background image

MPS14

 User Guide 

 

 

Earthing 

Finally, some consideration should be given to the earthing arrangement of the system, at the centre of which is 
the console and the MPS14. The console chassis is earthed, to the mains earth, via the power supply.  When 
rack-mounting the MPS14 care should be taken to avoid any possible “ground loops” in the system which may 
introduce audible hum or buzz to otherwise clean audio signals. Ground loops occur where signal processing 
equipment patched to the console, has its signal earth connected to the equipment chassis. A ground loop is 
formed if the chassis of the signal processing equipment and the MPS14 chassis are in electrical contact through 
the fixing rails they share in the rack.  The MPS14 has audio 0V and mains earth connected internally. If a ground 
loop is formed operation of the “ground lift” switch on the rear panel of the MPS14 may reduce any unwanted hum 
or buzz. 

 

 

 

Using the MPS14 

The MPS14 will operate from an ac mains supply voltage from 100V to 240V. Before switching on the power 
supply, check that the ac mains fuse is of the correct type and rating. This is marked on the rear panel of the 
power unit. The power supply is provided with an IEC type mains connector and a moulded mains plug. Check 
that this is suitable for connection to the wall socket outlet. 

Always switch the power supply off before connecting or disconnecting the console power cables, removing or 
installing console modules and any servicing work.  In the event of an electrical storm, or large mains voltage 
fluctuations, immediately switch off the power supply and disconnect from the mains supply. 

During normal operation some heat is generated. This is expelled via the front panel ventilation holes. 

 

 

 

Combining MPS14 Power units 

Each MPS14 power unit has a built in combiner allowing the direct connection of other  MPS14 power units for 
backup. Connect the two power units together using the MPS14 “linking” cable (A&H Part No: 002-584) by 
plugging into the DC output sockets of each power unit. 

 

 

 

 

 

 

 

 

 

 

 

Note; the “linking” cable can be connected to either of the two MPS14 DC output connectors on both units. 

 

MPS14

BACKUP

MPS14 

To console 

“linking” cable 

COMBINING MPS14 POWER UNITS 

Содержание MPS14

Страница 1: ...Rack Mount Power Supply USER GUIDE Publication AP3898 MPS14...

Страница 2: ...mance and reliability for which this equipment has been designed and manufactured read this User Guide before operating In the event of a failure notify and return the defective unit to ALLEN HEATH or...

Страница 3: ...d connection in the power cord Water and moisture To reduce the risk of fire or electric shock do not expose the power unit to rain or moisture or use it in damp or wet conditions Do not place contain...

Страница 4: ...inal in the plug which is marked with the letter L Ensure that these colour codes are followed carefully in the event of the plug being changed Precautions Damage To prevent damage to the power unit c...

Страница 5: ...duct support through our worldwide network of approved dealers and service agents You can also access our Web site on the Internet for information on our product range assistance with your technical q...

Страница 6: ...ifiers and other power supplies should be given due consideration and some space should be provided between such units and between the MPS14 unit Forced convection by means of a fan tray may be desira...

Страница 7: ...240V Before switching on the power supply check that the ac mains fuse is of the correct type and rating This is marked on the rear panel of the power unit The power supply is provided with an IEC ty...

Страница 8: ...Fan filter part No AK4070 Replacing the mains fuse The AC mains fuse is located on the rear of the MPS14 unit next to the AC mains connector In the event of a mains surge or under rated fuse value th...

Страница 9: ...TS 6 5A Max 12 VOLTS 4A Max 48 VOLTS 500mA Max DC Output Socket Pin Connections Pin No Connection 1 12 Volts 2 17 Volts 3 Chassis 4 A GND 5 D GND 6 48 Volts 7 17 Volts Overall Dimensions Front Panel 4...

Страница 10: ...10 MPS14 User Guide www allen heath com...

Отзывы: