NOISY OPERATION: 
 

• 

AMBIENT TEMPERATURE: 

Is the ambient temperature about 90°F or above?  The unit will 

need to run more at these elevated temperatures, therefore you will become more aware of 
sound generated by the compressor and the fans. 

 

• 

REQUIRED RUN TIME:

 Is the unit running continuously for long periods of time?  As the 

ambient temperature rises, the refrigerator requires more cooling, therefore sound from the 
compressor and fans will become more noticeable.

 

 

• 

RESIDUAL HEAT:

 Is the unit located outdoors on a concrete or paved slab, or in a sunny 

area?  Residual heat present in the concrete or paving will raise the temperature of the intake 
air entering the front of the unit.  Consequently, the air moving through the condenser coil may 
be relatively hot and therefore less efficient at cooling, causing the unit to run longer in order to 
maintain the proper refrigerating capacity.

 

 

• 

DEBRIS IN THE FAN BLADES:

 Is there debris in the condenser fan blades?  Not only can 

debris physically stop the fan from rotating (as previously discussed), it can also block or 
restrict air flow, thus preventing the unit from cooling.  The fan blades may, in some cases, 
continue to rotate, causing a rattling or similar sound as the blades contact debris trapped in 
close proximity to the fan.

 

 

• 

FULLY STOCKED:

  is the unit fully stocked?  If the unit is not fully stocked, or only partially 

filled, then the unit will need to work harder.  Air does not hold temperature, products do.  If 
there is no product inside the refrigerator, the unit will cycle ON and OFF several times per 
hour.  If the unit is fully stocked, the run-time will be extended but also the off-time, allowing 
the compressor to cool down properly between cycles.  This will help the unit to run more 
efficiently.

 

PERFORMANCE ENVELOPE: 
 

The ARDI has a performance envelope up to 110°F ambient temperature.  This means that the 
unit is capable of maintaining an internal cabinet temperature of between 22°F and 40°F when 
exposed to 110°F ambient air temperature.  In order to maintain the internal cabinet temperatures 
stated above, the unit will operate without shutting off when the ambient air temperature exceeds 
85 to 90°F  These peak temperatures occur at least for a few hours per day in hot weather 
locations and should be considered normal.  The unit will return to normal cyclic operation after 
the ambient air temperature falls back below 85 to 90°F.  Please note, ambient air temperature is 
a complex measurement to establish, especially outdoors.  Your local weather forecaster, when 
reporting current conditions, will be referring to a temperature measured in a shaded and 
ventilated box located at least four feet above the ground.  If the reported temperature is 100°F, 
and your unit is sat on a concrete slab in full sunlight, then the ambient temperature around your 
unit will be substantially higher than the reported 100°F. 

Содержание ARDI

Страница 1: ...File name ARDI Service Manual pub Last revised March 6th 2009 ARDI SERVICE AND PARTS MANUAL ...

Страница 2: ...as been tripped If the latter is the case then switching the unit off for fifteen minutes then on again should solve the problem CONDENSER FAN NOT RUNNING Is the compressor running but not the condenser fan If the compressor is running then the condenser fan should be running Verify that power is being supplied to the fan motor and that the fan blades rotate freely Check for debris leaves paper gr...

Страница 3: ...fully stocked or only partially filled then the unit will need to work harder Air does not hold temperature products do If there is no product inside the refrigerator the unit will cycle ON and OFF several times per hour If the unit is fully stocked the run time will be extended but also the off time allowing the compressor to cool down properly between cycles This will help the unit to run more e...

Страница 4: ...it Please refer to the picture and associated text for reference and identification Condensing Unit 260 0104 Drier 220 0030 Sight Glass 220 0014 REFRIGERANT COMPRESSOR 260 0055 CAPACITOR 210 0393 RELAY 210 0392 SAFETY OVERLOAD 210 0391 NOTE PART NUMBERS 210 0391 210 0392 AND 210 0393 ARE REPLACEMENT PARTS FOR THE COMPRESSOR ASSEMBLY ...

Страница 5: ...RDI SERVICE PARTS LIST CONTINUED Main Power Switch 210 0021 Power Cord 210 0287 Strain Relief 200 0009 Used to secure power cord Refrigerator Control 210 0551 Food Pan 1 6 x 4 290 0162 Pan Holder 130 1043 ...

Страница 6: ...6 ...

Страница 7: ...scription of the problem The model number and serial number can be found on a plate located either on the underside of the top cover or on the body behind the removable louvered front panel REFRIGERATION REFRIGERANT 134A 13OZ SUCTION PRESSURE TEMP 18 PSI 20 F ACCEPTABLE RANGE 12 21 PS I COIL TEMP 10 F 24 F LIQUID PRESSURE TEMP 125 PSI 100 F ACCEPTABLE RANGE 125 147 PSI AMBIENT TEMP 80 F 90 F 170 P...

Отзывы: