15
DPT-EN3 Connections
BINDER 720 Self-Latching Push Pull Connector
(Connector
Included with DPT-EN3)
The image above illustrates the Self-Latching Push Pull Connector and
cable used between the DPT-EN3, and the Relay, Siren or Bell. A
5.0 m
USB Cable
is also included as standard with the DPT-EN3.
Physical Layout and Dimensions
DPT-EN3
all Dimensions in mm
Wall mounted Clip-on Bracket
A Wall mounted Clip-on bracket is provided with your DPT-EN3. This
bracket can be securely attached to the wall by drilling two 6 mm holes
spaced 40 mm vertically into the wall. Insert the two wall-mount plugs
(included as standard with the DPT-EN3) into the 6 mm holes and
screw the bracket securely onto the wall.
Relay contacts
between
pin 1 and 2.
16
Relay contacts
between pin 1 and 2.
Installing the DPT-EN3
Always refer to the SAFETY INSTRUCTIONS found in this manual.
The timer must only be installed by qualified service personnel.
1. Remove the timer from its packaging and disassemble the Bender
Series 720 Connector.
1.1 A Ø 5.3 mm – 6.5 mm cable is recommended. Strip the
electrical cable as illustrated below.
Solder Tin the Conductors
g
.
1.2 Slide the Collet Nut
c
and then the Collet
d
, Seal
e
and
Sleeve
f
onto the Cable. Note the location of Pin # 1 and 2 as
illustrated
i
, and solder the cable's conductors
g
only into
Pin # 1 and 2 of the contacts
g
of the Insulator
h
.
1.3 Push the Sleeve
f
forward and tighten it securely against the
Insulator
h
. Slide the Collet Nut
c
over the Collet
d
and
tighten securely against the Seal
e
and Sleeve
f
.
2. If the unit is wall mounted, drill the holes in the wall, using a 6 mm
(± ¼") drill. Insert the plugs & screws provided to mount the Wall-