SAFETY INSTRUCTIONS

O  I G  ITA  L  WATE  R  IO  N  IZE  R

If  the  unit  is  immersed  in  water,  immediately  pull  out  the  power

MIEII 

plug  and  then  take  the  unit  out  of  the  water.

^
^

^

Try  to  avoid  an  electric  circuit  overload  of  an  outlet  or  electric

wiring.  Connect  the  unit  power  plug  to  an  AC  power  outlet.

>  Ensuring  that  the  unit  is connected  directly  to  a  power  supply  outlet

will  avoid  a circuit  overload  and  reduce  risk factor.

Do  not  touch  the  plug  with  wet  hands  when  you  insert  or  remove  it

from  a power  outlet.

For a stable fit,  plug  in the  power cord  completely.

 

If the  plug  fitting  is not stable,  it may emit  electric  shocks  or cause  a

fire due  to overheating.

 

Do  not use a  damaged  plug or an  unstable  power  outlet.

If 

 

the 

 

supplied 

 

cord 

 

is 

 

damaged, 

it 

 

must 

 

be 

 

replaced 

 

by 

 

the

X?Il 

         

manufacturer  or  a service  agent.  Please  contact  the  business  who

MBfiI 

        

sold  you  the  product  and  refer  to  the  manufacturer's  warranty.

Do  not  install  the  unit  in  below-freezing

fire  hazards.

 

Correct  room temperature  range:  10 ~ 35oC

Correct  inflow water  temperature:  5 

30oC

AK

temperature  or  near  any 

 

;'

@

"O 

'

Do not  install the  unit in direct  sunlight.

Extreme  environment  exposure  may  cause  the  body  of  the  exterior

unit  to  discolor  and  may  cause  the  casing  of  the  entire  unit  to

warp/twist.  This may result  in mechanical  failure.

Always  install  the  unit  on  a horizontally  flat  and  sturdy  surface.

\  a 

~j/ 

Do  not  place  heavy  items  on  the  top  of  the  unit.

/

Содержание AML 3000

Страница 1: ...Or AMS3HO AMS3 Operation Manual 000 KFDA No2670 By KFDA RoHSU 189L Q...

Страница 2: ...ANT SAFETY INSTRUCTIONS PACKAGECONTENTS APPEARANCE AND FUNCTIONS INSTALLATION OPERATION FILTERREPLACEMENT FILTER COMPOSITION pH VALUETEST TROUBLESHOOTING UNITSPECIFICATIONS WARRANTY CARD UNITCONVERSIO...

Страница 3: ...n or instruction Children must be supervised not to play with this appliance Va For Best Product Use As a precaution always discard the water that is initially dispensed This will ensure the consisten...

Страница 4: ...tric shocks or cause a fire due to overheating Do not use a damaged plug or an unstable power outlet If the supplied cord is damaged it must be replaced by the X Il manufacturer or a service agent Ple...

Страница 5: ...llow the unit to perform water input and output for 2 3 minutes s Never allow hot water input in the unit This may cause severe damage to its m filter and electrolytic chamber Never spray the unit wit...

Страница 6: ...st reagent is flammable Do not use an aluminum weak against alkaline copper weak against acid or other metallic container to store ionized water Glass or ceramic containers are recommended _ Do not dr...

Страница 7: ...TAL WATER IONIZER AML 3000 Unit Body AML 30005 Acidic Water Outlet Hose Oneouch Check Valve Fitting Safety Key Water Diveer Source Water Inlet Hose Accessories are subject to change depending on the p...

Страница 8: ...O Dill B Dill 0III m 6 Alkaline Water Outlet Dispenser AML 3000 Swing Type AML 30008 Flexible SUS Tube Type 7 Filter Connection Terminal A filter cartridge must be connected to the terminal when the...

Страница 9: ...choice of alkaline water 11 Water Inflow RateIndicator Optimum flow rate 2 0 2 5 liter minute 12 Inlet Water Temperature Indicator Optimumtemperaturerange 5 30QC 13 Filter Lifespan Icon Indicator bars...

Страница 10: ...INSTAIIATION DIGITAL WATER IONIZER Alkaline Water comes out _ Acidic Water __________ comes out AML 3000 Main body Main body Acidic Water comes out AML 30005 Alkaline Water comes out...

Страница 11: ...aution Flow Direction 3 Connect the hose to Acidic Water Outlet Port and cut the other end of the hose so that you have enough length to reach the sink This allows you to drain the acidic water or to...

Страница 12: ...at the top of the unit The dispenser should be used as follows 1 Horizontally swing the dispenser arm to the front or from side to side 2 The dispenser arm can be extended horizontally for two additi...

Страница 13: ...inflow rate is indicated in numerical value The optimum inflow rate is 2 0 2 5 liter minute Use Operation Knob to adjust the water inflow rate The screen backlight will vary according to the chosen f...

Страница 14: ...uched from Purified Water mode The unit emits an Alkaline Strength Level 1 voice guide _ Alkaline water is generated after the water flow direction alteration is finished Alkaline water is released fr...

Страница 15: ...guide and melody Acidic water is generated after the water flow direction alteration operates within 15 seconds Alkaline water is released from the lower Water Outlet Hose Acidic water is released fr...

Страница 16: ...the top of Water Outlet Dispenser NOTE No water is dispensed from Water Outlet Hose b The screen backlight color will be green to indicate purified water mode Pu water choice indication Water flow dir...

Страница 17: ...melody sound is off the voice guide will stillwork Ritefe IE __ Cpl ACIDIC c S If fjf w w Level Then 5 Flow 2 5I Fineire __ Cpl ACIDIC orlf ze S jjf j f S Level The m S Flow 2 1 Icon disappears Icon...

Страница 18: ...Power Switch Note Do not continue to use the expired fitter __________________ The icon starts flickering when 3 4 of the full filter life remains available Open FilterCover as shown below b 2 Pull F...

Страница 19: ...peat 2 or 3 times K After replacing a new filter the initial outlet water may be darkly colored This color is caused by an outflow of activated carbon fines from the new filter The carbon fines are no...

Страница 20: ...ce water quality and unit operation conditions Always use the manufacturer s authentic filters The following conditions are the results of NOT using an authentic filter The unit s self check function...

Страница 21: ...st ActivatedCarbon removes any remaining angrichemicals disinfectants phenols trihalomethane and other harmful chemicals in the source water 1 UltraHollowFiberMembraneFilter UFFilter traps and filters...

Страница 22: ...ring the mixed solution color with the provided Calorimetric Analysis Chart Obtainable pHvaluecanvaryaccordingtosourcewater quality waterinflowrateandwatertemperature DMD Calorimetric analysis chart p...

Страница 23: ...ing operation TDS TotalDissolved Solids is too high Well or underground water was used Itis the apparatus automatic function to protect the unit mechanism from a possible excessive electric current Th...

Страница 24: ...rder to remove select a lower pH level 1or 2 There is no initial smell but after about 1 hour the dispensed water starts to smell Contamination is added into the bottle when collecting water from the...

Страница 25: ...ap water supply by turning on off Operation Knob Electrolysis Method Continuous Electrolysis Levels 4 Alkaline Neutral 2 Acidic Output Rate Max 3 Liters per minute alkaline acidic water Cleaning Devic...

Страница 26: ...the purchasing date 2 Warranty Exceptions 1 Expiration of warranty terms 2 Defect caused by natural disaster such as fire gas accident abnormal voltage flow earthquake thunder etc 3 Disorder or damage...

Страница 27: ...UNIT CONVERSION TABLES 0 1 0 13 0 14 17 0 18 30 0 35 10 0 11 0 77 0 F 0 13 U S gal 0 15 U S gal 0 18 U S gal 0 21 U S gal 0 23 U S gal 0 26 U S gal 0 29 U S gal 0 31 U S gal 0 34 U S gal 1 4 1 5 1 6 1...

Страница 28: ...water may leakfromthe wateroutlethosesonce a unitis installed Water used for quality tests at the factory mayremaininsideof the unit iii Bf ALKAMEDI CO LTD BavlaS4ey 601 602 ho 2 ho 266 Hag Marketed...

Отзывы: