background image

DR-switch

 User Guide    AP4493 

4

 

Using the Logic Outputs 

 

System Block Diagram and Specification 

 

+10V

G

20 19 18 17

G

21

22

23

24

V

+ -

G

13

+ -

14

+

-

15

+

-

16

GROUND

OUT

IN

DR-LINK

DC REFERENCE

VOLTAGE

INTERNAL POWER

9-16

1-8

9-12

5-8

1-4

+10V

2K2

CONTROL

CHAIN

OPTO-ISOLATED SWITCH INPUTS     1-24

OPTO-ISOLATED LOGIC OUTPUTS     1-16

OPEN COLLECTOR

Connectors: 

Pluggable Phoenix 10way terminal 

Switch Inputs: 

Opto-isolated via 2k2 from +10V 
Switch closure connects pin to ground (5mA) 
Switch cable resistance up to 1k ohm  

Logic Outputs: 

Opto-isolated open-collector 
Floating collector (+) and emitter (-) pins 
Internal 10V DC source (500mA total max) 
External DC source (+24V 200mA each max) 

Communication: 

DR-link serial port using RJ45 connectors 
Uses Allen & Heath DR-link protocol 
2m CAT5 STP cable supplied, maximum 300m
Requires adapter card fitted to DR SysNet port
Daisy chain up to 3 units 

Configuration: 

Configure with WinDR operating software 
Requires V2.11 or greater 
Separately configure switches and output 
Latched, press, release, time of day action 

System: 

DR128          8 switch 
DR66 

        12 switch, 4 logic 

DR-switch        adds 24 switch, 16 logic

 

Power Supply: 

Universal mains input 100-240V.AC 
Independent 10V supply for connections
500mA total available 

Dimensions: 

Rack  482.5 x 143 x 44 mm (1U) 
Desk  442.5 x 141 x 48 mm 

The output is opto-coupled to isolate the 

DR-

switch

 from the connected equipment.  It 

provides an open collector output with floating 
collector (+pin) and emitter (-pin). 

Each 10way connector provides 4 open 
collector pairs as well as an in10V DC 
supply and ground pins.  Do not use the 
chassis ground screw which is for cable 
shielding and safety earthing only. 

The output may be used in many ways to 
satisfy a wide range of interfacing applications.  
It is important that the installer has a good 
working knowledge of open collector and 
interfacing circuits.  Incorrect application may 
result in damage to these outputs. 

The in10V supply may be used as the 
power source for low current applications such 
as turning on LEDs, lamps and small relays.  
One cable can feed the common supply or 
ground to a bank of outputs. 

 Maximum current drawn from the 

+10V supply for all outputs combined must not 
exceed 500mA.  Care must be taken in 
component choice to ensure each operates 
within its specified capability. 

For higher current or voltage applications an 
external DC power supply may be used.  This 
also provides total isolation between the 

DR-

switch

 and external equipment. 

 Maximum external supply voltage 

must not 24V DC.  Maximum current 
sink through any open collector output must 
not exceed 200mA. 

A few examples are shown in the diagram 
here.  For further advice contact Allen & Heath 
technical support. 

V

+ -

G

+ - +

2

1

LED INDICATORS

+10V DC 

SUITABLE RESISTORS

+ -

3

V

+ -

G

+ - +

6

5

+ -

7

+ -

4

+ -

8

V

+ -

G

+ - +

10

9

+ -

11

+ -

12

V

+ -

G

+ - +

14

13

+ -

15

+ -

16

+10V

OPEN COLLECTOR

OPTO

INTERNAL DR-switch CIRCUIT

(1 OF 4 SHOWN)

LOW CURRENT 12V BULBS

LOW VOLTAGE RELAY

+

-

TO EQUIPMENT

SUITABLE RESISTOR

+10V DC 

+10V DC 

V

-

G

+

V

-

G

+

-

+

V

-

G

+

CURRENT SINK

+V  (+24V DC max)

GROUND

EXTERNAL POWER SUPPLY

DEVICE

200mA max

Отзывы: