  Important:  Using the Switch Inputs and Logic Outputs 

The 

DR-switch

 provides contact closure switch inputs and open-collector logic outputs.  How these are wired to 

external equipment is the responsibility of the installer.  Specification details are provided here for the 

DR-

switch

 inputs and outputs.  It is important that the installer is suitably qualified and familiar with external control 

circuits to be able to work within the capabilities of the unit.  Allen & Heath do not assume responsibility for any 
damage done to the unit due to incorrect or faulty connection to external equipment. 

 

Planning and Configuring the System 

Before starting make sure you have planned how the system is to work.  Allocate the switch inputs and logic 
outputs and keep a log of their function.  The function of each input and output is configured using the Allen & 
Heath 

WinDR

 software.  Refer to the help file within the program for instructions. 

 

Connectors and Grounding 

 

 

 

Using the Switch Inputs 

 

Pluggable Phoenix type screw terminal 
connectors are used for connecting the 
external switches and logic to the 

DR-switch

.  

Mating plugs are provided with the unit. 

Make sure the wires ends are carefully stripped 
and inserted into the terminals.  Tighten the 
screws using the correct slotted screwdriver. 

To ensure interference-free operation use 
shielded cable.  Connect the shields to the 
chassis ground screw terminals provided next 
to each connector.  Fit the screws with the 
shake proof  washers provided. 

  

For operator safety make sure that 

wall plates and other control surfaces made 
from metal are correctly bonded to ground 
(earth).

 

Strap the metal plate to the local ground at the 
wall box.  For ground isolation between the 
wall plate and equipment rack connect the 
cable shield at the 

DR-switch

 end only. 

If a local ground is not available then use the 
cable shield to connect the plate to the chassis 
of the 

DR-switch

 unit as shown.   This is not 

necessary if the wall plate is made of non-
conductive material such as plastic which 
insulates it from the operator. 

G

METAL WALLPLATE

CHASSIS EARTH

G

METAL WALLPLATE

LOCAL EARTH BOND

SWITCH

SWITCH

4

3

2

1

5

6

7

8

G

G

12 11 10 9

13

14

15

16

G

G

20 19 18 17

21

22

23

24

G

G

INPUTS

2K2

+10V

OPTO

INTERNAL DR-switch CIRCUIT

(1 OF 8 SHOWN)

The input is opto-coupled to isolate the 

DR-

switch

 from the connected equipment.  It is 

switched by linking its connector pin to the 
ground (‘G’) pin.  Use a contact closure such 
as a momentary press switch to do this. 

The input pin is fed from the in10V 
reference supply through a 2k2 ohm resistor.  
Around 5mA maximum current flows when 
connected to ground.  Combined switch and 
cable resistance should not exceed 1k ohm for 
the switch to activate. 

Each 10way connector provides 8 switch 
inputs.  Either pin 1 or pin 10 ‘G’ may be used 
as the common switch ground.  One cable can 
feed this ground to a bank of switches.  Two 
are shown in the diagram here.  Do not use the 
chassis ground screw which is for cable 
shielding and safety earthing only. 

For reliable operation we recommend the use 
of heavy duty sealed switches. 