CLEANING  AND MAINTENANCE

Cleaning Schedule: 
Cabinet

Daily wipe down

Weekly interior

Condenser coil

Quarterly cleaning

Gaskets

Daily inspection

Routine maintenance

Annually

Daily Exterior Cleaning

It is much easier to clean on a regular basis than to have to remove stains once they have built up.

1.  Wash with a clean sponge and a mild detergent that 

does not contain chlorine.

2.  Rinse with clean water.

3.  Dry with a soft cloth.

4.  Polish with a soft cloth, wiping with the grain.

5.  Wipe weekly with stainless steel cleaner.

Weekly Interior Cleaning

1.  Remove all food, food related items. Store the food at 

a safe temperature.

2.  Disconnect power to the unit (unplug it or switch the 

breaker off).

3.  Remove all loose food particles from the inside walls, 

floor, door liner and ceiling.

4.  Scrub all interior surfaces and door gaskets with a 

warm (100

o

F to 110

o

F) detergent solution and a soft 

scrub brush.

5.  Rinse with clean water and allow to air dry.

6.  Restore power.

7.  Return food to the unit when it has reached a safe 

temperature.

Defrosting

ST units must be manually defrosted periodically. “Cold 
Wall” units like the SM and ST maintain the air temperature 
of the cabinet at the set point by cooling the walls below 
the set point to approximately 20°F. Because the walls of 
the cooler are below the freezing temperature of water, 
ice may build up over time. It is important to occasionally 
manually defrost the unit to minimize ice build-up.

To manually defrost your milk cooler:

1.  Remove the product from your milk cooler and place it 

in another refrigerated storage area.

2.  Open the lids and doors of your milk cooler and unplug 

the power to the unit.

3.  Wait approximately 30 min for the frost to melt and 

drain to the floor drain. Times may vary with ambient 
temperature in the room and ice build-up.

WARNING: DO NOT SCRAPE THE WALLS TO SPEED UP 
DEFROSTING. SCRAPING MAY RUIN SURFACE FINISH OR 
PUNCTURE WALL AND DAMAGE REFRIGERATION TUBING 
BEHIND THE WALL 

4.  After manual defrost, Close the lid and doors and power 

the unit by plugging it into the outlet. Return product to 
the cooler after the air in the cabinet has cooled to the 
desired temperature.

Содержание BEVERAGE-AIR ST Series

Страница 1: ...NG INSTRUCTIONS for all Hydrocarbon ST School Milk Cooler Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 187A 6 27 2020 SEE BACK COVER FO...

Страница 2: ...ated with this manual Please complete the card and submit it to Beverage Air within TEN days of installation Failure to properly register equipment may limit or void the warranty Beverage Air reserves...

Страница 3: ...ingers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other...

Страница 4: ...iability for units that have been altered in any way Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be...

Страница 5: ...47 ST49HC 49 x 31 1 4 x 41 1 8 Solid 3 7 R 290 75 2 65 ST58HC 58 x 31 1 4 x 41 1 8 Solid 3 7 Height includes casters PRODUCT INFORMATION All models will maintain product temperature between 35 5 and...

Страница 6: ...d Top 0 Left 0 Right 0 Rear 4 5 8 Below Floor Load the floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the u...

Страница 7: ...ully make one continuous cut to the bottom of the skid Remove cardboard carton and discard 3 Then move unit as close to final position as possible before removing the skid 4 Move unit as close to fina...

Страница 8: ...f the power cord becomes damaged it must be replaced with the identical cord Follow All National and Local Codes This Unit Must Be Grounded Do not use extension cords and do not disable or by pass gro...

Страница 9: ...nually defrost your milk cooler 1 Remove the product from your milk cooler and place it in another refrigerated storage area 2 Open the lids and doors of your milk cooler and unplug the power to the u...

Страница 10: ...essor Contact is energized Compressor turns off when the air temperature at probe is equal to or less than the set point 2 The Compressor Contact is de energized ERC 112 Terminal 1 ERC 112 Terminal 1...

Страница 11: ...ress and release Increases Set Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ES...

Страница 12: ...Panel Connections Changing the Set point Electronic Controller Alarms The alarm condition is always signaled by the alarm icon To turn off the relative icon will continue flashing NOTE If alarm exclus...

Страница 13: ...relay beep the buzzer Door open alarm uHi Line voltage is higher than Cop uHi Always Blink uHi If configu red cut in alarm relay beep the buzzer High voltage alarm uLi Line voltage is higher than Cop...

Страница 14: ...air dry 6 Restore power 7 Return food to the unit when it has reached a safe temperature Defrosting ST units must be manually defrosted periodically Cold Wall units like the SM and ST maintain the ai...

Страница 15: ...emove the Phillips head screws on the left and right of the rear panel 3 Pull the panel away from the unit 4 Brush off the surface of the condenser fins Do NOT bend the fins 5 Vacuum the surface of th...

Страница 16: ...small amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Di...

Страница 17: ...nician No cooling compressor does not hum Temp control stuck in open position Replace temp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure...

Страница 18: ...in an area free from flame or spark It must also be in a well ventilated area with a nearby open window or door A sign noting service of a system containing propane must be attached to the unit durin...

Страница 19: ...erage Air Rev 06 20 Beverage Air 19 FOR THE SERVICE TECH WIRING DIAGRAM CNTRL 3 2 1 2 M 1 CURRENT RELAY S S R OL C CONDENSER FAN COMP COMPRESSOR DETAIL 115V 1PH WHITE BLACK BLACK WHITE SEE CONTROLLER...

Страница 20: ...ERAGE AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filte...

Страница 21: ...RT AND WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall n...

Страница 22: ..._______________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name ___________________________________________...

Отзывы: