background image

 

MPS14

 User Guide 

The MPS14 

The slimline MPS14 power supply uses switch mode technology to generate the DC voltages required by the 
console. It will operate from a wide range of ac mains input voltages. Full protection and thermally controlled fan 
cooling ensures the power unit will operate consistently. The MPS14 also has a built in combiner for connection to 
a second supply for backup. 

   

 

 

Installation 

Free standing 

The MPS14 can be operated as a freestanding unit without requiring any special cooling arrangement, but should 
not be accidentally or deliberately covered in any way. Always stand the unit on a firm flat surface well away from 
any soft furnishings or carpet. 

Rack mounting 

The MPS14 is designed as a 19 inch rack mount unit and will occupy 2U (3.5 inches) of rack space. A pair of M4 
threaded holes on each side at the rear of the chassis are provided for fixing brackets for supporting the rear of 
the unit. 

An important consideration when rack-mounting the unit is the need for natural convection of airflow over the 
whole unit. 

Good ventilation below the unit, in the floor or back of the rack, will ensure a path for continuous airflow. 

Other equipment in the rack which is known not to produce a significant amount of heat should be mounted below 
the unit. Equipment which also relies on good airflow within the rack (i.e. most power amplifiers and other power 
supplies) should be given due consideration and some space should be provided between such units and 
between the MPS14 unit. Forced convection, by means of a fan-tray, may be desirable in this situation. 

Location 

As with any power supply that contains switch mode technology, it is preferable to provide a degree of physical 
isolation of the unit from other equipment, particularly that which carries low level audio signals, to avoid any 
possible interference pick-up. For this reason the unit is provided with a long (2.9m) output cable to enable it to be 
positioned away from the mixing console. For the same reason, when rack-mounting it is preferable to avoid 
locating the unit next to signal processing equipment. 

 

CONSOLE POWER SUPPLY

MPS14

PIN 1 =  + 12V @ 4A

PIN 4 =  A GND

PIN 3 =  A GND

PIN 6 =  + 48V @ 500mA

PIN 5 =  D GND

FUSE

435W MAX

100V - 230V.AC 47-63 Hz ~

ADVANCED TECHNOLOGY / HIGH POWER DELIVERY / AUTO COMBINING

+ 17V

-17V

+ 12V

+ 48V

ON

PROTECT

CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE

ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.

WITH SAME TYPE AND RATING. DISCONNECT SUPPLY BEFORE CHANGING FUSE.

DO NOT OPEN.  NO USER SERVICEABLE PARTS INSIDE.

DO NOT OBSTRUCT VENTILATION OPENINGS.

THIS APPARATUS MUST BE EARTHED BY THE POWER CORD.

COUPER L'ALIMENTATION AVANT DE CHANGER LE FUSIBLE.

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

T5A 250V

T

MAINS INPUT

A DIVISION OF HARMAN INTERNATIONAL INDUSTRIES LTD

MADE IN ENGLAND

S/No

AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

CAUTION

PIN 2 =  + 17V @ 6.5A

PIN 7 =  -17V @ 6.5A

Содержание MPS14

Страница 1: ...Rack Mount Power Supply USER GUIDE Publication AP3898 MPS14...

Страница 2: ...mance and reliability for which this equipment has been designed and manufactured read this User Guide before operating In the event of a failure notify and return the defective unit to ALLEN HEATH or...

Страница 3: ...d connection in the power cord Water and moisture To reduce the risk of fire or electric shock do not expose the power unit to rain or moisture or use it in damp or wet conditions Do not place contain...

Страница 4: ...inal in the plug which is marked with the letter L Ensure that these colour codes are followed carefully in the event of the plug being changed Precautions Damage To prevent damage to the power unit c...

Страница 5: ...duct support through our worldwide network of approved dealers and service agents You can also access our Web site on the Internet for information on our product range assistance with your technical q...

Страница 6: ...ifiers and other power supplies should be given due consideration and some space should be provided between such units and between the MPS14 unit Forced convection by means of a fan tray may be desira...

Страница 7: ...240V Before switching on the power supply check that the ac mains fuse is of the correct type and rating This is marked on the rear panel of the power unit The power supply is provided with an IEC ty...

Страница 8: ...Fan filter part No AK4070 Replacing the mains fuse The AC mains fuse is located on the rear of the MPS14 unit next to the AC mains connector In the event of a mains surge or under rated fuse value th...

Страница 9: ...TS 6 5A Max 12 VOLTS 4A Max 48 VOLTS 500mA Max DC Output Socket Pin Connections Pin No Connection 1 12 Volts 2 17 Volts 3 Chassis 4 A GND 5 D GND 6 48 Volts 7 17 Volts Overall Dimensions Front Panel 4...

Страница 10: ...10 MPS14 User Guide www allen heath com...

Отзывы: