: ...s Once you install SFP modules in the switch be aware that the overall temperature rating of the combined modules switch and SFP modules is limited to the lowest maximum temperature rating and the hig...

Страница 15: ...e it from the module slot f Place the removed SFP module in an antistatic bag or other protective environment InstallorRemovetheSDCard To install or replace the optional SD card follow these steps 1 O...

Страница 16: ...Connectto10BASE T 100BASE TX or1000BASE TPorts To connect to 10BASE T 100BASE TX or 1000BASE T ports follow these steps 1 Choose one of these options to connect a device When connecting to workstatio...

Страница 17: ...le port and fiber optic cable and store them for future use 2 Insert one end of the fiber optic cable into the SFP module port 3 Insert the other cable end into a fiber optic receptacle on a target de...

Страница 18: ...ected by such things as the following Spanning Tree Learning mode Number of files or images in onboard memory To test the switch follow these steps 1 Apply power to the switch If the switch is directl...

Страница 19: ...rm relay 30V DC 1 0 A or 48V DC 0 5 A Isolation voltage 60V continuous basic insulation type DC power ports to ground and PoE power ports to ground No isolation between individual Ethernet ports No is...

Страница 20: ...rockwellautomation com idc groups literature documents du ra du002_ en e pdf Technical Support Center Knowledgebase Articles How toVideos FAQs Chat User Forums and Product Notification Updates https r...

Отзывы: