Servicing Precautions
Service personnel:
Service work should be carried out by technically qualified service personnel only. Mains power is
dangerous and can kill. Do not attempt to work on a linear or switched mode power supply if you are not suitably
qualified to do so. Do not attempt to repair surface mount circuit assemblies unless you are suitably qualified and have
the necessary facilities to do so. Replacement circuit assemblies can be ordered.
Service facilities:
Ensure a suitably sized work surface is available. Ensure this is clear of dirt, debris and obstructions
which may damage the equipment surfaces. Ensure adequate lighting. Use the correct tools for the job and ensure they
are in good working order. Ensure all workshop safety requirements are adhered to.
Service information:
Check that you have all the information you need before starting the service job. Refer to the
Allen & Heath web site or contact Allen & Heath technical support for details on the latest information. Full technical
information can be downloaded from the web site Distributor Zone (password required).
Mains power:
Connect the equipment to mains power only of the type described in the user guide and marked on the
rear panel. The power source must provide a good ground connection. Ensure you always use an isolation transformer
when working on any mains power supply unit.
Mains cord and fuse:
Use the correct power cord as supplied with the equipment. Do not remove or tamper with the
ground connection in the power cord. Heed the Important Mains Plug Wiring Instructions printed in the user guide if it is
necessary to rewire the mains cord. Always replace the equipment mains fuse with the correct type and rating as
described in the user guide and marked on the equipment panel.
Opening the unit:
Switch off and remove the mains power cord before opening the equipment. Ensure all power
supply covers and safety shields are in place before applying power with the unit open for diagnostic fault finding.
Closing the unit:
Before finishing, check the quality and accuracy of the service work carried out. Remove any dirt or
debris as this may cause equipment failure in the future. Ensure all assemblies, harnesses and connectors are correctly
aligned and plugged in. Ensure that jumper settings and control configurations are correctly set according to the
requirements of the customer.
Testing the unit:
Before operating the equipment, read and adhere to the Important Safety Instructions printed in the
user guide. Test that the service work has been successfully carried out.
Shipping the unit:
Use adequate packing such as the original packaging or purpose designed flight case if you need to
ship the unit. To avoid injury to yourself or damage to the equipment take care when lifting, moving or carrying the
equipment.
Notes on the Xone:S2
User maintenance:
There are several user configurable jumper links inside. These are described in the user guide
together with instructions on how to change the default settings.
Technology:
The XONE:S2 uses SMT (surface mount) PCB technology. In certain cases it may be better to replace a
faulty assembly rather than try to fix it without the appropriate tools and training. The power supply is a built-in universal
mains input, switched mode circuit which should be serviced by suitably qualified personnel only.
Operation:
The XONE:S2 is a performance club mixer. To ensure optimum performance and reliability it should be
connected and operated as described in the user guide.
Fault finding:
Refer to the system block diagram and circuit drawings to follow through the signal path during fault
diagnosis. Replace suspected faulty components only with those specified by Allen & Heath. The use of lower grade
alternatives may degrade the performance. Ensure the RCA phono insert jumper links are pressed fully in if fitted.