A–2
Output Voltage (V)
Adjustable from 0V to input voltage
Output Frequency (Hz)
0 to 240 Hertz Programmable
Efficiency (%)
97.5% (Typical)
Transient Protection
Standard 2 kV (Optional 6 kV using MOV module). See accessories on page A-5.
Enclosure
IP 20
Ambient Temperature
0
_
C to 50
_
C
Storage Temperature
Ć40
_
C to 85
_
C
Relative Humidity
0 to 95% (non condensing)
Vibration
1.0 G Operational - 2.5 G Non-operational
Shock
15 G Operational - 30 G Non-operational
Altitude
1,000 m (3,300 ft.) without derating
Control Input Type
For dry contact closure input - the controller has an internal 12V power supply that provides
10-mA (typical) current flow.
Also accepts open collector/solid state inputs (sinking) with maximum leakage current of 50
m
A
Start, Stop, Forward/Reverse
Configurable inputs for 2 or 3 wire control
SW1, SW2, SW3
Configurable Inputs for control of 8 preset speeds and 2 Accel/Decel times
Programmable Input
TB3-8 can be configured to select:
Accel/Decel Times
Controller Enable/Disable
Local/Remote
Approvals
ÎÎ
ÎÎ
ÎÎ
UL508C
CSA 22.2
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
Designed to meet these standards
IEC 146-1-1
FCC Class A
À
and B
À
VDE 0871
À
and 0875
À
External Speed Potentiometer
1K to 10K Ohms, 2 Watts Minimum
Analog Input (4 to 20mA)
Input lmpedance 250 Ohms
Analog Input (-10 to +10 V DC)
Input Impedance 100 K Ohms
Programmable Output
(Form C Relay contact)
Resistive rating: 0.4A @125V AC, 0.2A @ 230 V AC, 2A @ 30V DC
Inductive rating: 0.2A @ 125V AC, 0.1A @ 230V AC, 1A @30V DC
À
With external components.
Содержание 160 SSC
Страница 9: ...ii This Page Intentionally Blank...
Страница 11: ...ii This Page Intentionally Blank...
Страница 23: ...2 10...
Страница 33: ...5 6 Program Group P Parameter Description 41 0 4 2 42 43 2 1 44 1 1 3 3 45 0 1 3 3 2 0 1...
Страница 41: ...6 2...
Страница 54: ...Index I 1 4 1 4 1 1 0 3 1 3 3 1 1 1 1 0 0 3 3 3 0 4 3 1 3 1 2 3 1 3 1 3 0...
Страница 55: ...Index I 2 0 0 0 0 0 0 0 0 0...
Страница 57: ......
Страница 58: ......