22
21
MONITORED ENTRAPMENT PROTECTION
DEVICE CONNECTIONS
LOOP RACK INSTALLATION
OUTSIDE
SAFETY LOOP
INSIDE
SAFETY LOOP
EXIT LOOP
WHEN USED
Exit Loop
Phantom Loop
Safety Loop
See side for
Jumper setting
COMPATIBLE PLUG IN DETECTORS
Exit
Loop
Loop
Loop
Safety
Phantom
24VAC/
12VDC
Ground
Exit
Phantom
Safety
24VDC
GROUND
EXIT
PHANTOM
SAFETY
AC BOARD
LOOP RACK
EXIT LOOP
SAFETY
PHANTOM
24-COM
24-VDC
IMPORTANT:
REMOVE BLACK JUMPER FROM
SAFETY
WHEN A SAFETY DEVICE IS INSTALLED
RED
BLACK
GREEN
BROWN
WHITE
WIRE COLOR
JUMPER SETTING
NOT INCLUDED ON SL-100 AC
BRAND
MODEL
JUMPER SETTING
RENO A&E
EDI
DIABLO
H2
LMA-1800
DSP-40S
OFF
OFF
ON
NP2-ES
NORTHSTAR
ON
DIABLO
DSP-55
OFF
DIABLO
DSP-50
OFF
Ÿ
The SL-100ACFP and SL-150AC models come equipped with the pre-wired LPR-1 loop rack for safety and exit
plug in loop detectors, making installation quick and efficient.
Ÿ
Hardwired loop detectors with harnesses can also be installed. The circuit board has 24 VDC and 120 VAC
terminals to power the detector of your choice. See “Accessory Connections” page for wiring instructions.
Ÿ
Wire one or more safety devices
in series
with the loop rack wires. To do this, remove the white wire
(N.C.)
from
the loop rack off of the SAFETY terminal on the circuit board and wire nut to the COM of the additional device.
Connect the N.C. contact of the additional device to the SAFETY terminal of the board.
Ÿ
Use different frequencies for each loop detector to eliminate interference.
IMPORTANT:
ENFORCER E-960-D90GQ/
E-931-S33RRGQ / E-931-S50RRGQ
CONTACT
BOARD TERMINAL
N.C.
MON_CLOSE OR
MON_OPEN
COM
COMMON
12-30 VDC/AC
COMMON
12-30 VDC/AC
MON_12/24VDC
ENFORCER
E-936-S45RRGQ
WIRE
BOARD TERMINAL
BLACK
MON_CLOSE OR
MON_OPEN
WHITE
COMMON
BLUE
COMMON
BROWN
MON_12/24VDC
ALLEN BRADLEY
GRU-24
WIRE
BOARD TERMINAL
BLACK
MON_CLOSE OR
MON_OPEN
ORANGE
COMMON
BLUE
COMMON
BROWN
MON_12/24VDC
OMRON
E3K-R10K4-NR
SWITCH
CONTACT
BOARD
TERMINAL
LIGHT
ON
N.O.1
MON_CLOSE OR
MON_OPEN
COM
COMMON
24 TO 240
VAC
COMMON
24 TO 240
VAC
MON_12/24VDC
EMX
IRB-RET / IRB-MON
SWITCH
CONTACT
BOARD
TERMINAL
SW1 -
OFF
N.C.
MON_CLOSE OR
MON_OPEN
SW2 -
OFF
COM
COMMON
SW3 -
OFF
POWER/
VRX
COMMON
SW4 -
ON
POWER/
VRX
MON_12/24VDC
EMX
IRB-325
CONTACT
BOARD TERMINAL
N.C.
MON_CLOSE OR
MON_OPEN
COM
COMMON
POWER
COMMON
POWER
MON_12/24VDC
EMX
NIR-50
WIRE
BOARD TERMINAL
BLACK
MON_CLOSE OR
MON_OPEN
WHITE
COMMON
BLUE
COMMON
BROWN
MON_12/24VDC
TRANSMITTER SOLUTIONS
R50R-UL/R32P-UL/SR33HD/SR66HD
CONTACT
BOARD
TERMINAL
N.C. (3)
MON_CLOSE OR
MON_OPEN
COM (5)
COMMON
NON POLARITY (1)
COMMON
12-30 VDC/AC (2)
MON_12/24VDC
MILLER EDGE RBAND
MINIMUM 6 WIRES REQUIRED
SWITCH
CONTACT
BOARD
TERMINAL
SW 1 -
ON
CS 1
CS 2
MON_CLOSE
MON_OPEN
SW 2 -
OFF
CS 1
CS 2
COMMON
COMMON
SW 3 -
ON
COM.A
TEST
COMMON
MON_12/24VDC
SW 4 -
ON
12/24 (+)
AC/DC
24-VDC
GROUND
TRANSMITTER SOLUTIONS
iGAZE RE KIT
SWITCH
CONTACT
BOARD
TERMINAL
ALL
OFF
N.C.1
MON_CLOSE OR
MON_OPEN
COM
COMMON
(-) 12/24
VDC
COMMON
(+) 12/24
VDC
MON_12/24VDC
EMX
WEL-200
CONTACT
BOARD
TERMINAL
RELAY CLOSE (NC)
RELAY OPEN (NC)
MON_CLOSE
MON_OPEN
RELAY CLOSE (COM)
RELAY OPEN (COM)
COMMON
COMMON
POWER
COMMON
POWER
MON_12/24VDC
MILLER EDGE
REFLECTI-GUARD/RG-K
CONTACT
BOARD
TERMINAL
TB 2 - N.C.
MON_CLOSE OR
MON_OPEN
TB 2 - COM
COMMON
TB 1 - POWER IN (-)
COMMON
TB 1 - POWER IN (+)
MON_12/24VDC