DC application
The DC receptacle may be used for charging 12 volt automotive-type batteries only. The
zero load voltage is 15V-30V.

NOTE

 In DC operation, turn the Smart-throttle switch to the OFF position.

1. Connect the charging cables to the DC receptacle of the generator and then to the ba-
    ttery terminals.

WARNING

To prevent the possibility of creating a spark near the battery, connect charging 
cable first to the generator, then to the battery. Disconnect cable first at the 
battery.
Before connecting charging cables to a battery that is installed in a vehicle, 
disconnect the vehicles grounded battery cable. Reconnect the vehicle's 
grounded battery cable after the charging cables are removed. This procedure 
will prevent the possibility of a short circuit and sparks if you make accidental 
contact between a battery terminal and the vehicle's frame or body.

CAUTION

Do not attempt to start an automobile engine with the generator still connected 
to the battery. The generator may be damaged.
Connect the positive battery terminal to the positive charging cord. Do not re-
verse the charging cables, or serious damage to the generator and/or battery 
may occur.

WARNING

The battery gives off explosive gases; keep spark, flames and cigarettes away. 
Provide adequate ventilation when charging.
The battery contains sulfuric acid (electrolyte). Contact with skin or eyes may 
cause severe burns. Wear protective clothing and a face shield.
-If electrolyte gets on your skin, flush with water.
-If electrolyte gets in your eyes, flush with water for at least 15 minutes and call 
a physician.
Electrolyte is poisonous.
-If swallowed, drink large quantities of water or milk and follow with milk of 
magnesia or vegetable oil and call a physician.
KEEP OUT OF REACH OF CHILDREN.

2. Start the engine

NOTE

The DC receptacle may be used while the AC power is in use.
An overloaded DC circuit will trip the DC circuit protector. If this happens, wait 
a few minutes before pushing in the circuit protector to resume operation.

ON

OFF

CHARGING CABLE
(SOLD SEPARATELY)

DC CIRCUIT PROTECTOR

Содержание AP G3102

Страница 1: ...102 2000 WATT DIGITAL GENERATOR TM Owner s Manual www allpoweramerica com Distributed by ALL POWER AMERICA 2005 ALL POWER AMERICA 16273 E Gale Ave City Of Industry California 91745 www allpoweramerica...

Страница 2: ...are not followed Indicates a possibility of personal injury or equipment damage if instructions are not followed NOTE Gives helpful information If a problem should arise or if you have any questions...

Страница 3: ...lated location Wipe up spilled gasoline at once WARNING Connections for standby power to a building s electrical system must be made by a qualified electrician and must comply with all applicable laws...

Страница 4: ...at can cause serious injury Read the labels and safety notes and precautions described in manual carefully If a label is lost or becomes unreadable contact your ALL POWER AMERICA dealer for a replacem...

Страница 5: ...r ENGINE SWITCH FUEL CAP VENT LEVER CHOKE LEVER FUEL FILLER CAP MAINTENANCE COVER CONTROL PANEL STARTER GRIP Frame serial number SPARK PLUG MAINTENANCE COVER MUFFLER Control panel E type OIL ALERT IND...

Страница 6: ...d This position is recommended to minimize the fuel consumption while in operation WARNING Smart throttle system does not operate effectively if the electrical appliance requires the momentary electri...

Страница 7: ...ill advisable to visually inspect the oil level regularly OIL FILLER HOLE WARNING Gasoline is extremely flammable and is explosive under certain conditions Refuel in a well ventilated area with the en...

Страница 8: ...uitability is as yet incomplete Before buying fuel from an unfamiliar station try to find out if the fuel contains alcohol if it does confirm the type and percentage of alcohol used If you notice any...

Страница 9: ...L CAP VENT LEVER ENGINE SWITCH 2 Turn the engine switch to the ON position ON ON OFF ON 4 Pull the starter grip until resistance is felt the pull the starter grip briskly toward the arrow as shown bel...

Страница 10: ...djusting the pilot screws If you always operate the generator at altitudes higher than 1 500 m 5 000 feet above sea level have your authorized ALL POWER AMERICA service center perform these carburetor...

Страница 11: ...he total wattage of all appliances connected must be considered Do not exceed the current limit specified for any one receptacle Do not connect the generator to a household circuit This could cause th...

Страница 12: ...erloaded in excess of 1 6KVA or if there is a short in the connected appliance the output indicator light green will go OFF the overload indicator light red will go ON and current to the connected app...

Страница 13: ...nerator still connected to the battery The generator may be damaged Connect the positive battery terminal to the positive charging cord Do not re verse the charging cables or serious damage to the gen...

Страница 14: ...in the ON position If the oil alert system shuts down the engine the oil alert indicator light red will come on when you operate the starter and the engine will not run If this occurs add engine oil O...

Страница 15: ...use of re placement parts which are not of equivalent quality may damage the generator NOTE 1 Service more frequently when used in dusty areas 2 These items should be serviced by your servicing deale...

Страница 16: ...strict air flow to the carburetor To prevent carburetor malfunc tion service the air cleaner regularly Service more frequently when operating the generator in extremely dirty areas 1 Loosen the cover...

Страница 17: ...24 0 028in Correct as necessary by carefully bend ing the side electrode 7 Install the spark plug carefully by hand to avoid cross threading 8 After a new spark plug has been seated by hand it should...

Страница 18: ...beforehand Before storing the unit for an extended period 1 Be sure the storage area is free of excessive humidity and dust 2 Drain the fuel WARNING Gasoline is extremely flammable and explosive under...

Страница 19: ...dealer Still no spark YES YES NO NO NO Be sure there is no spilled fuel around the spark plug Spilled fuel may ignite WARNING If the engine still does not start take the generator to an authorized de...

Страница 20: ...2 5000 5000 T C I A7RTC Recoil starter Automotive unleaded gasoline 630 SAE 10W30 above CC grade Fuel tank capacity L Continuous running time hr at rated output Noise level zero load full load dB A 7m...

Страница 21: ...of the control plate 2 Disperse the mount plate of the Light Use screw M5 45 and screw M5 16 then locate the mount plate of Light Kit on generator DO NOT TIGHTEN SCREWS 3 Use the antiskid round stud...

Отзывы: