Allegion 8310-877 Скачать руководство пользователя страница 7

75.5933.04 ALLEGION HMSS 20190723 

Page 7 of 12

4

PROGRAMMING THE SENSOR

ALL functions are programmable using the remote control.

Use of the remote control should be within 10 – 15 feet of the sensor.

REMOTE CONTROL SET-UP

NUMBER KEYS (0 

 9)

assign value for given 
function

INTERFACE

1: New Style

2: LO21 – Old Style

 (LO21B/K/P/S/U, 

LO-LINX, MC15, DP-HUB)

UNLOCK / INQUIRE / LOCK

To UNLOCK the sensor:

Press UNLOCK key once. Red LED flashes slowly. If 
flashing fast, see Note below.

To LOCK the sensor:

Press LOCK key twice 

OR

 press once, then enter 

a 4-digit lock code. If less than 4 digits, press 
lock again after the last digit. LED goes out when 
complete.

To INQUIRE the sensor:

Unlock sensor, press desired function key, then 
press INQUIRY key – number of green flashes 
corresponds to the value.

NOTE:

 If sensor is locked, and code is unknown, 

power sensor off and then back on. Press UNLOCK 
key within 60 seconds. Re-lock with 0000 (default 
code). Sensor will unlock with one press of UNLOCK 
key when set to 0000.

DOOR CONTROL

1: Normal (LED in normal mode)

2: Door permanently open 

(red LED on)

3: Door permanently closed 

(red LED off)

INFRARED FREQUENCY

Mode

Frequency

1

2
3
4

normal

normal
quiet
quiet

low

high
low
high

See Quiet Mode note on next page.

MODES OF OPERATION

0: Normal

1: MP Mode
2: Record Mode

Sensitivity

Hold Time

Output Config

Auto-Learn Time

Pattern Width

Pattern Depth

Immunity

Set-up

see next page for specific parameter settings

"Door Closed" and "Door Open" patterns are independently adjustable.  It is necessary to adjust the pattern 

for a closed door, and then to adjust the pattern again when the door is open.  The following functions may be 

independently adjusted for each door position:

•  Sensitivity
•  Pattern width
•  Pattern depth

The following functions apply to both "Door Closed" and "Door Open" positions:

•  Auto-Learn time
•  Immunity (“medium” and “high” affect interpretation of objects in detection field relative to background; 

Learn time is unaffected)

•  Frequency
•  Output configuration
•  Door control mode
•  Hold time
•  Interface type

Содержание 8310-877

Страница 1: ...10 Power supply 12 24 VAC VDC 10 Monitoring request input 12 30 VDC required polarity sensitive min pulse width 10 ms active low Frequency 50 60 Hz Output max voltage at contacts 60 VDC 125 VAC max c...

Страница 2: ...from midpoint of each sensor SIMULTANEOUS PAIR APPLICATIONS Sensor must be mounted at center of door opening The door control unit and the header cover profile must be correctly grounded Only trained...

Страница 3: ...esired location Drill pilot holes for mounting and wire passage Partially drill the 2 mounting screws into the pilot holes Remove the left end cap of the Spacer for wiring harness routing Slide extrus...

Страница 4: ...crews provided with the kit Slide the circuit board back into the extrusion ANGLE ADJUSTMENTS MOUNTING TO SPACER REPLACE THE CIRCUIT BOARD MECHANICAL INSTALLATION cont 3 2 2 1 1 0 Should only be used...

Страница 5: ...s set to off see below Once wired feed the free end of the cable through the wire passage hole page 3 step 8 and into the header Pull the cable completely through and route it to the location of the a...

Страница 6: ...green until set up is successful in door closed position 1 Activate the door to the fully open position LED will flash green again and the sensor will execute a door open set up 1 2 NOTES 1 If the do...

Страница 7: ...00 default code Sensor will unlock with one press of UNLOCK key when set to 0000 DOOR CONTROL 1 Normal LED in normal mode 2 Door permanently open red LED on 3 Door permanently closed red LED off INFRA...

Страница 8: ...me 0 30 seconds 1 1 minute 2 2 minutes 3 3 minutes 4 5 minutes 5 7 minutes 6 10 minutes 7 15 minutes 8 10 seonds 9 Infinity no learn Pattern Width 1 Wide closed door 2 Middle open door 3 Asymm left na...

Страница 9: ...e NOTES Pressing PB1 will toggle between parameters Pressing PB2 will toggle between range of adjustments for that particular parameter The value returns to the lowest setting when PB2 is pressed agai...

Страница 10: ...5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 1...

Страница 11: ...roper relay output configuration Ensure proper relay output setting Sensor repeatedly re Learns environment with each door position Improper data from lockout device 1 Allow door to open in automatic...

Страница 12: ...ADM certified for pedestrian doors IDA certified for doors gates and factory trained for the type of door gate system Installers and service personnel are responsible for executing a risk assessment f...

Отзывы: