DX32 Getting Started Guide
6
AP10242 Issue 3
2.
Installing the Expander
2.1
Free standing
The Expander can be operated as a freestanding unit for shelf or floor use. It can be operated horizontally
with the connectors facing upward or sideward. Check that its plastic feet are fitted in the intended position.
Ensure adequate air flow around the unit. It must not be covered in any way. Always
stand the unit on a firm flat surface away from any soft furnishings or carpet.
2.2
Rack mounting and flight casing
The DX32 is designed as a 19 inch rack mount unit and occupies 4U of rack space. The plastic feet may
need to be removed before rack mounting; retain them for future use.
For rental, touring and other portable use, we recommend that you use a professional grade flight case.
Use the M6 screws and washers supplied with the product to rack mount.
Ensure natural convection of airflow around the unit by allowing good ventilation
below, in front of and behind the unit. Rack equipment known to produce a
significant amount of heat should not be mounted directly below the unit. Forced
convection by means of a rack mounted fan-tray may be desirable in situations
where space is restricted and the ambient air temperature is high.
2.3
Rack ears
The rack ears can be detached for shelf or floor operation, and can be mounted facing either the front or
rear panel to suit the application. They are secured to the sides of the Expander with 3 screws each as
indicated below. Use a Pozidriv screwdriver to remove or reposition the rack ears.
Feet fitted for
floor use
Feet fitted for
shelf use
Alternative mounting
points for rack ears