background image

22

21

MONITORED ENTRAPMENT PROTECTION 

DEVICE CONNECTIONS

LOOP RACK INSTALLATION

OUTSIDE

SAFETY LOOP

INSIDE 

SAFETY LOOP

EXIT LOOP

WHEN USED

Exit Loop

Phantom Loop

Safety Loop

See side for 

Jumper setting

COMPATIBLE PLUG IN DETECTORS

Exit

Loop

Loop

Loop

Safety

Phantom

24VAC/

12VDC

Ground

Exit

Phantom

Safety

24VDC

GROUND

EXIT

PHANTOM

SAFETY

AC BOARD

LOOP RACK

EXIT LOOP

SAFETY

PHANTOM

24-COM

24-VDC

IMPORTANT:

REMOVE BLACK JUMPER FROM 

 

SAFETY

WHEN A SAFETY DEVICE IS INSTALLED

RED

BLACK

GREEN

BROWN

WHITE

WIRE COLOR

JUMPER SETTING

NOT INCLUDED ON SL-100 AC

BRAND

MODEL

JUMPER SETTING

RENO A&E
EDI
DIABLO 

H2
LMA-1800
DSP-40S

OFF
OFF
ON

  NP2-ES

NORTHSTAR

ON

DIABLO 

DSP-55

OFF

DIABLO 

DSP-50

OFF

Ÿ

The SL-100ACFP and SL-150AC models come equipped with the pre-wired LPR-1 loop rack for safety and exit 
plug in loop detectors, making installation quick and efficient.

Ÿ

Hardwired loop detectors with harnesses can also be installed. The circuit board has 24 VDC and 120 VAC 
terminals to power the detector of your choice. See “Accessory Connections” page for wiring instructions.

Ÿ

Wire one or more safety devices 

in series

 with the loop rack wires. To do this, remove the white wire 

(N.C.)

 from 

the loop rack off of the SAFETY terminal on the circuit board and wire nut to the COM of the additional device. 
Connect the N.C. contact of the additional device to the SAFETY terminal of the board.

Ÿ

Use different frequencies for each loop detector to eliminate interference. 

IMPORTANT:

 

ENFORCER E-960-D90GQ/

E-931-S33RRGQ / E-931-S50RRGQ

CONTACT

BOARD TERMINAL

 N.C.

MON_CLOSE OR

MON_OPEN

 COM

COMMON

 12-30 VDC/AC 

COMMON

12-30 VDC/AC

MON_12/24VDC

ENFORCER

E-936-S45RRGQ

WIRE

BOARD TERMINAL

BLACK

MON_CLOSE OR

MON_OPEN

WHITE

COMMON

BLUE 

COMMON

BROWN

MON_12/24VDC

ALLEN BRADLEY

GRU-24

WIRE

BOARD TERMINAL

BLACK

MON_CLOSE OR

MON_OPEN

ORANGE

COMMON

BLUE

COMMON

BROWN

MON_12/24VDC

OMRON

E3K-R10K4-NR

SWITCH

CONTACT

BOARD 

TERMINAL

LIGHT 

ON

N.O.1

MON_CLOSE OR 

MON_OPEN

COM

COMMON

24 TO 240 

VAC

COMMON

24 TO 240 

VAC

MON_12/24VDC

EMX 

IRB-RET / IRB-MON

SWITCH

CONTACT

BOARD 

TERMINAL

SW1 - 

OFF

N.C.

MON_CLOSE OR 

MON_OPEN

SW2 - 

OFF

COM

COMMON

SW3 - 

OFF

POWER/

VRX

COMMON

SW4 - 

ON

POWER/

VRX

MON_12/24VDC

EMX 

IRB-325

CONTACT

BOARD TERMINAL

N.C.

MON_CLOSE OR

MON_OPEN

COM

COMMON

POWER 

COMMON

POWER

MON_12/24VDC

EMX 

NIR-50

WIRE

BOARD TERMINAL 

BLACK

MON_CLOSE OR

MON_OPEN

WHITE

COMMON

BLUE 

COMMON

BROWN

MON_12/24VDC

TRANSMITTER SOLUTIONS

R50R-UL/R32P-UL/SR33HD/SR66HD

CONTACT

BOARD 

TERMINAL

N.C. (3)

MON_CLOSE OR

MON_OPEN

COM (5)

COMMON

NON POLARITY (1)

COMMON

12-30 VDC/AC (2)

