Replacing the mains fuse
The AC mains fuse is located on the rear of the
RPS14
unit next to the AC mains connector. In the event of a
mains surge or under-rated fuse value, the fuse will rupture. Switch off the power supply and remove the mains
lead plug from the “MAINS INPUT” socket on the rear of the unit. Check the fuse and replace if necessary. In the
event of repeated failure of the mains fuse, consult your Allen & Heath service agent.
In the unlikely event of an internal DC rail fuse failure, consult your Allen & Heath service agent or Allen & Heath
technical support.
TO AVOID THE RISK OF FIRE REPLACE FUSE WITH THE CORRECT TYPE ONLY, AS INDICATED
ON THE UNIT.
AC~ mains input voltage
Fuse type
A&H Part No.
100V – 120V ± 10%
220V – 240V ± 10%
T 10A 250V 20mm
T 8A 250V 20mm
AL3455
AL0487
Technical specification
Mains Input Voltage Range:
Internally wired for region:
100V +/- 10% 50/60Hz
120V
+/-
10%
50/60Hz
220V
+/-
10%
50/60Hz
240V
+/-
10%
50/60Hz
Note: Contact Allen & Heath if your local mains voltage is not shown above.
Power consumption (max.)
650W
Mains Fuse:
100/120V
T10A 250V 20mm
A&H Part no:
AL3455
220/240V
T8A 250V 20mm
A&H Part no:
AL0487
Internal Fuses:
PCB Ident
Fuse type
F1 (+17.5V)
T 16A 250V 20mm
A&H Part no:
AL8154
F2 (-17.5V)
T 16A 250V 20mm
A&H Part no:
AL8154
F3 (+48V)
T 1.6A 250V 20mm
A&H Part no:
AL0466
F4 (+12V)
T 6.3A 250V 20mm
A&H Part no:
AL0395
DC Outputs:
DC Voltage Rail
Output Current
+17 VOLTS
8A Max.
-17 VOLTS
8A Max.
+12 VOLTS
4A Max.
+48 VOLTS
500mA Max.
Overall Dimensions:
Front Panel:
483mm x 88mm
19 inch 2U
Chassis
443mm x 88mm
17.4 inches
Height including feet:
92mm
3.6 inches
Depth:
328mm
12.9
inches
Weight: 12kg
26.4
lbs
Cable Assemblies:
Assembly
Description
A&H Part no:
DC cable
2.9m power supply to console cable assembly
002-583
DC LINK cable
0.75m backup supply to main supply cable assembly
002-584