Data Highway Message Set
Chapter 8
835
Physical Read
Use this command only as one step in an upload procedure described in
“PLC-3 Upload/Download Procedures.” Use the value in the address
field (P ADDR) to specify the physical address of the start of the block of
data to be read from the memory at the destination for this message
packet. Use the SIZE-field value to specify the number of bytes to read.
Command Format:
SuccessReply Format:
TNS
2 Bytes
CMD
0F
USER
NODE
LINK
STS
00
TNS
2 Bytes
CMD
4F
USER
NODE
LINK
STS
00
P ADDR
4 Bytes
SIZE
DATA
244 Bytes Max.
FNC
09
Unless otherwise stated, values shown are in hexadecimal, and each block
shown represents one byte.
Restart
Use this command only to terminate an upload or download in the
procedures described in “PLC-3 Upload/Download Procedures.” At the
conclusion of an upload, this command restores the destination station to
the state it was in immediately preceding the upload procedure. At the
conclusion of a download, this command relinquishes the download
privilege and leaves the PLC-3 controller in the program-load mode.
Command Format:
SuccessReply Format:
TNS
2 Bytes
CMD
0F
USER
NODE
LINK
STS
00
FNC
0A
TNS
2 Bytes
CMD
4F
USER
NODE
LINK
STS
00