MON_12/24VDC

MILLER EDGE RBAND

MINIMUM 6 WIRES REQUIRED

 

SWITCH

CONTACT

BOARD 

TERMINAL

SW 1 - 

ON

CS 1 
CS 2

MON_CLOSE 

MON_OPEN

SW 2 - 

OFF

CS 1
CS 2

COMMON
COMMON

SW 3 - 

ON

COM.A

TEST

COMMON

MON_12/24VDC

SW 4 - 

ON

12/24 (+)

AC/DC

24-VDC

GROUND

TRANSMITTER SOLUTIONS

iGAZE RE KIT

SWITCH

CONTACT

BOARD 

TERMINAL

ALL

OFF

N.C.1

MON_CLOSE OR 

MON_OPEN

COM

COMMON

(-) 12/24

VDC

COMMON

(+) 12/24

VDC

MON_12/24VDC

EMX 

WEL-200

CONTACT

BOARD 

TERMINAL

RELAY CLOSE (NC)

RELAY OPEN (NC)

MON_CLOSE

MON_OPEN

RELAY CLOSE (COM)

RELAY OPEN (COM)

COMMON
COMMON

POWER 

COMMON

POWER

MON_12/24VDC

MILLER EDGE

REFLECTI-GUARD/RG-K

CONTACT

BOARD 

TERMINAL

TB 2 - N.C.

MON_CLOSE OR

MON_OPEN

TB 2 - COM

COMMON

TB 1 - POWER IN (-)

COMMON

TB 1 - POWER IN (+)

MON_12/24VDC

Содержание SL-100 AC

Страница 1: ......

Страница 2: ......

Страница 3: ...tion Setting 14 Programmable Relay and Leaf Delay 15 Timer Adjustment and Radio Setting 16 Electronic Reversing Device ERD Adjustment 17 Dip Switch Functions 18 WIRING ACCESSORIES TO CIRCUIT BOARD Acc...

Страница 4: ...the gate is not moving It is advised that the power be turned off Always keep people and objects away from the gate No one should cross the path of a moving gate The gate operator must be tested month...

Страница 5: ...minimum force setting that will allow for reliable gate operation Install the operator inside the fence line Do not install the operator on the public side of the fence line Install a proper electric...

Страница 6: ...cted access locations not servicing the general public and where unauthorized access is prevented via supervision by security personnel THE SIX TYPES OF OBSTRUCTION SENSING SYSTEMS TYPE A Inherent ent...

Страница 7: ...th internal clutch Dimensions 12 W X 17 5 L X 23 5 H 15 W X 19 5 L X 25 H Shipping Weight 100 lbs 150 lbs Emergency Release SL 100 AC Push open with power off SL 100 ACFP Foot pedal release Foot pedal...

Страница 8: ...LTS 1 2 X 3 1 2 AREA FOR CONDUIT OPERATOR CONCRETE PAD OPERATOR FRAME GATE TRACK GATE TRACK FOOTING MINIMUM 5 10 17 2 CHAIN LINE 23 GATE TRACK FOOTING 8 24 4 6 5 INSTALL 4 ABOVE GROUND WHEN POSSIBLE F...

Страница 9: ...4 16 25 30 7 5 4 RED HEAD BOLTS X 3 AREA FOR CONDUIT GATE TRACK GATE TRACK FOOTING MINIMUM 5 10 15 20 1 75 CHAIN LINE 8 24 4 INSTALL 4 ABOVE GROUND WHEN POSSIBLE FOOTING FOR GATE OPERATOR TRACK FOOTIN...

Страница 10: ...Y GATE CLOSED GATE OPERATOR TRACK FOOTING OPERATOR FOOTING DRIVE CHAIN DRIVE CHAIN FRONT VIEW OVERHEAD VIEW TOP OF OPERATOR PAD TOP OF OPERATOR PAD SL 150AC TRACK FOOTING OPERATOR FOOTING GATE IN OPEN...

Страница 11: ...E OPERATOR OPERATOR FOOTING TRACK FOOTING TRACK FOOTING FRONT VIEW OVERHEAD VIEW GATE OPERATOR FOOTING MOVE ONE IDLER TO THE BOTTOM CENTER HOLE AND FOLLOW THE CHAIN PATH AS SHOWN CHAIN PATH GATE POST...

Страница 12: ...non contact photoelectric sensor or contact edge for each entrapment zone prior to gate operation The operator cycles power to the external entrapment protection device and checks for device signals I...

Страница 13: ...an All O Matic circuit board use the following SAFETY LOOP Normally Closed N C Contacts EXIT OPEN CMD Normally Open N O Contacts See page 22 for LPR 1 loop rack wiring Loop wires MUST be twisted from...

Страница 14: ...d If the wire breaks or is cut replace it with a single length wire NEVER use two wires for the ground Check the local city code for proper earth ground rod type and grounding procedures Use UL listed...

Страница 15: ...it box on SL 150 AC and follow the steps below 1 Turn the power OFF on the operator 2 Push the limit lock plate down on the SL 100 AC or outwards on the SL 150 AC 3 Turn the limit nut toward the switc...

Страница 16: ...important to not over tighten the clutch as it is a method of protecting the operator Follow these instructions to tighten the clutch when necessary To increase the torque use a pipe wrench to turn t...

Страница 17: ...operator The direction of gate opening is determined from behind the gate operator LEDs will show opening and closing direction when the gate is moving OPEN L R switch OFF is for left hand opening OPE...

Страница 18: ...in motion Typically used for an audible alarm or strobe light to warn when the gate is in motion 3 Alarm system output Activates the relay when the gate is forced open 4 ON when gate is not fully clos...

Страница 19: ...lose can be set from 1 to 60 seconds TIMER OFF Gate operation is push button to open push button to close RADIO ON To override the timer and allow the radio receiver to close the gate before the timer...

Страница 20: ...vehicle has cleared the loop the gate will stop and close If a second vehicle goes over the loop while the gate is closing the gate will stop The vehicle must get off of the loop before the gate cont...

Страница 21: ...c Reversing Device ERD which will cause the gate to reverse direction when it comes into contact with an obstruction The amount of force required to reverse the gate s direction depends on the ERD sen...

Страница 22: ...circuit board s 24 VDC terminal provides up to 700 mAmps to power accessories such as loop detectors keypads etc If the total current draw of your accessories exceeds the 700 mAmps a separate power su...

Страница 23: ...re are 2 types of sensors that can be connected to the gate operator for UL 325 monitored entrapment compliance non contact sensors photo eye and contact sensors edge sensors Monitored entrapment prot...

Страница 24: ..._OPEN COM COMMON POWER COMMON POWER MON_12 24VDC EMX NIR 50 WIRE BOARD TERMINAL BLACK MON_CLOSE OR MON_OPEN WHITE COMMON BLUE COMMON BROWN MON_12 24VDC TRANSMITTER SOLUTIONS R50R UL R32P UL SR33HD SR6...

Страница 25: ...IABLO DSP 55 OFF DIABLO DSP 50 OFF The SL 100ACFP and SL 150AC models come equipped with the pre wired LPR 1 loop rack for safety and exit plug in loop detectors making installation quick and efficien...

Страница 26: ...ted on the board to make limit and ERD adjustments easier An external three button station may also be installed See diagram below for wiring instructions NOTE On SL 100 AC model STOP CMD jumper must...

Страница 27: ...LINK LED should be ON on both machines 4 Connect all accessories to the master operator Accessories installed on the slave operator will not work Note Accessory power may be connected to the slave op...

Страница 28: ...l strip located outside of the control box For 4 wire receivers connect the 2 gray wires to terminals 1 and 2 on the receiver terminal strip located outside of the control box Connect the black wire t...

Страница 29: ...appropriate voltage specific to the lock accessory and two wires When using a magnetic lock the LOCK dip switch 4 must be turned ON The LOCK OUTPUT LED will turn on to show the lock is magnetized When...

Страница 30: ...es to manually open the SL 100 ACFP and SL 150 AC 1 Turn operator power OFF 2 Push foot pedal down and move to the left to lock pedal in down position 3 Push gate open NOTE These operators are equippe...

Страница 31: ...y of the owner These warranties are in lieu of all other warranties either expressed or implied and ALL O MATIC INC shall not be liable for consequential damage All implied warranties of merchantabili...

Страница 32: ..._ ________________________________________ ________________________________________ ________________________________________ ________________________________________ __________________________________...

Страница 33: ..._ ________________________________________ ________________________________________ ________________________________________ ________________________________________ __________________________________...

Страница 34: ..._ ________________________________________ ________________________________________ ________________________________________ ________________________________________ __________________________________...

Страница 35: ...32...

Страница 36: ...33...

Отзывы: