Installation
Algas-SDI Operation and Maintenance Manual - SH100-SH200
2-7
Burner Mounting
Mount the burner to the chamber wall using customer
supplied
M10 X 1.5mm bolts (4X) and M10 lock washers (4X).
Verify the gasket that was supplied with the burner is
installed between the burner and the chamber wall.
Verify the gasket does not leak.
To ensure that radiated heat doesn’t reach the exterior of the
chamber, insulate the combustion tube over the length
contained within the chamber wall filling and clearance
completely. If the firing tube extends beyond the chamber
wall thickness, DO NOT insulate the exposed end of the
tube.
Figure 2.3 –
Alloy Combustor Chamber Mounting