Allegion 8310-877 Скачать руководство пользователя страница 1

75.5933.04 ALLEGION HMSS 20190723 

Page 1 of 12

Presence sensor w/monitoring

ENGLISH

1.  End caps
2.  Lenses
3.  Center eye shield
4.  LED

Specifications are subject to change without prior notice.

All values measured in specific conditions.

Installation height (variable):

9’ 0” maximum (recommended:  6’ 6” – 8’ 0”)

Mounting angles

HMSS only:
HMSS w/Spacer:

5°, 10° (factory default setting:  5°)
0°, 5°, 10°

Power supply:

12 – 24 VAC / VDC ±10%

Monitoring request input:

12 – 30 VDC required (polarity-sensitive)
min. pulse width:  10 ms (active low)

Frequency:

50 – 60 Hz

Output:

max. voltage at contacts:  60 VDC / 125 VAC
max. current at contacts:  1 A
max. switching power:  30 W (DC), 60 VA (AC)

Relay hold time:

0.5 – 9 seconds

Operating temperature:

-22 – 140 °F

Immunity:

Immune to electrical and radio frequency interference

Cable length:

4’

Weight:

1 lb 11 oz (765 g)

Dimensions:

12” (W) x 2” (H) x 2” (D)
(300.35 mm x 49.50 mm x 48.00 mm)

Material:

Aluminum and ABS plastic

Housing color:

Black, anodized aluminum

1

1

2

2

3

4

DESCRIPTION

TECHNICAL SPECIFICATIONS

Содержание 8310-877

Страница 1: ...10 Power supply 12 24 VAC VDC 10 Monitoring request input 12 30 VDC required polarity sensitive min pulse width 10 ms active low Frequency 50 60 Hz Output max voltage at contacts 60 VDC 125 VAC max c...

Страница 2: ...from midpoint of each sensor SIMULTANEOUS PAIR APPLICATIONS Sensor must be mounted at center of door opening The door control unit and the header cover profile must be correctly grounded Only trained...

Страница 3: ...esired location Drill pilot holes for mounting and wire passage Partially drill the 2 mounting screws into the pilot holes Remove the left end cap of the Spacer for wiring harness routing Slide extrus...

Страница 4: ...crews provided with the kit Slide the circuit board back into the extrusion ANGLE ADJUSTMENTS MOUNTING TO SPACER REPLACE THE CIRCUIT BOARD MECHANICAL INSTALLATION cont 3 2 2 1 1 0 Should only be used...

Страница 5: ...s set to off see below Once wired feed the free end of the cable through the wire passage hole page 3 step 8 and into the header Pull the cable completely through and route it to the location of the a...

Страница 6: ...green until set up is successful in door closed position 1 Activate the door to the fully open position LED will flash green again and the sensor will execute a door open set up 1 2 NOTES 1 If the do...

Страница 7: ...00 default code Sensor will unlock with one press of UNLOCK key when set to 0000 DOOR CONTROL 1 Normal LED in normal mode 2 Door permanently open red LED on 3 Door permanently closed red LED off INFRA...

Страница 8: ...me 0 30 seconds 1 1 minute 2 2 minutes 3 3 minutes 4 5 minutes 5 7 minutes 6 10 minutes 7 15 minutes 8 10 seonds 9 Infinity no learn Pattern Width 1 Wide closed door 2 Middle open door 3 Asymm left na...

Страница 9: ...e NOTES Pressing PB1 will toggle between parameters Pressing PB2 will toggle between range of adjustments for that particular parameter The value returns to the lowest setting when PB2 is pressed agai...

Страница 10: ...5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 1...

Страница 11: ...roper relay output configuration Ensure proper relay output setting Sensor repeatedly re Learns environment with each door position Improper data from lockout device 1 Allow door to open in automatic...

Страница 12: ...ADM certified for pedestrian doors IDA certified for doors gates and factory trained for the type of door gate system Installers and service personnel are responsible for executing a risk assessment f...

Отзывы: