background image

 

Instructions for Use for KardiaMobile Card (AC-021) 

 

 

 

 

 

 

 

 

 

 

 

Page 5 of 17 

 

4.  Do not use this device to diagnose heart-related conditions.  
5.  KardiaMobile Card does not check for heart attack. 
6.  Detection of possible Atrial Fibrillation (AF) in your EKG results are not to be used for 

diagnosis. 

7.  Result of "Bradycardia" or "Tachycardia" are designations of heart rate in the absence of AF, 

and are not to be used for diagnosis.  Please consult with your physician should you receive 
consistent identifications of "Bradycardia" or "Tachycardia". 

8.  “Unreadable” EKG result determines that you didn't have proper EKG recording for analysis. 

You may try to re-record your EKG. 

9.  Do not use to self

-

diagnose heart related conditions. Consult with your physician before 

making any medical decision, including altering your use of any drug or treatment. Do not 
change or adjust your medication without talking to your doctor. 

10. Do not continue use until further instructed by a physician if your skin is irritated or inflamed 

around the electrode contact area. 

11. AliveCor makes no warranty for any data or information that is collected erroneously by the 

device, or misuse or malfunction as a result of abuse, accidents, alteration, misuse, neglect, 
or failure to maintain the products as instructed. Interpretations made by this device are 
potential findings, not a complete diagnosis of cardiac conditions. All interpretations should 
be reviewed by a medical professional for clinical decision-making. 

12. The device has not been tested for and is not intended for pediatric use. 
13. Device contains a lithium manganese dioxide battery that is not removable or replaceable. 
14. Do not use the electrode on a portion of the body with too much body fat, body hair or very 

dry skin, as a successful recording may not be possible. 

15. Do not take a recording while driving or during physical activity. 
16. Do not store in extremely hot, cold, humid, wet, or bright conditions. 
17. Do not take a recording if electrodes are dirty. Clean them first (see cleaning instructions 

under “Maintenance” section). 

18. Do not use abrasive cleaners and materials as these products could adversely affect 

product performance. 

19. Do not immerse device or expose device to excessive liquid. 
20. Do not use while charging your phone. 
21. Do not drop or bump with excessive force. 
22. Do not expose to strong electromagnetic fields. Do not take recordings when the device is in 

close vicinity to strong electromagnetic fields (e.g. electromagnetic anti-theft systems, metal 
detectors). 

23. Do not expose the device to a magnetic resonance (MR) environment.  
24. Do not use with a cardiac pacemaker, ICDs, or other implanted electronic devices. 
25. Do not use during a medical procedure (e.g. magnetic resonance imaging, diathermy, 

lithotripsy, cautery and external defibrillation procedures). 

26. Do not place electrodes in contact with other conductive parts including earth. 
27. Do not use with un-approved accessories. Use of non-AliveCor approved accessories or 

transducers and cables could result in electromagnetic emissions or decreased 
electromagnetic immunity of this device and result in improper operation. 

Содержание AC-021

Страница 1: ...trademarks of AliveCor Inc in the United States and other jurisdictions Instructions for Use IFU for KardiaMobile Card AC 021 21LB01 01 December 2021 AliveCor Inc 189 N Bernardo Avenue Suite 100 Moun...

Страница 2: ...ionality 6 Setting up your KardiaMobile Card device for the first time 7 Recording an EKG 7 EKG Analysis 8 Heart Rate 10 Environmental Specifications 10 Expected Service Life 10 Maintenance 10 Device...

Страница 3: ...your heart rhythm is provided upon completion of your EKG recording See the EKG Analysis section for more details 4 KardiaMobile Card requires a compatible smartphone or tablet and the Kardia app a T...

Страница 4: ...ny EKG result including normal You should notify your physician for possible changes in your health or if you are experiencing any concerning symptoms 2 Chest pain or pressure is a medical emergency H...

Страница 5: ...making 12 The device has not been tested for and is not intended for pediatric use 13 Device contains a lithium manganese dioxide battery that is not removable or replaceable 14 Do not use the electr...

Страница 6: ...ard System is intended for use by healthcare professionals patients with known or suspected heart conditions and health conscious individuals The device has not been tested and is not intended for ped...

Страница 7: ...evice list at www alivecor com compatibility 3 Make sure Bluetooth is turned on in your smartphone or tablet settings 4 Launch the Kardia app and tap Create Account 5 Follow the on screen instructions...

Страница 8: ...G recording is complete 8 The device will turn off automatically after use EKG Analysis Upon completion of your EKG recording the EKG is processed by AliveCor s Instant Analysis algorithms in the Kard...

Страница 9: ...recordings shorter than 30 seconds Record a new EKG Try to relax and hold still rest your arms or move to a quiet location that will allow for a full 30 second recording Unclassified Atrial fibrillat...

Страница 10: ...favorably compared to Lead I recordings of a standard FDA cleared 12 lead device Clinical equivalence of recordings from these Kardia devices and the 12 lead EKG device were also validated by board c...

Страница 11: ...ces KardiaMobile Card has been tested and deemed in conformance with the relevant requirements in IEC 60601 1 2 2014 Class B for Electromagnetic Compatibility EMC FCC and Industry Canada IC Compliance...

Страница 12: ...s open the KardiaMobile Card device is selected and is ready to pair Make sure the amber LED light turns on when you press the white power button located inside the A symbol on the right corner of the...

Страница 13: ...recording Ensure that the Enhanced Filter is on Make sure Mains Filter is set appropriately for your geographical location This can be adjusted under the Kardia app Settings 3 On my EKG the recording...

Страница 14: ...immunity KardiaMobile Card is intended for use in the electromagnetic environment specified below The customer or the user of KardiaMobile Card should assure that it is used in such an environment Im...

Страница 15: ...as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symb...

Страница 16: ...ated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1...

Страница 17: ...Symbol Interpretation Manufacturer Refer to instruction manual booklet Read instructions before use Do not dispose with household waste Temperature range Do not cut shred or attempt to destroy device...

Отзывы: