MIDI Control Codes
1
TEMPO ADJ / DATA control
. The default
application for this control is to allow adjustment of
the MIDI clock speed set by the VCF 2 TAP
TEMPO button 3 . With the control in its mid
position the clock speed is unaffected. Rotate anti-
clockwise to reduce, or clockwise to increase the
clock speed. This allows external sequencers or
drum machines to be accurately aligned to the BPM
of pre recorded tracks.
An internal jumper can be reassigned to change the
function of this control to a dedicated DATA send,
and will output Control Change
CC94. See Service
Options for details.
2
START / STOP button
. Sends MIDI start/stop
data to an external sequencer or MIDI device. The
Lights yellow when pressed. Push once to transmit
MIDI start data, push again to transmit MIDI clock
stop+rewind data. MIDI output:
ON
(1
st
press),
STOP/REWIND
(2
nd
press).
3
TAP TEMPO button
. The tempo of the MIDI
clock is set by tapping it in using the button. The
BPM is determined by the last two button presses.
4
FREQ
VCF sweep control
. Both controls
independently output MIDI data
0
to
127
:
VCF 1 FREQ:
Control Change
CC12
VCF 2 FREQ:
Control Change
CC13
5
CROSSFADER
. Move the crossfader to output
MIDI data
0
(farthest left) to
127
(farthest right).
XFADER:
Control Change
CC92
6
MIDI OUT socket (chassis)
. 5 pin DIN socket.
Outputs all
XONE:92
MIDI data to an external MIDI
compatible device.
XONE:92 control
Controller Code Generated
Controller Name
VCF 1 FREQ
CC12
Effect Control 1
VCF 2 FREQ
CC13
Effect control 2
Crossfader movement
CC92
Tremolo Level
Data Controller (internal option)
CC94
Celeste Level
Tap Temp LFO 2
MIDI Clocks
Start/Stop MIDI
Start/Stop-rewind
MIDI OUT
+