ALLDSP SMA-6P2408
3.3. System Menu
Push the Menu button to enter the system menu. Push the Menu button again to toggle through the menu
items. The available menu items are:
3.3.1. Load Preset
Turn the rotary encoder to select the preset you wish to load. Push the rotary encoder to select it, then turn it
again to select "YES" and confirm again by pushing the rotary encoder knob. The preset is loaded and all
settings are applied immediately. All settings that were in the unit prior to loading the preset will be erased.
This action can not be undone.
The presets contain all filter, dynamics, gain settings etc; in other words, everything that makes out a
loudspeaker configuration. Presets do NOT contain the name of the unit, network configuration, automatic
standby delay, user access rights and passwords.
3.3.2. Save Preset
Turn the rotary encoder to select the location of the preset. If that location is not empty, the preset in that
location will be overwritten. This action can not be undone.
The system will ask you to give a name to the preset name. Select a character in the cursor position by
turning the rotary encoder; pushing the rotary encoder confirms the character selected and moves the cursor
to the next character to edit. Pushing the exit/ESC button erases the last confirmed character. Once the
name is set up, push the menu button again. If you want to continue storing the preset, select Yes by turning
the rotary encoder and confirm by pushing it. To cancel, push the exit button. Now your preset is saved in
the selected location.
The presets contain all filter, dynamics, gain settings etc; in other words, everything that makes out a
loudspeaker configuration. Presets do NOT contain the name of the unit, network configuration, automatic
standby delay, user access rights and passwords.
3.3.3. Access Level
The SMA-6P2408 has the option of locking away the front panel controls to avoid tampering of settings by
unauthorized persons. To lock the unit, select "Locked" by turning the rotary encoder, and push it to confirm.
The system will ask you to enter a password. Select a character in the cursor position by turning the rotary
encoder; pushing the rotary encoder confirms the character selected and moves the cursor to the next
character to edit. Pushing the exit/ESC button erases the last confirmed character. Once the password is set
up, push the menu button again and the unit will be locked.
ATTENTION: Make sure to remember the password! When the unit is locked and you forgot the password, it
is not possible to unlock it without contacting your local service representative.
To unlock the unit select "Unlocked" and enter the password. The password is automatically checked after
each entered character, and the unit will exit the system menu when the password is confirmed.
The default password is "Password".
3.3.4. Version Information
By pushing the rotary encoder, the display toggles through the version information about the unit (serial
number, firmware version), as well as some parameters like IP address, subnet mask, MAC address etc.