7
Igniter Cap
Igniter Module
Battery - 9 Volt
Point contacts
towards module
Figure # 1
Remove grease tray !
(Bottom view)
GAS CONNECTION—LIQUID PROPANE (LP)
NEVER CONNECT THE VERSAPOWER™ COOKING SYSTEM
TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury. Total gas consumption (per hour) with all
burners set on “HI” is a follows:
Center Burner
20,000 BTU
Perimeter Burner
45,000 BTU
65,000 BTU
Total gas consumption.
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1988. Installation in Canada must be in accordance with the
Standard CAN/ CGA-B149.1 Natural Gas Installation or CAN/CGA-B149.2, Propane Installation Code.
Manifold pressure with LP
Operating: 10.0” W.C.
Non-operating:
11.2” W.C.