10
ELECTRICAL CONNECTION
Ÿ
All gate operators
MUST
be properly grounded. This minimizes or prevents damage due to electrical charge,
such as a near lightening strike or an electrical static discharge.
Ÿ
Use a single wire for the ground.
DO NOT
splice two wires for the ground. If the wire breaks or is cut, replace it
with a single length wire.
NEVER
use two wires for the ground.
Ÿ
Check the local city code for proper earth ground rod type and grounding procedures.
OPERATORS
MUST
BE PROPERLY GROUNDED!
230V
1
15V
GRD LINE 1 LINE 2
Ÿ
Use a minimum of a
20-amp
, dedicated circuit for power.
Power Connection
115 VAC
220 VAC Single Phase
LINE 1
115V HOT
220V LINE 1
LINE 2
115V NEUTRAL
220V LINE 2
GND
GROUND
GROUND
POWER AND BATTERY
SWITCHES
NOTE:
WHEN APPLYING
230V TO THE OPERATOR,
MAKE SURE VOLTAGE
SWITCH IS FLIPPED TO 230V
POWER BOARD