background image

 

RPS14

 User Guide 

Replacing the mains fuse 

The AC mains fuse is located on the rear of the 

RPS14

 unit next to the AC mains connector.  In the event of a 

mains surge or under-rated fuse value, the fuse will rupture.  Switch off the power supply and remove the mains 
lead plug from the “MAINS INPUT” socket on the rear of the unit.  Check the fuse and replace if necessary.  In the 
event of repeated failure of the mains fuse, consult your Allen & Heath service agent. 

In the unlikely event of an internal DC rail fuse failure, consult your Allen & Heath service agent or Allen & Heath 
technical support. 

  TO AVOID THE RISK OF FIRE REPLACE FUSE WITH THE CORRECT TYPE ONLY, AS INDICATED 

ON THE UNIT.

 

AC~ mains input voltage 

Fuse type 

A&H Part No. 

100V – 120V ± 10% 

220V – 240V ± 10% 

T 10A 250V 20mm 

T 8A 250V 20mm 

AL3455 

AL0487 

 

Technical specification 

Mains Input Voltage Range: 

Internally wired for region: 

 

 

 

 

100V +/- 10%     50/60Hz 

    120V 

+/- 

10% 

50/60Hz 

    220V 

+/- 

10% 

50/60Hz 

    240V 

+/- 

10% 

50/60Hz 

 

Note: Contact Allen & Heath if your local mains voltage is not shown above. 

Power consumption (max.)  

650W 

Mains Fuse: 

 

 

100/120V 

T10A 250V 20mm 

A&H Part no: 

AL3455 

 

220/240V 

T8A 250V 20mm   

A&H Part no: 

AL0487 

 

 

Internal Fuses: 

 

PCB Ident 

Fuse type 

 

F1 (+17.5V)  

T 16A 250V 20mm 

A&H Part no: 

AL8154 

F2 (-17.5V) 

T 16A 250V 20mm 

A&H Part no: 

AL8154 

F3 (+48V) 

T 1.6A 250V 20mm 

A&H Part no: 

AL0466 

F4 (+12V) 

T 6.3A 250V 20mm 

A&H Part no: 

AL0395 

DC Outputs: 

DC Voltage Rail 

Output Current 

+17 VOLTS 

8A Max. 

-17 VOLTS 

8A Max. 

+12 VOLTS 

4A Max. 

+48 VOLTS 

500mA Max. 

Overall Dimensions: 

Front Panel: 

483mm x 88mm 

19 inch 2U 

Chassis 

443mm x 88mm 

17.4 inches 

Height including feet: 

92mm 

3.6 inches 

Depth:  

328mm  

12.9 

inches 

Weight: 12kg 

26.4 

lbs 

Cable Assemblies: 

Assembly 

Description 

A&H Part no: 

DC cable 

2.9m power supply to console cable assembly

002-583 

DC LINK cable 

0.75m backup supply to main supply cable assembly 

002-584 

 

Содержание RPS14

Страница 1: ...Linear Console Power Supply USER GUIDE Publication AP5716 RPS14 ...

Страница 2: ...erformance and reliability for which this equipment has been designed and manufactured read this User Guide before operating In the event of a failure notify and return the defective unit to ALLEN HEATH or its authorised agent as soon as possible for repair under warranty subject to the following conditions Conditions Of Warranty 1 The equipment has been installed and operated in accordance with t...

Страница 3: ...he ground connection in the power cord Water and moisture To reduce the risk of fire or electric shock do not expose the power supply unit to rain or moisture or use it in damp or wet conditions Do not place containers of liquid on it which might spill into any openings Ventilation Do not obstruct the ventilation slots or position the power supply unit where the air flow required for ventilation i...

Страница 4: ...he power supply unit cosmetics avoid placing heavy objects on the unit scratching the surface with sharp objects or subjecting the power supply unit to rough handling and vibration Environment Protect from excessive dirt dust heat and vibration when operating and storing Avoid tobacco ash smoke drinks spillage and exposure to rain and moisture If the power supply unit becomes wet switch off and re...

Страница 5: ...R CABLE Part number 002 583 Connects the RPS14 to the mixing console DOCUMENTATION including Safety Sheet AP3345 this user guide AP5716 and the Registration Card AP3594 The RPS14 The slimline RPS14 power supply unit is a high performance low noise linear power supply producing DC voltages by rectifying smoothing and regulating AC voltages from the secondary windings of a mains transformer Allen He...

Страница 6: ...this reason power supply units supplied with Allen Heath ML series mixing consoles are provided with a long 2 9m output cable to enable them to be positioned away from the mixing console Backup power supply units bought separately are provided with a shorter 0 75m output cable to combine power supply units For the same reason when rack mounting it is preferable to avoid locating the unit next to s...

Страница 7: ...ltage fluctuations immediately switch off the power supply unit and disconnect from the mains supply Combining Power supply units The RPS14 has a built in combiner allowing direct connection to another power supply unit for backup It can be combined with either another RPS14 or the alternative MPS14 power supply unit Either can be used as the main or backup supply Connect the two power supply unit...

Страница 8: ...l specification Mains Input Voltage Range Internally wired for region 100V 10 50 60Hz 120V 10 50 60Hz 220V 10 50 60Hz 240V 10 50 60Hz Note Contact Allen Heath if your local mains voltage is not shown above Power consumption max 650W Mains Fuse 100 120V T10A 250V 20mm A H Part no AL3455 220 240V T8A 250V 20mm A H Part no AL0487 Internal Fuses PCB Ident Fuse type F1 17 5V T 16A 250V 20mm A H Part no...

Отзывы: