7
ARDI SERVICE DATA:
ELECTRICAL:
•
VOLTAGE: 115 VAC
•
FREQ: 60 Hz
•
PHASE: 1
•
AMPS: 6.0
•
RLA: 5.3
•
LRA: 29.0
•
MCA: 7.0
FOR SERVICE, CALL: 1 866 203 5607
When calling, please provide the following information: model number, serial
number and date of installation, along with a brief description of the problem. The
model number and serial number can be found on a plate located either on the
underside of the top cover or on the body behind the removable louvered front
panel.
REFRIGERATION:
REFRIGERANT 134A (13OZ)
SUCTION PRESSURE @ TEMP.
18 PSI @ 20°F
ACCEPTABLE RANGE: 12 - 21 PS I (COIL TEMP. 10°F - 24°F)
LIQUID PRESSURE @ TEMP.
125 PSI @ 100°F
ACCEPTABLE RANGE: 125 - 147 PSI (AMBIENT TEMP. 80°F - 90°F)
170 PSI @ 120°F
ACCEPTABLE RANGE: 170 - 197 PSI (AMBIENT TEMP. 100° - 110°F)