21
ADJUSTMENT
1) Required Test Equipment
The following items are required to adjust radio parameters:
1. Regulated power supply
Supply voltage:
5-14V DC
Current:
3A or more
2. Digital multimeter
Voltage range:
FS = Approx. 20V
Current:
10A or more
Input resistance:
High impedance
3. Oscilloscope
Measurable frequency:
Audio frequency
4. Audio dummy load
Impedance:
8
Ω
Dissipation:
1W or more
Jack:
3.5mm
Φ
5. SSG
Output frequency:
200MHz or more
Output level:
-20dBu/0.1uV -120dBu/1V
Modulation:
FM
6. Spectrum Analyzer
Measuring range:
Up to 2GHz or more
7. Power meter
Measurable frequency:
Up to 200MHz
Impedance:
50
Ω
, unbalanced
Measuring range:
0.1W -10W
8. Audio volmeter
Measurable frequency:
Up to 100kHz
Sensitivity:
1mV to 10V
9. Audio generator
Output frequency:
67Hz to 10kHz
Output impedance:
600
Ω
, unbalanced
10.Distortion meter/SINAD meter
Measurable frequency:
1kHz
Input level:
Up to 40dB
Distortion:
1% - 100%
11.Frequency counter
Measurable frequency:
Up to 200MHz
Measurable stability:
Approx. +/-0.1ppm
Содержание DJ-195
Страница 2: ......
Страница 11: ...10 3 M5222FP 600C XA0385 Electronic Volume ...
Страница 12: ...11 4 TK14521MTL XA0515 IF System ...
Страница 14: ...13 8 S 81250SG QD T1 XA0619 Top View 9 S 80845ALMP EA9 T2 XA0620 Voltage Regulator ...
Страница 16: ...15 EXPLODED VIEW 1 Front View www ALIMCO ru ...
Страница 17: ...16 2 Rear View ...
Страница 28: ......
Страница 29: ...27 PC BOARD VIEW MAIN SIDE A MAIN Side B ...
Страница 30: ...28 SCHEMATIC DIAGRAM ...
Страница 31: ...29 BLOCK DIAGRAM www ALIMCO ru ...
Страница 32: ......
Страница 33: ......