ASDI
Installation, Operation and Maintenance Manual
– SECOND SUN – P/N 51856
19
Figure 11:
Adjustable pressure switch settings
The adjustable pressure switch is pre-set to 55 psi, unless specified by the customer to a different
setting.
Every 60 degrees of counter-clockwise rotation (one wrench flat) will
increase
the pressure setting by
30 psi.
Every 60 degrees of clockwise rotation (one wrench flat) will
decrease
the pressure setting by 30 psi.
OUT OF ADJUSTMENT
No threads exposed:
Rotate switch body
counterclockwise until one
thread is visible outside the
lock ring.
PROPER ADJUSTMENT
One exposed thread:
Pressure setting is factory pre-
set at 55 psi.
OUT OF ADJUSTMENT
Multiple threads exposed:
Rotate the switch body
clockwise until only one thread
is visible outside the lock ring
and marks are aligned.
Indicator marks on wrench flat and
switch body show factory pre-set
mark alignment at 55psi.