background image

User Manual for ST School Milk Cooler 

Beverage-Air

Rev. 06/20

Beverage-Air

20

LIMITED WARRANTY

WARRANTY (Warranty valid in USA and Canada)

THREE (3) YEAR PARTS AND LABOR WARRANTY: 

Beverage-Air Corporation warrants to the original 
purchaser of Beverage-Air branded equipment, including 
all parts thereof, that such equipment is free from defects 
in material and workmanship, under normal use, proper 
maintenance, and service as indicated by Beverage-Air 
installation and operation instructions, for a period of three 
(3) years from the date of installation, or thirty-nine (39) 
Months from the date of shipment from the manufacturer, 
whichever is earlier.

ADDITIONAL FOUR (4) YEAR COMPRESSOR PART 
WARRANTY*:  In addition to the warranty set forth above, 
Beverage-Air warrants the hermetically/semi-hermetically 
sealed compressor (part only) for an additional FOUR (4) 
years beyond the first three (3) years warranty period; 
not to exceed eighty-seven (87) months from the date of 
shipment from Beverage-Air, provided upon receipt of the 
compressor, manufacturer examination shows the sealed 
compressor to be defective. This extended warranty does 
not cover freight for the replacement compressor or freight 
for the return of the failed compressor. 

* Units shipped after 03/01/2020.  Previous warranty 
applies to units shipped prior.   

EXCEPTIONS:

CT96 Models carry a one (1) year parts and labor warranty, 
limited to fifteen (15) months from date of shipment 
from Beverage-Air.  These are excluded from additional 
compressor warranty.   

SR/SF (Slate) models carry a two (2) year parts and labor 
warranty, limited to twenty-seven (27) months from date of 
shipment from the Beverage-Air. 

Blast Chillers carry a three (3) year parts and labor 
warranty; additional two (2) years compressor part only. 

Units installed in Residential applications will be not 
covered under this warranty.  Units are intended for 
Commercial use only.         

                                                                        

BEVERAGE-AIR 

Also, this extended compressor-part only warranty does 
NOT apply to any electrical controls, condenser, evaporator, 
fan motors, overload switch, starting relay, capacitors, 
temperature control, filter/drier, accumulator, refrigeration 
tubing, wiring harness, labor charges, or supplies which are 
covered  by  the  warranty  above.                                                                                                                     

Normal wear type parts, such as light bulbs/lamps and 
gaskets are not covered by this warranty. For the purpose 
of this warranty, the original purchaser shall be deemed to 
mean the individual or company for who the product was 
originally installed.

Our obligation under this warranty shall be limited to 
repairing or replacing, including labor, any part of such 
product, which proves thus defective. Beverage-Air 
reserves the right to examine any product claimed to be 
defective.

The labor warranty shall be for self-contained units 
only and for standard straight time, which is defined as 
normal service rate time, for service performed during 
normal working hours. Any service requested outside of 
a servicer's normal working hours will be covered under 
this warranty at the normal rate and any additional 
overtime rate will be at the responsibility of the equipment 
purchaser.

Any part or accessory determined to be defective in the 
product should be returned to the company within thirty 
(30) days under the terms of this warranty and must be 
accompanied by a record of the cabinet model, serial 
number, and identified with a return material authorization 
number (RMA#) issued by the manufacturer.

Special installation/applications, including remote locations, 
are limited in coverage by this warranty. Any installation 
that requires extra work, and/or travel, to gain access to the 
unit for service is the sole responsibility of the equipment 
purchaser.

Improper operation resulting from factors, including but not 
limited to, improper or negligent cleaning and maintenance, 
low voltage conditions, inadequate wiring, outdoor use 
(unless otherwise specified) and accidental damage are no 
manufacturing defects and are strictly the responsibility of 
the purchaser.

Содержание BEVERAGE-AIR ST Series

Страница 1: ...NG INSTRUCTIONS for all Hydrocarbon ST School Milk Cooler Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 187A 6 27 2020 SEE BACK COVER FO...

Страница 2: ...ated with this manual Please complete the card and submit it to Beverage Air within TEN days of installation Failure to properly register equipment may limit or void the warranty Beverage Air reserves...

Страница 3: ...ingers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other...

Страница 4: ...iability for units that have been altered in any way Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be...

Страница 5: ...47 ST49HC 49 x 31 1 4 x 41 1 8 Solid 3 7 R 290 75 2 65 ST58HC 58 x 31 1 4 x 41 1 8 Solid 3 7 Height includes casters PRODUCT INFORMATION All models will maintain product temperature between 35 5 and...

Страница 6: ...d Top 0 Left 0 Right 0 Rear 4 5 8 Below Floor Load the floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the u...

Страница 7: ...ully make one continuous cut to the bottom of the skid Remove cardboard carton and discard 3 Then move unit as close to final position as possible before removing the skid 4 Move unit as close to fina...

Страница 8: ...f the power cord becomes damaged it must be replaced with the identical cord Follow All National and Local Codes This Unit Must Be Grounded Do not use extension cords and do not disable or by pass gro...

Страница 9: ...nually defrost your milk cooler 1 Remove the product from your milk cooler and place it in another refrigerated storage area 2 Open the lids and doors of your milk cooler and unplug the power to the u...

Страница 10: ...essor Contact is energized Compressor turns off when the air temperature at probe is equal to or less than the set point 2 The Compressor Contact is de energized ERC 112 Terminal 1 ERC 112 Terminal 1...

Страница 11: ...ress and release Increases Set Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ES...

Страница 12: ...Panel Connections Changing the Set point Electronic Controller Alarms The alarm condition is always signaled by the alarm icon To turn off the relative icon will continue flashing NOTE If alarm exclus...

Страница 13: ...relay beep the buzzer Door open alarm uHi Line voltage is higher than Cop uHi Always Blink uHi If configu red cut in alarm relay beep the buzzer High voltage alarm uLi Line voltage is higher than Cop...

Страница 14: ...air dry 6 Restore power 7 Return food to the unit when it has reached a safe temperature Defrosting ST units must be manually defrosted periodically Cold Wall units like the SM and ST maintain the ai...

Страница 15: ...emove the Phillips head screws on the left and right of the rear panel 3 Pull the panel away from the unit 4 Brush off the surface of the condenser fins Do NOT bend the fins 5 Vacuum the surface of th...

Страница 16: ...small amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Di...

Страница 17: ...nician No cooling compressor does not hum Temp control stuck in open position Replace temp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure...

Страница 18: ...in an area free from flame or spark It must also be in a well ventilated area with a nearby open window or door A sign noting service of a system containing propane must be attached to the unit durin...

Страница 19: ...erage Air Rev 06 20 Beverage Air 19 FOR THE SERVICE TECH WIRING DIAGRAM CNTRL 3 2 1 2 M 1 CURRENT RELAY S S R OL C CONDENSER FAN COMP COMPRESSOR DETAIL 115V 1PH WHITE BLACK BLACK WHITE SEE CONTROLLER...

Страница 20: ...ERAGE AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filte...

Страница 21: ...RT AND WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall n...

Страница 22: ..._______________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name ___________________________________________...